Additional information : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
Additional information : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
author: Kirsten W Slagter, Gerry M Raghoebar, Arjan Vissink, Henny J A Meijer | publisher: drg. Andreas Tjandra, Sp. Perio, FISID
Kirsten W. Slagter, Gerry M. Raghoebar, Arjan Vissink, Henny JA. Meijer declare that they have no competing interests.
KWS, GMR, AV, and HJAM provided substantial contributions to the conception or design of the work, or the acquisition, analysis, or interpretation of data for the work; drafted the paper or revised it critically; gave final approval of the version to be published; and agreed to be accountable for all aspects of the work in ensuring that questions related to accuracy or integrity of any parts of the work are appropriately investigated and resolved. All authors read and approved the final manuscript.
Serial posts:
- Abstract : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Background : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Methods : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region [1]
- Methods : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region [2]
- Results : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Discussion : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Conclusions : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Abbreviations : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- References : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region [1]
- References : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region [2]
- Author information : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Additional information : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Rights and permissions : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- About this article : Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region
- Figure 1. Clinical photograph of implant-supported restoration at position 21. : Inter- and intraobserver reproducibility of buccal bone measurements at dental implant
- Figure 2. Conventional intra-oral radiograph of same patient with implant-supported restoration at position 21. : Inter- and intraobserver reproducibility of buccal bone measurements at dental implant
- Figure 3. Implant position. Due to the alienation of the patients’ DICOM files by MIRIT, the exact position of the implant was defined. As such, the measurements could take place in the exact correct buccal direction. : Inter- and intraobserver reproducibility of buccal bone measurements at dental implant
- Figure 4. Implant measurements. Measurements were performed at each millimeter along the axis of the implant for 5 mm, beginning at the neck of the implant. : Inter- and intraobserver reproducibility of buccal bone measurements at dental implant
- Figure 5. Flow diagram of CBCT imaging and measurements to calculate bone thickness buccally of implants. : Inter- and intraobserver reproducibility of buccal bone measurements at dental implant