Background : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [2]
Both multislice CT and cone beam CT are used for presurgical assessment of bone density and quality [4,5,6,7,8,9,10,11]. There is a strong correlation between gray values in cone beam CT and Hounsfield units in multislice CT [4, 12,13,14]. The visual inspection of CT sections avoids the superimposition of anatomical structures seen in radiographs; thus, the region of interest in trabecular bone can be evaluated without the interference of cortical bone. Positive associations of primary stability with bone density [15], bone volume [16], and thickness of the cortical bone [17] have been reported. If it were possible to accurately relate bone quality measures with primary implant stability, the surgical, prosthetic, and loading planning could be more precise and predictable.
Therefore, this study aimed at assessing the relationship between insertion torque and bone quality evaluated by intra-surgical tactile perception and in preoperative CT images analyzed either visually or by rescaled mean gray values. The association among the subjective and objective measures of bone quality also was tested. The null hypothesis is that there is no relation between insertion torque, visual, and rescaled gray values of the bone in this sample of short implants.
Serial posts:
- Abstract : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Background : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [1]
- Background : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [2]
- Methods : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [1]
- Methods : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [2]
- Methods : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [3]
- Methods : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [4]
- Results : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Discussion : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [1]
- Discussion : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [2]
- Discussion : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [3]
- Conclusions : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Abbreviations : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- References : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [1]
- References : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [2]
- References : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [3]
- Acknowledgements : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Author information : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [1]
- Author information : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants [2]
- Ethics declarations : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Rights and permissions : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- About this article : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Table 1 Descriptive statistics of the sample : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Table 2 Matrix of Spearman correlation coefficients and P values (in brackets) for the association among assessment methods of bone quality (intra-surgical tactile perception, preoperative CT visual evaluation, preoperative CT mean gray values (MGVs)) and primary stability (insertion torque) : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Table 3 Comparison of CT mean gray values (average of the axial, coronal, and sagittal ROIs) as a function of arch, dental region, insertion torque, and bone types as classified by CT visual assessment and by intra-surgical tactile evaluation : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
- Fig. 1. Clinical case of a short implant (4.1 × 6 mm) placed in the region of the left maxillary first molar. a Implant installed. b Insertion torque measurement using the manual torque wrench. c Implant with healing cap and flap suture. d Immediate periapical radiograph after surgery : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implant
- Fig. 2. Preoperative CT image showing the site for the definition of the ROI (simulated area delimited by a yellow dashed line for illustration purpose) in the axial (a), coronal (b), and sagittal (6 × 6 mm) (c) sections : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implant
- Fig. 3. One possible missing category (depicted as “X”) would be a bone type with thick cortical layer and sparse trabecular bone, which would have intermediate characteristics and behavior between the types with thick (2) or thin (3) cortical bones : Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implant