References : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [2]
Morrison A, Chiaro M, Kirby S. Mental nerve function after inferior alveolar nerve transposition for placement of dental implants. J Can Dent Assoc. 2002;62:46–50.
Vetromilla BM, Moura LB, Sonegi CL, et al. Complications associated with inferior alveolar nerve repositioning for dental implant placement: a systematic review. Int J Oral Maxillofac Surg. 2014;43(11):1360–6.
Eggers G, Klein J, et al. Piezosugery: an ultrasound device for cutting bone and its use and limitations in maxillofacial surgery. Br J Oral Maxillofac Surg. 2004;42:451–3.
Stubinger S, Kuttenberger J, et al. Intraoral piezosurgery: preliminary results of a new technique. J Oral Maxillofac Surg. 2005;63:1283–7.
Sakkas N, Otten JE, et al. Transposition of the mental nerve by piezosurgery followed by postoperative neurosensory control: a case report. Br J Oral Maxillofac Surg. 2008;46:270–1.
Lambrecht JT. Intraoral piezo-surgery. Schweiz Monatsschr Zahnmed. 2004;114:28–36.
Akça K, Iplikçioğlu H. Finite element stress analysis of the effect of the short implant usage in place of cantilever extensions in mandibular posterior edentulism. J Oral Rehabil. 2002;29:350–6.
Serial posts:
- Abstract : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Background : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Methods : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Results : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Discussion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [1]
- Discussion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [2]
- Discussion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [3]
- Conclusions : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- References : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [1]
- References : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [2]
- Acknowledgements : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Author information : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Additional information : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Rights and permissions : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- About this article : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Table 1 Highet grading : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Table 2 Results of assessment of sensory neural function after inferior alveolar nerve (IAN) transposition : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Fig. 1. Alveolar nerve repositioning in a partially edentulous mandible. a Preoperative radiograph. b The inferior alveolar nerve was transposed from the mental foramen. c Postoperative radiograph after implant insertion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant
- Fig. 2. a SW perception tester is composed of different diameters (a: 0.165 mm, b: 0.215 mm, c: 0.315 mm). b The use of SW perception tester started from a filament of 0.165 mm in diameter of the most weak force, and performed three times at one site : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant
- Fig. 3. Site of evaluation. (1) Corner of the mouth: 5 mm below the corner of the mouth. (2) Lower lip: 5 mm laterally from the midline. (3) Mental region: at the midpoint of the perpendicular from the lower edge to the lower lip to the chin and 5 mm laterally from the midline : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant