Open hour: senin - sabtu 09:00:00 - 20:00:00; minggu & tanggal merah tutup
Results : Relation between the stability of dental implants and two biological markers during the healing period: a prospective clinical study [1]

Results : Relation between the stability of dental implants and two biological markers during the healing period: a prospective clinical study [1]

author: Choknapa Tirachaimongkol, Peraphan Pothacharoen, Peter A Reichart, Pathawee Khongkhunthian | publisher: drg. Andreas Tjandra, Sp. Perio, FISID

Ten patients, seven females, and three males, aged 42.4 ± 11.99 years (range, 28 to 64 years), with either a first mandibular or second mandibular molar edentulous area, who required a single nonsubmerged implant participated in this study, as shown in Table 2. The implants used for all patients were 10 mm long and 5 mm in diameter. All patients completed the follow-up. None of the implants failed during the study period.

The mean ISQ values were shown in Table 3. There was a statistically significant decrease in the mean ISQ values between 1 and 3 weeks (P < 0.05). The ISQ values recovered to the initial ISQ values at 4 weeks and slight increased at 6, 8, 10, and 12 weeks (Fig. 2). There was a significant increase in the mean ISQ values at 6, 8, 10, and 12 weeks when compared with 3 weeks. The mean lowest ISQ values, recorded at 1 week, were 65.6 ± 2.70. According to the independent samples t test, there were no statistically significant differences in the mean ISQ values with gender and bone quality.

The median values of the GCF and PICF volume are shown in Table 4. At the implant site (test group), the PICF volume continuously decreased with time (Fig. 3). However, according to the Friedman test, there were no significant differences in the median values of the crevicular fluid volume in the control or the test group at each measurement.

Both ALP and OC molecules were detectable in GCF and PICF samples. The median values of the ALP and OC levels are shown in Table 5. In the control group, there was no significant difference in the ALP or the OC levels at each measurement. In the test group (implant site), the ALP level decreased at 1–4 weeks and then increased at 6, 8, 10, and 12 weeks (Fig. 4). However, according to the Friedman test, there was no statistically significant difference in the ALP level of the test group at each measurement. Furthermore, according to the Mann-Whitney U test, there was no statistically significant difference in the ALP level between the control and the test group at each measurement.

Serial posts:


id post:
New thoughts
Me:
search
glossary
en in