References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
Trulsson M, Johansson RS. Encoding of amplitude and rate of forces applied to the teeth by human periodontal mechanoreceptive afferents. J Neurophysiol. 1994;72:1734–44.
Hidaka O, Morimoto T, Masuda Y, Kato T, Matsuo R, Inoue T, et al. Regulation of masticatory force during cortically induced rhythmic jaw movements in the anesthetized rabbit. J Neurophysiol. 1997;77:3168–79.
Hidaka O, Morimoto T, Kato T, Masuda Y, Inoue T, Takada K. Behavior of jaw muscle spindle afferents during cortically induced rhythmic jaw movements in the anesthetized rabbit. J Neurophysiol. 1999;82:2633–40.
Garrett NR, Kapur KK, Hamada MO, Roumanas ED, Freymiller E, Han T, et al. A randomized clinical trial comparing the efficacy of mandibular implant-supported overdentures and conventional dentures in diabetic patients. Part II. Comparisons of masticatory performance. J Prosthet Dent. 1998;79:632–40.
Haraldson T, Jemt T, Stålblad PA, Lekholm U. Oral function in subjects with overdentures supported by osseointegrated implants. Scand J Dent Res. 1988;96:235–42.
Enkling N, Heussner S, Nicolay C, Bayer S, Mericske-Stern R, Utz KH. Tactile sensibility of single-tooth implants and natural teeth under local anesthesia of the natural antagonistic teeth. Clin Implant Dent Relat Res. 2012;14:273–80.
Jacobs R, Van Steenberghe D. From osseoperception to implant-mediated sensory-motor interactions and related clinical implications. J Oral Rehabil. 2006;33:282–92.
Abarca M, Van Steenberghe D, Malevez C, Jacobs R. The neurophysiology of osseointegrated oral implants. A clinically underestimated aspect. J Oral Rehabil. 2006;33:161–9.
Klineberg I, Calford MB, Dreher B, Henry P, Macefield V, Miles T, et al. A consensus statement on osseoperception. Clin Exp Pharmacol Physiol. 2005;32:145–6.
Trulsson M. Sensory and motor function of teeth and dental implants: a basis for osseoperception. Clin Exp Pharmacol Physiol. 2005;32:119–22.
Yan C, Ye L, Zhen J, Ke L, Gang L. Neuroplasticity of edentulous patients with implant-supported full dentures. Eur J Oral Sci. 2008;116:387–93.
Naert I, Alsaadi G, Quirynen M. Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study. Int J Prosthodont. 2004;17:401–10.
Serial posts:
- Background : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- Background : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- Background : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
- Methods : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- Methods : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- Methods : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
- Results : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- Results : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- Discussion : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Conclusions : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [4]
- Acknowledgements : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Author information : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Rights and permissions : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- About this article : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Fig. 1. Correlation between measured Glucosensor value (mg/dl) (the vertical axis) and applied glucose density (mg/dl) (the horizontal axis) in the in vitro setup. A linear regression line could be applied to the data set, and we tested the accuracy of Glucosensor value : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant
- Fig. 2. a Mean and standard deviation (SD) of occlusal contact area at each of the four times. The horizontal label axis was the time stage (1) before implant surgery with the complete denture in situ and (2) right after with provisional implant, (3) 1–2 weeks and (4) 3 months after insertion of the provisional screw-retained restoration, and the label to the vertical axis was contact area (mm2). The occlusal contact area was increased at 3 months after wearing implants (paired t test, p < 0.005). *p < 0.005, significant difference between conditions. b Mean and standard deviation (SD) of bite force at each of the four times. The horizontal label axis was the time stage, and the label to the vertical axis was bite force (N). The approximate maximum bite force was increased at 3 months after wearing implants (paired t test, p < 0.005). *p < 0.005, significant difference between conditions. c Mean and standard deviation (SD) of glucose data at each of the four times. The horizontal label
- Fig. 3. Mean and standard deviation (SD) of percentage of correct answers regarding hardness at each of the four times. The horizontal label axis was the time stage, and the label to the vertical axis was percentage of correct answers regarding hardness (%) : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant