References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
Bakke M, Holm B, Gotfredsen K. Masticatory function and patient satisfaction with implant-supported mandibular overdentures: a prospective 5-year study. Int J Prosthodont. 2002;15:575–81.
Miyaura K, Morita M, Matsuka Y, Yamashita A, Watanabe T. Rehabilitation of biting abilities in patients with different types of dental prostheses. J Oral Rehabil. 2000;27:1073–6.
Peyron MA, Blanc O, Lund JP, Woda A. Influence of age on adaptability of human mastication. J Neurophysiol. 2004;92:773–9.
Habre-Hallage P, Dricot L, Jacobs R, van Steenberghe D, Reychler H, Grandin CB. Brain plasticity and cortical correlates of osseoperception revealed by punctate mechanical stimulation of osseointegrated oral implants during fMRI. Eur J Oral Implantol. 2012;5:175–90.
Jacobs R, van Steenberghe D. Qualitative evaluation of the masseteric poststimulus EMG complex following mechanical or acoustic stimulation of osseointegrated oral implants. Int J Oral Maxillofac Implants. 1995;10:175–82.
Svensson KG, Trulsson M. Impaired force control during food holding and biting in subjects with tooth- or implant-supported fixed prostheses. J Clin Periodontol. 2011;38:1137–46.
Svensson KG, Grigoriadis J, Trulsson M. Alterations in intraoral manipulation and splitting of food by subjects with tooth- or implant-supported fixed prostheses. Clin Oral Implants Res. 2013;24:549–55.
Trulsson M, van der Bilt A, Carlsson GE, Gotfredsen K, Larsson P, Müller F, et al. From brain to bridge: masticatory function and dental implants. J Oral Rehabil. 2012;39:858–77.
Luraschi J, Schimmel M, Bernard JP, Gallucci GO, Belser U, Müller F. Mechanosensation and maximum bite force in edentulous patients rehabilitated with bimaxillary implant-supported fixed dental prostheses. Clin Oral Implants Res. 2012;23:577–83.
Woda A, Foster K, Mishellany A, Peyron MA. Adaptation of healthy mastication to factors pertaining to the individual or to the food. Physiol Behav. 2006;89:28–35.
Heckmann SM, Heussinger S, Linke JJ, Graef F, Pröschel P. Improvement and long-term stability of neuromuscular adaptation in implant-supported overdentures. Clin Oral Implants Res. 2009;20:1200–5.
Gartner JL, Mushimoto K, Weber HP, Nishimura I. Effect of osseointegrated implants on the coordination of masticatory muscles: a pilot study. J Prosthet Dent. 2000;84:185–93.
Serial posts:
- Background : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- Background : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- Background : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
- Methods : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- Methods : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- Methods : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
- Results : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- Results : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- Discussion : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Conclusions : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [1]
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [2]
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [3]
- References : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment [4]
- Acknowledgements : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Author information : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Rights and permissions : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- About this article : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant-supported prosthesis: a pilot assessment
- Fig. 1. Correlation between measured Glucosensor value (mg/dl) (the vertical axis) and applied glucose density (mg/dl) (the horizontal axis) in the in vitro setup. A linear regression line could be applied to the data set, and we tested the accuracy of Glucosensor value : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant
- Fig. 2. a Mean and standard deviation (SD) of occlusal contact area at each of the four times. The horizontal label axis was the time stage (1) before implant surgery with the complete denture in situ and (2) right after with provisional implant, (3) 1–2 weeks and (4) 3 months after insertion of the provisional screw-retained restoration, and the label to the vertical axis was contact area (mm2). The occlusal contact area was increased at 3 months after wearing implants (paired t test, p < 0.005). *p < 0.005, significant difference between conditions. b Mean and standard deviation (SD) of bite force at each of the four times. The horizontal label axis was the time stage, and the label to the vertical axis was bite force (N). The approximate maximum bite force was increased at 3 months after wearing implants (paired t test, p < 0.005). *p < 0.005, significant difference between conditions. c Mean and standard deviation (SD) of glucose data at each of the four times. The horizontal label
- Fig. 3. Mean and standard deviation (SD) of percentage of correct answers regarding hardness at each of the four times. The horizontal label axis was the time stage, and the label to the vertical axis was percentage of correct answers regarding hardness (%) : Short-term follow-up of masticatory adaptation after rehabilitation with an immediately loaded implant