Methods : Narrow implants (2.75 and 3.25 mm diameter) supporting a fixed splinted prostheses in posterior regions of mandible: one-year results from a prospective cohort study [2]

Methods : Narrow implants (2.75 and 3.25 mm diameter) supporting a fixed splinted prostheses in posterior regions of mandible: one-year results from a prospective cohort study [2]

author: Tommaso Grandi, Luigi Svezia, Giovanni Grandi | publisher: drg. Andreas Tjandra, Sp. Perio, FISID

Primary outcome measures were as follows:

Implant failure: evaluated as implant mobility and removal of stable implants dictated by progressive marginal bone loss or infection. The stability of each implant was measured manually by tightening the abutment screw with a wrench delivering a torque of 20 Ncm. Implant stability assessment was performed at delivery of definitive crowns (3 months after implant placement). After insertion of the definitive restorations, prostheses were not removed to assess clinical mobility of individual implants.

Complications: any biological and prosthetic complication occurred at the implant site during the entire follow-up time were recorded and reported.

Secondary outcome measures were as follows:

Peri-implant marginal bone level changes: evaluated on intraoral radiographs taken with the paralleling technique at implant placement, 6 months and 1 year after loading. All measurements were taken by an independent assessor (LS). Radiographs were scanned, digitized in JPG format, converted to TIFF format with a 600 dpi resolution, and stored in a personal computer. Peri-implant marginal bone levels were measured using Image J 1.42 software (National Institute of Mental Health, MD, USA). The software was calibrated for every single image using the known implant diameter. Measurements of the mesial and distal crestal bone levels adjacent to each implant were made to the nearest 0.01 mm and averaged at patient level and then group level. The measurements were taken parallel to the implant axis. Reference points for the linear measurements were the most coronal margin of the implant collar and the most coronal point of bone-to-implant contact.

Statistical analysis was performed using the statistical package StatView (version 5.01.98, SAS Institute Inc., Cary, NC, USA). Significance was considered at p < 0.05. The paired-samples t test was used to evaluate the bone level changes. The patient was the statistical unit of the analysis. A medical doctor (GG) with expertise in dental biostatistics analyzed the data.