Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
A small longitudinal skin incision just distal to the tibia-femur joint was made. The tibia/femur head was exposed subperiosteally and an osteotomy performed with the delicately placed pilot drill over the entry point and lightly pumped up and down under copius saline irrigation just to enter the cortical bone for the MDIs. This was used for initial bone drilling to depth of 0.5 mm. The 3M™ESPE™ MDI (size 1.8 mm × 10 mm) vial was opened and the body of the implant was firmly grasped with a sterilized locking pliers. The titanium finger driver was attached to the head of the implant. The implant was transferred to the site and rotated clockwise while exerting downwards pressure. This began the self tapping process and was used until noticeable bony resistance encountered when it touched the lower cortical plate. The winged thumb wrench was used for driving the implant deeper into the bone, if necessary. All the animals received one MDI on the head of each tibia or femur. Therefore, total 18 mini dental implants were inserted.
Equal number of comparator implants (size 3.5 mm × 8 mm) were inserted in the other tibia/femur head of the animals after doing the osteotomy according to the manufacturer’s protocol as follows. After mobilizing the mucoperiosteal flap, the 3-mm center punch was used to register a guide for the twist drill. The twist drill was used to establish the axial alignment of the implant and to assist in the guidance of the depth drill. The depth drills were sequentially used to create osteotomy to the subcrestal axial depth of 0.5 mm. The conical reamer was used to develop the conical shape of the implant body and to check the osteotomy depth. A counter-clockwise rotation was used to compress the bone in soft bone. The tap or thread cutter was used for dense bone to create the threads in the osteotomy. The thread cutter’s diameter corresponds to the implant diameter. To engage the implant into the implant placement tool, the square faces on the implant fixture mount were aligned with those on the implant placement tool, then pushed together. Using the handle (finger wheel), the implant was pulled out of inner vial and the plastic collar was discarded. The implant placement assembly was transferred to the osteotomy and the implant was secured into the osteotomy site. The implant placement was started with the handle and finally placed using the hand-ratchet. If excessive force was experienced, the osteotomy was rinsed out and the depth was checked by retapping. To disengage fixture mount from implant, the open-ended spanner was used to break the retention force of the fixture mount retention screw. The knurled top of the implant placement tool was turned by hand to fully disengage the fixture mount with the implant. Pushing down on the knurled top of the implant placement tool disengaged the fixture mount.
Serial posts:
- Abstract : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Background : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- Background : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [3]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [4]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [5]
- Results : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Discussion : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- Discussion : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- Conclusions : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [3]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [4]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [5]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [6]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [7]
- Author information : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Additional information : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Rights and permissions : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Table 1 Comparison of % BIC in both groups : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Table 2 Descriptive statistics of the experimental and control group : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Fig. 1. Radiograph showing implants in the rabbit tibia : Osseointegration of standard and mini dental implant
- Fig. 2. Leica SP 1600 saw microtome : Osseointegration of standard and mini dental implant
- Fig. 3. Histological sections being obtained with Leica SP 1600 saw microtome : Osseointegration of standard and mini dental implant
- Fig. 4. Histological section of mini dental implant in rabbit tibia stained with methylene blue and basic fuchsin : Osseointegration of standard and mini dental implant
- Fig. 5. Histological section of standard implant in rabbit tibia stained with methylene blue and basic fuchsin : Osseointegration of standard and mini dental implant
- Fig. 6. Micro CT scan images of the MDIs and Ankylos® embedded in rabbit bone 6 weeks post implantation : Osseointegration of standard and mini dental implant