References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [4]
Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res. 1991;25(7):889–902.
Gotfredsen K, Wennerberg A, Johansson C, Skovgaard LT, Hjorting-Hansen E. Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits. J Biomed Mater Res. 1995;29(10):1223–31.
Technical Data Sheet, 3M. Literature review. St. Paul, MN: 3M ESPE Dental Products, 2009.
Steigenga J, Al-Shammari K, Misch C, Nociti Jr FH, Wang HL. Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits. J Periodontol. 2004;75(9):1233–41.
Faeda RS, Tavares HS, Sartori R, Guastaldi AC, Marcantonio Jr E. Biological performance of chemical hydroxyapatite coating associated with implant surface modification by laser beam: biomechanical study in rabbit tibias. J Oral Maxillofac Surg. 2009;67(8):1706–15.
He FM, Yang GL, Li YN, Wang XX, Zhao SF. Early bone response to sandblasted, dual acid-etched and H2O2/HCl treated titanium implants: an experimental study in the rabbit. Int J Oral Maxillofac Surg. 2009;38(6):677–81.
Rong M, Zhou L, Gou Z, Zhu A, Zhou D. The early osseointegration of the laser-treated and acid-etched dental implants surface: an experimental study in rabbits. J Mater Sci Mater Med. 2009;20(8):1721–8.
Marin C, Bonfante EA, Granato R, Suzuki M, Granjeiro JM, Coelho PG. The effect of alterations on resorbable blasting media processed implant surfaces on early bone healing: a study in rabbits. Implant Dent. 2011;20(2):167–77.
Yildiz A, Esen E, Kurkcu M, Damlar I, Daglioglu K, Akova T. Effect of zoledronic acid on osseointegration of titanium implants: an experimental study in an ovariectomized rabbit model. J Oral Maxillofac Surg. 2010;68(3):515–23.
Park YS, Yi KY, Lee IS, Han CH, Jung YC. The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae. Int J Oral Maxillofac Implants. 2005;20(1):31–8.
Serial posts:
- Abstract : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Background : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- Background : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [3]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [4]
- Methods : Osseointegration of standard and mini dental implants: a histomorphometric comparison [5]
- Results : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Discussion : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- Discussion : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- Conclusions : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [1]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [2]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [3]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [4]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [5]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [6]
- References : Osseointegration of standard and mini dental implants: a histomorphometric comparison [7]
- Author information : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Additional information : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Rights and permissions : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Table 1 Comparison of % BIC in both groups : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Table 2 Descriptive statistics of the experimental and control group : Osseointegration of standard and mini dental implants: a histomorphometric comparison
- Fig. 1. Radiograph showing implants in the rabbit tibia : Osseointegration of standard and mini dental implant
- Fig. 2. Leica SP 1600 saw microtome : Osseointegration of standard and mini dental implant
- Fig. 3. Histological sections being obtained with Leica SP 1600 saw microtome : Osseointegration of standard and mini dental implant
- Fig. 4. Histological section of mini dental implant in rabbit tibia stained with methylene blue and basic fuchsin : Osseointegration of standard and mini dental implant
- Fig. 5. Histological section of standard implant in rabbit tibia stained with methylene blue and basic fuchsin : Osseointegration of standard and mini dental implant
- Fig. 6. Micro CT scan images of the MDIs and Ankylos® embedded in rabbit bone 6 weeks post implantation : Osseointegration of standard and mini dental implant