References : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [2]
O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res. 2004;15(4):474–80.
Schwartz-Arad D, Herzberg R, Levin L. Evaluation of long-term implant success. J Periodontol. 2005;76(10):1623–8.
Alves CC, Neves M. Tapered implants: from indications to advantages. Int J Periodontics Restorative Dent. 2009;29(2):161–7.
Cawley P, Pavlakovic B, Alleyne DN, George R, Back T, Meredith N. The design of a vibration transducer to monitor the integrity of dental implants. Proc Inst Mech Eng H. 1998;212(4):265–72.
Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res. 1997;8(3):234–43.
Staedt H, Palarie V, Staedt A, Wolf JM, Lehmann KM, Ottl P, et al. Primary stability of cylindrical and conical dental implants in relation to insertion torque—a comparative ex vivo evaluation. Implant Dent. 2017;26(2):250–5.
Stocchero M, Toia M, Cecchinato D, Becktor JP, Coelho PG, Jimbo R. Biomechanical, biologic, and clinical outcomes of undersized implant surgical preparation: a systematic review. Int J Oral Maxillofac Implants. 2016;31(6):1247–63.
Misch CE. Contemporary implant dentistry. 3rd ed. St. Louis: Elsevier; 2008. p. 1102.
Lozano-Carrascal N, Salomo-Coll O, Gilabert-Cerda M, Farre-Pages N, Gargallo-Albiol J, Hernandez-Alfaro F. Effect of implant macro-design on primary stability: a prospective clinical study. Med Oral Patol Oral Cir Bucal. 2016;21(2):e214–21.
Sierra-Rebolledo A, Allais-Leon M, Maurette-O'Brien P, Gay-Escoda C. Primary apical stability of tapered implants through reduction of final drilling dimensions in different bone density models: a biomechanical study. Implant Dent. 2016;25(6):775–82.
Acil Y, Sievers J, Gulses A, Ayna M, Wiltfang J, Terheyden H. Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants. Odontology. 2016. [Epub ahead of print]
Oxby G, Oxby F, Oxby J, Saltvik T, Nilsson P. Early loading of fluoridated implants placed in fresh extraction sockets and healed bone: a 3- to 5-year clinical and radiographic follow-up study of 39 consecutive patients. Clin Implant Dent Relat Res. 2015;17(5):898–907.
Serial posts:
- Abstract : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [2]
- Background : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [1]
- Background : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [2]
- Methods : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [1]
- Methods : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [2]
- Results : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- Discussion : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [1]
- Discussion : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [2]
- Conclusions : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- Notes : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- References : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [1]
- References : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [2]
- References : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study [3]
- Author information : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- Rights and permissions : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- About this article : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- Table 1 Patient selection criteria : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- Table 2 Outcome success criteria : Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
- Fig. 1. Implant design. The OSPTX and OSP implants are manufactured from high-grade commercially pure titanium with surface roughness produced via a fluoride treatment process. The OSP implant is a screw-shaped self-tapping implant. The diameter used in this study was 4.0 mm. The implant length used in this study was 8 mm. The OSPTX implant has the same features as the OSP except the apex of the implant is tapered : Comparative evaluation of the stability of two different dental implant
- Fig. 2. ISQ values at placement, 6 weeks, 6 months, and 1 year. Mean and standard deviation of ISQ values taken at placement, 6 weeks, 6 months, and 1 year is presented. No statistical significant difference was determined between ISQ values at all time points. (p < 0.05) : Comparative evaluation of the stability of two different dental implant
- Fig. 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 months was 0.2981 and at 1 year 0.6613 : Comparative evaluation of the stability of two different dental implant