Table 2 Results of assessment of sensory neural function after inferior alveolar nerve (IAN) transposition : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
Table 2 Results of assessment of sensory neural function after inferior alveolar nerve (IAN) transposition : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
author: Fumihiro Nishimaki, Hiroshi Kurita, Shinya Tozawa, Yuji Teramoto, Rishiho Nishizawa, Shin-ichi Yamada | publisher: drg. Andreas Tjandra, Sp. Perio, FISID
No. | Sex | Age (years) | Range of IAN lateralization (width) | Implant site | Follow-up period (months) | Scores on the SW test | Grade of neurosensory disturbance (Highet grading) |
---|---|---|---|---|---|---|---|
1 | Female | 64 | 2 teeth | 34, 35, 36 | Lost | – | – |
2 | Female | 71 | 2 teeth | 43, 45, 46 | 105 | 1 | 2 |
3 | Female | 59 | 3 teeth | 35, 36, 37 | 53 | 7 | 3+ |
3 teeth | 45, 46, 47 | 9 | 4 | ||||
4 | Female | 68 | 3 teeth | 45, 47 | 49 | 8 | 3+ |
5 | Female | 38 | 3 teeth | 43, 44, 46 | 13 | 3 | 3+ |
6 | Male | 64 | 4 teeth | 43, 44, 46 | 12 | 9 | 4 |
7 | Female | 75 | 2 teeth | 44, 45 | 13 | 8 | 3+ |
Table 2 Results of assessment of sensory neural function after inferior alveolar nerve (IAN) transposition
Serial posts:
- Abstract : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Background : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Methods : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Results : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Discussion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [1]
- Discussion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [2]
- Discussion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [3]
- Conclusions : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- References : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [1]
- References : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement [2]
- Acknowledgements : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Author information : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Additional information : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Rights and permissions : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- About this article : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Table 1 Highet grading : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Table 2 Results of assessment of sensory neural function after inferior alveolar nerve (IAN) transposition : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant placement
- Fig. 1. Alveolar nerve repositioning in a partially edentulous mandible. a Preoperative radiograph. b The inferior alveolar nerve was transposed from the mental foramen. c Postoperative radiograph after implant insertion : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant
- Fig. 2. a SW perception tester is composed of different diameters (a: 0.165 mm, b: 0.215 mm, c: 0.315 mm). b The use of SW perception tester started from a filament of 0.165 mm in diameter of the most weak force, and performed three times at one site : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant
- Fig. 3. Site of evaluation. (1) Corner of the mouth: 5 mm below the corner of the mouth. (2) Lower lip: 5 mm laterally from the midline. (3) Mental region: at the midpoint of the perpendicular from the lower edge to the lower lip to the chin and 5 mm laterally from the midline : Subjective and qualitative assessment of neural disturbance after inferior alveolar nerve transposition for dental implant