Open hour: senin - sabtu 09:00:00 - 20:00:00; minggu & tanggal merah tutup

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7-mm-length dental implant at the time of its placement at the mandibular left second premolar in a 63-year-old Caucasian female. b Radiographic image of a three-unit fixed partial denture upon its initial placement. The dental implant is the anterior abutment with the prosthesis screw retained to it. The distal abutment is the mandibular left sec...

Fig. 1. a Initial radiograph exposed at abutment i...

Fig. 1. a Initial radiograph exposed at abutment installation on a 5-mm-wide by 7-mm-length dental implant used to help support a removable partial denture for a 71-year-old Caucasian male. b Radiograph of the area taken at 82 months demonstrates good bone stability. c Clinical image of the area 82 months later. Soft tissue remains healthy. The two teeth anterior are in the process of receivin...

Table 5 Resonance frequency analysis : A 1–7 ye...

Time ISQ n Implant insertion 73.6 ± 8.1 86 1–4 weeks ...

Table 4 Implant survival, life table analysis : A ...

Interval Implants Failed Not followed CSR (%) Insertion to 1 year ...

Table 3 Specification of failed implants (three im...

Sex Age Smoker Risk factors Position Implant diameter ...

Table 2 Implant and site-related specifications : ...

  Number Percent Jaw Maxilla 60 69.8 Mandible ...

Table 1 Patient demographics : A 1–7 year retro...

  Number Percent Age (years) 20–29 1 1.3 30–39 ...

About this article : A 1–7 year retrospective f...

Rosen, P.S., Sahlin, H., Seemann, R. et al. A 1–7 year retrospective follow-up on consecutively placed 7-mm-long dental implants with an electrowetted surface. Int J Implant Dent 4, 24 (2018). https://doi.org/10.1186/s40729-018-0136-4 Download citation Received: 08 January 2018 Accepted: 21 May 2018 Published: 23 August 2018 DOI: https://doi.org/10.1186/s40729-018-0136...

Rights and permissions : A 1–7 year retrospecti...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : A 1–7 year retrospective ...

The study was performed in compliance with the Declaration of Helsinki. Data collection was performed in such a manner that subjects could not be identified, and therefore, it was exempt from IRB review according to Federal Regulation 45 CFR 46.101(b). All participants consented to publish their information details through the clinic’s standard patient consent procedure. Also, all images appear...

Author information : A 1–7 year retrospective f...

Clinical Professor of Periodontics, Baltimore College of Dental Surgery, University of Maryland Dental School, Baltimore, MD, USA Paul S. Rosen Private Practice limited to Periodontics and Dental Implants, 907 Floral Vale Boulevard, Yardley, PA, 19067, USA Paul S. Rosen Neoss Ltd, Gothenburg, Sweden Herman Sahlin University Clinic of Craniofacial, Maxillofacial and Oral Surgery, Vienna, Aust...

Availability of data and materials : A 1–7 year...

Due to the ethical and legal responsibility to respect participants’ rights to privacy and to protect their identity, the clinical dataset is not made publicly available.

References : A 1–7 year retrospective follow-up...

Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Survival rates of short (6 mm) micro-rough surface implants: a review of literature and meta-analysis. Clin Oral Implants Res. 2014;25(5):539–45. Chrcanovic BR, Albrektsson T, Wennerberg A. Diabetes and oral implant failure: a systematic review. J Dent Res. 2014;93(9):859–67. Giro G, Chambrone L, Goldstein A, Rodrigues JA,...

References : A 1–7 year retrospective follow-up...

Jemt T, Olsson M, Franke SV. Incidence of first implant failure: a retroprospective study of 27 years of implant operations at one specialist clinic. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e501–10. Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G. Impact of dental implant length on early failure rates: a meta-analysis of observational studies. J Clin Periodontol. 2011;38(9):856...

Abbreviations : A 1–7 year retrospective follow...

Cumulative survival rate Implant stability quotient Insertion torque Odds ratio Resonance frequency analysis Relative risk

Conclusion : A 1–7 year retrospective follow-up...

The current retrospective consecutive case series study provides preliminary data that treatment with 7-mm-length short implants with a hydrophilic electrowetted surface is a reasonable approach in sites with limited vertical bone dimension. It adds to the body of evidence supporting short implant use for compromised sites. The success seen might be attributed to the larger implant diameters that ...

Discussion : A 1–7 year retrospective follow-up...

Thirty-six percent of the implants in the study were placed in extraction sockets. Provided that sufficient initial implant stability is achieved, there should be no additional risk factors compared to implants in healed sites. Studies have shown no difference in marginal bone remodeling between immediately placed and delayed implants [15]. The biggest limitation of the current study is its very ...

Discussion : A 1–7 year retrospective follow-up...

A wide distribution in implant insertion torque (10–50 Ncm) was seen in the study. This reflects the variety of clinical situations in which the implants were placed. Assessments were made by using both the RFA value and the insertion torque as to first whether an implant should have been left to heal in the first place and if so, how this would be best accomplished, i.e., through its submergen...

Discussion : A 1–7 year retrospective follow-up...

This retrospective study is the first to look at short dental implants with a hydrophilic electrowetted surface. The survival data suggest that this treatment is a viable option to care. In a systematic review that identified 13 studies on implants shorter than 10 mm, the CSR from the individual studies ranged from 80 to 100% with a combined CSR of 98.3% after 5 years, 94.8% after 6 years, and ...

Results : A 1–7 year retrospective follow-up on...

The chart review identified 86 placed implants in 75 patients. Table 1 summarizes the patient demographics of the 75 patients. Patients ranged in age from 29 to 88 years with a mean of 61.0 ± 12.5 years. Twenty-seven of the patients were males and 48 were females. Table 2 summarizes the implant and site-related information of the 86 placed implants. Mean insertion torque was 30.1 ± 7...

Methods : A 1–7 year retrospective follow-up on...

Baseline parameters, both patient- and implant-related, as well as follow-up parameters (implant survival, follow-up time, and resonance frequency analysis) were collected from a review of the patient records. The main study parameters (principal outcome parameters) were defined to be implant loss and follow-up time. The cumulative survival rate was estimated. The influence of several factors on ...

Methods : A 1–7 year retrospective follow-up on...

A retrospective study on short 7 mm hydrophilic implants from a single center was conducted in a private practice limited to periodontics and surgical dental implant placements from one of the authors, PSR (Yardley, Pennsylvania, USA). An exhaustive chart review identified 75 patients for analysis that were treated with 86 short (7 mm) implants during a 5-year period (September 1, 2009, to Novem...

Background : A 1–7 year retrospective follow-up...

The aim of this retrospective consecutive case series study was to investigate implant survival rate and analyze possible factors affecting the survival of short implants placed in one surgical practice focused on implantology and periodontology in a temporal cohort.

Background : A 1–7 year retrospective follow-up...

In the past decades, the osseointegration rate of dental implants has dramatically increased, particularly in sites of softer dental bone, which may be attributed to the introduction of moderately roughened surfaces [1, 2]. Moreover, because of this increase in success, clinicians have attempted to push the envelope and place implants into sites that may provide a greater challenge as they wish to...

Abstract : A 1–7 year retrospective follow-up o...

This retrospective consecutive case series study was performed to determinate the survival rate and implant stability of short (7 mm length) dental implants with an electrowetted hydrophilic surface that were in function from 1 to 7 years. A retrospective chart review identified and evaluated 86 consecutively placed 7-mm-long dental implants (ProActive, Neoss Ltd., Harrogate, England) in 75 pat...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7-mm-length dental implant at the time of its placement at the mandibular left second premolar in a 63-year-old Caucasian female. b Radiographic image of a three-unit fixed partial denture upon its initial placement. The dental implant is the anterior abutment with the prosthesis screw retained to it. The distal abutment is the mandibular left sec...

Fig. 1. a Initial radiograph exposed at abutment i...

Fig. 1. a Initial radiograph exposed at abutment installation on a 5-mm-wide by 7-mm-length dental implant used to help support a removable partial denture for a 71-year-old Caucasian male. b Radiograph of the area taken at 82 months demonstrates good bone stability. c Clinical image of the area 82 months later. Soft tissue remains healthy. The two teeth anterior are in the process of receivin...

Table 5 Resonance frequency analysis : A 1–7 ye...

Time ISQ n Implant insertion 73.6 ± 8.1 86 1–4 weeks ...

Table 4 Implant survival, life table analysis : A ...

Interval Implants Failed Not followed CSR (%) Insertion to 1 year ...

Table 3 Specification of failed implants (three im...

Sex Age Smoker Risk factors Position Implant diameter ...

Table 2 Implant and site-related specifications : ...

  Number Percent Jaw Maxilla 60 69.8 Mandible ...

Table 1 Patient demographics : A 1–7 year retro...

  Number Percent Age (years) 20–29 1 1.3 30–39 ...

About this article : A 1–7 year retrospective f...

Rosen, P.S., Sahlin, H., Seemann, R. et al. A 1–7 year retrospective follow-up on consecutively placed 7-mm-long dental implants with an electrowetted surface. Int J Implant Dent 4, 24 (2018). https://doi.org/10.1186/s40729-018-0136-4 Download citation Received: 08 January 2018 Accepted: 21 May 2018 Published: 23 August 2018 DOI: https://doi.org/10.1186/s40729-018-0136...

Rights and permissions : A 1–7 year retrospecti...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : A 1–7 year retrospective ...

The study was performed in compliance with the Declaration of Helsinki. Data collection was performed in such a manner that subjects could not be identified, and therefore, it was exempt from IRB review according to Federal Regulation 45 CFR 46.101(b). All participants consented to publish their information details through the clinic’s standard patient consent procedure. Also, all images appear...

Author information : A 1–7 year retrospective f...

Clinical Professor of Periodontics, Baltimore College of Dental Surgery, University of Maryland Dental School, Baltimore, MD, USA Paul S. Rosen Private Practice limited to Periodontics and Dental Implants, 907 Floral Vale Boulevard, Yardley, PA, 19067, USA Paul S. Rosen Neoss Ltd, Gothenburg, Sweden Herman Sahlin University Clinic of Craniofacial, Maxillofacial and Oral Surgery, Vienna, Aust...

Availability of data and materials : A 1–7 year...

Due to the ethical and legal responsibility to respect participants’ rights to privacy and to protect their identity, the clinical dataset is not made publicly available.

References : A 1–7 year retrospective follow-up...

Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Survival rates of short (6 mm) micro-rough surface implants: a review of literature and meta-analysis. Clin Oral Implants Res. 2014;25(5):539–45. Chrcanovic BR, Albrektsson T, Wennerberg A. Diabetes and oral implant failure: a systematic review. J Dent Res. 2014;93(9):859–67. Giro G, Chambrone L, Goldstein A, Rodrigues JA,...

References : A 1–7 year retrospective follow-up...

Jemt T, Olsson M, Franke SV. Incidence of first implant failure: a retroprospective study of 27 years of implant operations at one specialist clinic. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e501–10. Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G. Impact of dental implant length on early failure rates: a meta-analysis of observational studies. J Clin Periodontol. 2011;38(9):856...

Abbreviations : A 1–7 year retrospective follow...

Cumulative survival rate Implant stability quotient Insertion torque Odds ratio Resonance frequency analysis Relative risk

Conclusion : A 1–7 year retrospective follow-up...

The current retrospective consecutive case series study provides preliminary data that treatment with 7-mm-length short implants with a hydrophilic electrowetted surface is a reasonable approach in sites with limited vertical bone dimension. It adds to the body of evidence supporting short implant use for compromised sites. The success seen might be attributed to the larger implant diameters that ...

Discussion : A 1–7 year retrospective follow-up...

Thirty-six percent of the implants in the study were placed in extraction sockets. Provided that sufficient initial implant stability is achieved, there should be no additional risk factors compared to implants in healed sites. Studies have shown no difference in marginal bone remodeling between immediately placed and delayed implants [15]. The biggest limitation of the current study is its very ...

Discussion : A 1–7 year retrospective follow-up...

A wide distribution in implant insertion torque (10–50 Ncm) was seen in the study. This reflects the variety of clinical situations in which the implants were placed. Assessments were made by using both the RFA value and the insertion torque as to first whether an implant should have been left to heal in the first place and if so, how this would be best accomplished, i.e., through its submergen...

Discussion : A 1–7 year retrospective follow-up...

This retrospective study is the first to look at short dental implants with a hydrophilic electrowetted surface. The survival data suggest that this treatment is a viable option to care. In a systematic review that identified 13 studies on implants shorter than 10 mm, the CSR from the individual studies ranged from 80 to 100% with a combined CSR of 98.3% after 5 years, 94.8% after 6 years, and ...

Results : A 1–7 year retrospective follow-up on...

The chart review identified 86 placed implants in 75 patients. Table 1 summarizes the patient demographics of the 75 patients. Patients ranged in age from 29 to 88 years with a mean of 61.0 ± 12.5 years. Twenty-seven of the patients were males and 48 were females. Table 2 summarizes the implant and site-related information of the 86 placed implants. Mean insertion torque was 30.1 ± 7...

Methods : A 1–7 year retrospective follow-up on...

Baseline parameters, both patient- and implant-related, as well as follow-up parameters (implant survival, follow-up time, and resonance frequency analysis) were collected from a review of the patient records. The main study parameters (principal outcome parameters) were defined to be implant loss and follow-up time. The cumulative survival rate was estimated. The influence of several factors on ...

Methods : A 1–7 year retrospective follow-up on...

A retrospective study on short 7 mm hydrophilic implants from a single center was conducted in a private practice limited to periodontics and surgical dental implant placements from one of the authors, PSR (Yardley, Pennsylvania, USA). An exhaustive chart review identified 75 patients for analysis that were treated with 86 short (7 mm) implants during a 5-year period (September 1, 2009, to Novem...

Background : A 1–7 year retrospective follow-up...

The aim of this retrospective consecutive case series study was to investigate implant survival rate and analyze possible factors affecting the survival of short implants placed in one surgical practice focused on implantology and periodontology in a temporal cohort.

Background : A 1–7 year retrospective follow-up...

In the past decades, the osseointegration rate of dental implants has dramatically increased, particularly in sites of softer dental bone, which may be attributed to the introduction of moderately roughened surfaces [1, 2]. Moreover, because of this increase in success, clinicians have attempted to push the envelope and place implants into sites that may provide a greater challenge as they wish to...

Abstract : A 1–7 year retrospective follow-up o...

This retrospective consecutive case series study was performed to determinate the survival rate and implant stability of short (7 mm length) dental implants with an electrowetted hydrophilic surface that were in function from 1 to 7 years. A retrospective chart review identified and evaluated 86 consecutively placed 7-mm-long dental implants (ProActive, Neoss Ltd., Harrogate, England) in 75 pat...