References : Customized SmartPeg for measurement of resonance frequency of mini dental implants [2]

References : Customized SmartPeg for measurement of resonance frequency of mini dental implants [2]

author: Jagjit Singh Dhaliwal, Rubens F Albuquerque Jr, Ali Fakhry, Sukhbir Kaur, Jocelyne S Feine | publisher: drg. Andreas Tjandra, Sp. Perio, FISID

Shatkin TE, Oppenheimer BD, Oppenheimer AJ. Mini dental implants for long-term fixed and removable prosthetics: a retrospective analysis of 2514 implants placed over a five-year period. Compend Contin Educ Dent. 2007;28(2):92–9. quiz 100-1. Epub 2007/02/27.

Griffitts TM, Collins CP, Collins PC. Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2005;100(5):e81–4. Epub 2005/10/26.

Albrektsson T, Sennerby L. State of the art in oral implants. J Clin Periodontol. 1991;18(6):474–81. Epub 1991/07/01.

Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007;22(5):743–54. Epub 2007/11/03.

Davies JE. Mechanisms of endosseous integration. Int J Prosthodont. 1998;11(5):391–401. Epub 1999/01/29.

Romanos GE. Bone quality and the immediate loading of implants-critical aspects based on literature, research, and clinical experience. Implant Dent. 2009;18(3):203–9. Epub 2009/06/11.

Cawley P, Pavlakovic B, Alleyne DN, George R, Back T, Meredith N. The design of a vibration transducer to monitor the integrity of dental implants. Proc Inst Mech Eng H J Eng Med. 1998;212(4):265–72. Epub 1998/10/14.

Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res. 1998;43(2):192–203. Epub 1998/06/10.

Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop. 2006;67(3):162–74. Epub 2006/06/01.

Boice GW, Kraut RA. Maxillary denture retention using rare earth magnets and endosteal implants. Int J Oral Implantol. 1991;7(2):23–7. Epub 1991/01/01.

Sullivan DY, Sherwood RL, Collins TA, Krogh PH. The reverse-torque test: a clinical report. Int J Oral Maxillofac Implants. 1996;11(2):179–85. Epub 1996/03/01.

Branemark R, Ohrnell LO, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. Biomaterials. 1997;18(14):969–78. Epub 1997/07/01.

Branemark R, Ohrnell LO, Skalak R, Carlsson L, Branemark PI. Biomechanical characterization of osseointegration: an experimental in vivo investigation in the beagle dog. J Orthop Res. 1998;16(1):61–9. Epub 1998/05/09.