A meta-analysis on the effect of implant characteristics
A meta-analysis on the effect of implant characteristics on the survival of the wide-diameter implant
Abstract
The purposes of the study are to study the implant survival of the wide-diameter implant and to analyze if the length, the implant surface, or the placement location has any effect on its survival. Electronic databases were searched from inception to Dec 2014. Studies included in the review had implants placed in areas of adequate bone width and had clear inclusion and exclusion criteria for patient selection. Immediately placed and immediately loaded implants were excluded. A meta-analysis was done using the “random effects” model on the included studies. And, a meta-regression was used to evaluate the effects of location, length, and surface on the implant survival. Of the six studies selected, three evaluated surface-treated implants and three machined implants. The overall pooled survival rate of the wide implant is 96.3 %. The meta-regression showed that when using a wide implant, neither its surface nor its length nor its position in the maxilla or mandible adversely affected its survival (P > 0.05). This meta-analysis concluded that the location, length, and surface of the wide-diameter implant did not affect its survival and therefore suggested that when the conditions of the implant site corresponded to the inclusion criteria of our meta-analysis, choosing a wide-diameter implant in the posterior mandible or maxilla, where implant length may be limited by the nerve or the sinus, the use of a short implant regardless of its surface would not affect its survival.
Serial posts:
- A meta-analysis on the effect of implant characteristics
- Review : A meta-analysis on the effect of implant characteristics
- Materials and methods : A meta-analysis on the effect of implant characteristics (1)
- Materials and methods : A meta-analysis on the effect of implant characteristics (2)
- Results : A meta-analysis on the effect of implant characteristics
- Discussion : A meta-analysis on the effect of implant characteristics (1)
- Discussion : A meta-analysis on the effect of implant characteristics (2)
- Conclusion : A meta-analysis on the effect of implant characteristics
- Figure 1. Study selection for wide-diameter implant articles
- Figure 2. Forest plot
- Figure 3. Funnel plot
- Table 1 Wide-diameter implants
- Table 2 Wide surface-treated Implants
- Table 3 Wide machined implants
- Table 4 Implants used in the maxilla and mandible
- Table 5 Meta-analysis implant data—pooled analysis
- Table 6 Heterogeneity statistics
- Table 7 Meta-regression—effect of surface and lengths