Table 1 Participating patients and the number and site of the inserted implants : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
Table 1 Participating patients and the number and site of the inserted implants : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
author: Jonas Lorenz, Henriette Lerner, Robert A Sader, Shahram Ghanaati | publisher: drg. Andreas Tjandra, Sp. Perio, FISID
Patient | Gender (m/f) | Age (years) | Implant localization (region) | Implant diameter (mm) | Implant length (mm) | Augmentation material | Prosthetic rehabilitation |
---|---|---|---|---|---|---|---|
1 | f | 50 | 32 | 3.5 | 13 | HA + β-TCP | r.p |
34 | 4.3 | 11 | HA + β-TCP | r.p | |||
42 | 3.5 | 13 | HA + β-TCP | r.p | |||
44 | 4.3 | 11 | HA + β-TCP | r.p | |||
2 | m | 61 | 36 | 3.5 | 11 | HA + β-TCP | f.p. |
37 | 3.5 | 11 | HA + β-TCP | f.p. | |||
46 | 3.5 | 11 | HA + β-TCP | f.p. | |||
47 | 3.5 | 11 | HA + β-TCP | f.p. | |||
3 | m | 48 | 26 | 4.3 | 11 | HA + β-TCP | f.p. |
4 | f | 54 | 21 | 4.3 | 11 | HA + β-TCP | f.p. |
5 | f | 45 | 23 | 3.5 | 13 | HA | f.p. |
26 | 4.3 | 11 | HA | f.p. | |||
27 | 4.3 | 11 | HA | f.p. | |||
6 | m | 56 | 32 | 3.5 | 13 | HA + β-TCP | f.p. |
42 | 3.5 | 13 | HA + β-TCP | f.p. | |||
7 | m | 54 | 36 | 4.3 | 11 | HA + β-TCP | f.p. |
46 | 3.5 | 11 | HA + β-TCP | f.p. | |||
36 | 4.3 | 11 | HA + β-TCP | f.p. | |||
8 | f | 73 | 16 | 3.5 | 11 | HA + β-TCP | f.p. |
26 | 3.5 | 11 | HA + β-TCP | f.p. | |||
9 | m | 64 | 27 | 4.3 | 11 | HA + β-TCP | f.p. |
10 | f | 62 | 15 | 3.5 | 11 | HA + β-TCP | f.p. |
16 | 3.5 | 11 | HA + β-TCP | f.p. | |||
17 | 3.5 | 11 | HA + β-TCP | f.p. | |||
24 | 3.5 | 11 | HA + β-TCP | f.p. | |||
36 | 4.3 | 11 | HA + β-TCP | f.p. | |||
46 | 3.5 | 11 | HA + β-TCP | f.p. | |||
11 | f | 75 | 35 | 3.5 | 11 | HA + β-TCP | f.p. |
36 | 3.5 | 11 | HA + β-TCP | f.p. | |||
12 | f | 52 | 16 | 4.3 | 11 | HA + β-TCP | f.p. |
13 | m | 46 | 24 | 3.5 | 11 | HA + β-TCP | f.p. |
25 | 3.5 | 11 | HA + β-TCP | f.p. | |||
26 | 3.5 | 11 | HA + β-TCP | f.p. | |||
46 | 4.3 | 11 | HA + β-TCP | f.p. | |||
14 | f | 66 | 36 | 3.5 | 11 | HA + β-TCP | f.p. |
37 | 3.5 | 11 | HA + β-TCP | f.p. | |||
15 | f | 63 | 11 | 3.5 | 13 | HA | f.p. |
16 | f | 53 | 36 | 3.5 | 11 | HA + β-TCP | f.p. |
46 | 3.5 | 11 | HA + β-TCP | f.p. | |||
47 | 3.5 | 11 | HA + β-TCP | f.p. | |||
17 | f | 51 | 14 | 3.5 | 13 | HA + β-TCP | f.p. |
15 | 3.5 | 13 | HA + β-TCP | f.p. | |||
18 | m | 60 | 27 | 4.3 | 11 | HA + β-TCP | f.p. |
47 | 4.3 | 11 | HA + β-TCP | f.p. | |||
19 | m | 75 | 22 | 3.5 | 13 | HA + β-TCP | f.p. |
24 | 3.5 | 13 | HA + β-TCP | f.p. | |||
20 | m | 62 | 26 | 4.3 | 11 | HA + β-TCP | f.p. |
Total 20 | Total 11*f; 9*m | Mean 58.5 | Total 47; 23*u.j, 24*l.j. | Total 32*3.5 mm, 15*4.3 mm | Total 37*11 mm, 10*13 mm | Total 43*HA + β-TCP, 4*HA |
Total 43*f.p., 4*r.p |
Table 1 Participating patients and the number and site of the inserted implants
Serial posts:
- Abstract : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Background : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [1]
- Background : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [2]
- Background : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [3]
- Methods : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [1]
- Methods : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [2]
- Methods : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [3]
- Results : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [1]
- Results : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [2]
- Discussion : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [1]
- Discussion : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [2]
- Discussion : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [3]
- Conclusions : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Abbreviations : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- References : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [1]
- References : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system [2]
- Author information : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Ethics declarations : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Rights and permissions : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- About this article : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Table 1 Participating patients and the number and site of the inserted implants : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Table 2 Results from the clinical and radiological 3-year follow-up investigation : Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
- Fig. 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer) : Investigation of peri-implant
- Fig. 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP : Investigation of peri-implant