Fig. 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP
Fig. 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP
Fig. 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer)
Fig. 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer)
Patient
Implant-localization (region)
Implant loss (+/−)
Buccal width of keratinized peri-implant gingiva (mm)
Buccal thickness of keratinized peri-implant gi...
Patient
Gender (m/f)
Age (years)
Implant localization (region)
Implant diameter (mm)
...
Lorenz, J., Lerner, H., Sader, R.A. et al. Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system.
Int J Implant Dent 3, 41 (2017). https://doi.org/10.1186/s40729-017-0104-4
Download citation
Received...
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...
This study was conducted in compliance with the principles of the Declaration of Helsinki, and the approval of the ethics committee required for the study was obtained from the Ethics Committee of the Medical Center of the Goethe University Frankfurt. The procedures to be performed were explained in detail, and the patients signed the consent form.
Jonas Lorenz, Henriette Lerner, Robert Sader, an...
Department for Oral, FORM-Lab, Cranio-Maxillofacial, and Facial Plastic Surgery, Medical Center of the Goethe University Frankfurt, Frankfurt am Main, Germany
Jonas Lorenz, Robert A. Sader & Shahram Ghanaati
HL-Dentclinic, Baden-Baden, Germany
Henriette Lerner
You can also search for this author in
PubMed Google Scholar
You can also search for this author in
...
Lerner H, Lorenz J, Sader R, Ghanaati S. Two-year retrospective study of periimplant health and periimplant bone stability after immediate implant placement of a newly developed bone level implant system—a first report. EDI Journal (European Association of Dental Implantologists, Teamwork Media); 2017; ahead of print.
Ghanaati S, Lorenz J, Obreja K, Choukroun J, Landes C, Sader R. Nanocrystalli...
Gurgel BC, Montenegro SC, Dantas PM, Pascoal AL, Lima KC, Calderon PD. Frequency of peri-implant diseases and associated factors. Clin Oral Implants Res. 2016; doi: 10.1111/clr.12944
Qian J, Wennerberg A, Albrektsson T. Reasons for marginal bone loss around oral implants. Clin Implant Dent Relat Res. 2012;14(6):792–807.
Berglundh T, Lindhe J, Ericsson I, Marinello C, Liljenberg B, Thomsen P....
β-tricalcium phosphate
Bleeding on probing
Fixed prosthetics
Guided bone regeneration
Hydroxyapatite
Multinucleated giant cells
Pink Esthetic Score
Removable prosthetics
In the present study, the implant and peri-implant hard- and soft-tissue stability was analyzed in a bone level implant system placed simultaneously with a GBR procedure 3 years after prosthetic loading. Peri-implant hard- and soft-tissue parameters such as width and thickness of peri-implant keratinized gingiva, probing depth, BOP, PES, peri-implant bone loss, and the presence of peri-implant os...
Comparing the present results to the aforementioned study with the same implant system on immediately placed implants, it seems that the GBR augmentation procedure has no influence on the long-term stability of the implants. In both studies with different placement modalities and protocols, comparable clinical and radiological results were achieved. This leads to the assumption that the investigat...
The tissue reaction, however, did not only differ in bone substitute materials of different origin but also in bone substitute materials of the same origin. In an in vivo trial, two xenogeneic bone substitute materials processed with different techniques were implanted subcutaneously in CD-1 mice for up to 60 days. Both bone substitute materials showed good integration within the peri-implant tis...
In the present retrospective study, C-Tech bone level implants placed simultaneously with a GBR procedure around the implant shoulder were investigated clinically and radiologically after at least 3 years of loading to assess peri-implant tissue conditions and document peri-implant tissue stability.
A total of 47 implants were placed in the upper (23 implants) and lower jaw (24 implants) of 20 p...
Investigation of the esthetic appearance via PES revealed a mean point score of 10.1 (ranging from 7 to 13) from a maximum of 14. The highest values and therefore acceptance were found in the alveolar process deficiency and the soft-tissue level, which can be interpreted as a benefit of the augmentation procedure around the implant shoulder.
Peri-implant bone loss calculated using the average bon...
Altogether, 47 implants were placed in the upper and lower jaws of a total of 20 patients. In all implants, lateral augmentation in a GBR process was performed simultaneously with implant placement due to reduced horizontal or vertical height of the alveolar crest. A total of 23 implants were placed in the upper jaw and 24 implants in the lower jaw. The implant diameter varied between 3.5 mm (32 ...
Investigation parameters:
Implant being in situ
Width and thickness of peri-implant keratinized gingiva
Pink Esthetic Score (PES)
Probing depth
BOP
Peri-implant bone loss
Presence of peri-implant osteolysis
In the present retrospective study, bone level implants (C-Tech Esthetic Line implants) were investigated clinically and radiologically. The bone level implant system has a Morse-locking conical implant-abutment connection with platform switching and an indexing hex that allows subcrestal implant placement and aims to prevent peri-implant bone loss. The surface of the implant system is manufacture...
In the present retrospective study, 47 dental implants (C-Tech Esthetic Line implants) from 20 patients (11 female, 9 male) with a mean age of 58.5 years (45–75 years) were analyzed clinically and radiologically. Implant placement and follow-up investigation was performed at the HL Dentclinic in Baden-Baden, Germany. The study was approved by the ethics commission of the medical department of ...
The aim of the present retrospective investigation was to assess clinically and radiologically peri-implant tissue conditions and document peri-implant tissue stability in C-Tech implants when placed simultaneously with a GBR augmentation procedure after at least 3 years of loading.
The ability of bone substitute materials to form a sufficient and stable implantation bed has been proven in numerous clinical trials; however, it is still to a certain degree unclear if the different tissue reactions have an impact on the establishment of a peri-implant infection, especially when these biomaterials are used for augmentations around the implant shoulder. Due to the two-stage desig...
The prevalence of peri-implantitis has grown in the past few years and has become a major issue in implant dentistry. Long-term stable and healthy soft- and hard-tissue conditions should be achieved in combination with esthetically and functionally satisfying results. However, the rising number of placed implants in the past decades has come with an increase in the prevalence of peri-implantitis [...
Guided bone regeneration (GBR) has been proven to be a reliable therapy to regenerate missing bone in cases of atrophy of the alveolar crest. The aim of the present retrospective analysis was to assess peri-implant tissue conditions and document peri-implant tissue stability in C-Tech implants when placed simultaneously with a GBR augmentation procedure.
A total of 47 implants, which were placed ...
Figure 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP
Figure 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer)
Patient
Implant-localization (region)
Implant loss (+/−)
Buccal width of keratinized peri-implant gingiva (mm)
Buccal thickness of keratinized peri-implant gingiva (mm)
Pink Esthetic Score (PES)
Probing depth (mm) at four sites (mb, db, mo, do)
Bleeding on Probing (+/−) at four sites (mb, db, mo, do)
Peri-implant bone loss (mm)
Presence of peri-implant osteolysis (+/−)
...
Patient
Gender (m/f)
Age (years)
Implant localization (region)
Implant diameter (mm)
Implant length (mm)
Augmentation material
Prosthetic rehabilitation
1
f
50
32
3.5
13
HA + β-TCP
r.p
34
4.3
11
HA + β-TCP
r.p
42
3.5
13
HA + β-TCP
r.p
44
4.3
11
HA + β-TCP
r.p
2
m
61
36
3.5
11
HA + β-TCP
...
Abbreviations
β-TCP:
β-tricalcium phosphate
BOP:
Bleeding on probing
F.P.:
Fixed prosthetics
GBR:
Guided bone regeneration
HA:
Hydroxyapatite
MNGCs:
Multinucleated giant cells
PES:
Pink Esthetic Score
R.P.:
Removable prosthetics
References
Gurgel BC, Montenegro SC, Dantas PM, Pascoal AL, Lima KC, Calderon PD. Frequency o...
Comparing the present results to the aforementioned study with the same implant system on immediately placed implants, it seems that the GBR augmentation procedure has no influence on the long-term stability of the implants. In both studies with different placement modalities and protocols, comparable clinical and radiological results were achieved. This leads to the assumption that the inve...
The tissue reaction, however, did not only differ in bone substitute materials of different origin but also in bone substitute materials of the same origin. In an in vivo trial, two xenogeneic bone substitute materials processed with different techniques were implanted subcutaneously in CD-1 mice for up to 60 days. Both bone substitute materials showed good integration within the peri-impla...
Discussion
In the present retrospective study, C-Tech bone level implants placed simultaneously with a GBR procedure around the implant shoulder were investigated clinically and radiologically after at least 3 years of loading to assess peri-implant tissue conditions and document peri-implant tissue stability.
A total of 47 implants were placed in the upper (23 implants) and lower jaw (24...
Results
Altogether, 47 implants were placed in the upper and lower jaws of a total of 20 patients. In all implants, lateral augmentation in a GBR process was performed simultaneously with implant placement due to reduced horizontal or vertical height of the alveolar crest. A total of 23 implants were placed in the upper jaw and 24 implants in the lower jaw. The implant diameter varied between 3...
C-Tech implant system
In the present retrospective study, bone level implants (C-Tech Esthetic Line implants) were investigated clinically and radiologically. The bone level implant system has a Morse-locking conical implant-abutment connection with platform switching and an indexing hex that allows subcrestal implant placement and aims to prevent peri-implant bone loss. The surface of the implan...
Methods
Patient population
In the present retrospective study, 47 dental implants (C-Tech Esthetic Line implants) from 20 patients (11 female, 9 male) with a mean age of 58.5 years (45–75 years) were analyzed clinically and radiologically. Implant placement and follow-up investigation was performed at the HL Dentclinic in Baden-Baden, Germany. The study was approved by the ethics commissio...
Regarding the stability of peri-implant hard and soft tissue, biological or anatomical factors are not the only elements that could be proven to have an impact. Technical factors such as the implant-abutment connection are also known to be key factors for long-term stable hard- and soft-tissue health [11]. Regarding the implant-abutment connection, which seems to be the key issue, located on the i...
However, in most patients, the local bone amount is reduced due to atrophy, inflammatory processes, or resectional defects. Therefore, in the past few years, different techniques have been described to enlarge the local bone amount in prospective implant sites [7]. Besides methods such as GBR or the sinus augmentation technique, different augmentation materials have been investigated and establish...
Background
The prevalence of peri-implantitis has grown in the past few years and has become a major issue in implant dentistry. Long-term stable and healthy soft- and hard-tissue conditions should be achieved in combination with esthetically and functionally satisfying results. However, the rising number of placed implants in the past decades has come with an increase in the prevalence of ...
Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system
Abstract
Background
Guided bone regeneration (GBR) has been proven to be a reliable therapy to regenerate missing bone in cases of atrophy of the alveolar crest. T...
Figure 21. A dental class I occlusion was established only on the right side (lateral aspect)
Figure 20. The left side could not be restored to an ideal class I relationship from the original class II due to the pontic prosthesis
Figure 19. A full-mouth frontal aspect
Figure 18. OPT after prosthodontic finalization
Figure 17. Implants were used for implant-retained prostheses (abutment-cemented crowns), and a three-unit fixed partial denture pontic (crowns 25–27) was placed
Figure 16. After orthodontic treatment was completed, the prosthodontic phase took place
Figure 15. All implants received immediate healing screws
Figure 14. Implants placement after site preparation
Figure 13. Implant site preparation: OP5, IM2, OT4, and IM3 (correctly in sequence)
Figure 12. The total width flap was sutured
Figure 11. A mesiobuccal root surface exposure of element 16 required bone regeneration through Bio Oss and bone chip application
Figure 10. A triangular-shaped corticotomy was performed with inserts OT7 0.55 mm and OT7 special 0.35 mm to accelerate orthodontic tooth movements
Figure 9. A microsurgical corticotomy was mandatory to assist orthodontic tipping and intrusion of elements 16 and 17
Figure 8. Orthodontic bracket placement: left side view
Figure 7. Ortodontic bracket placement: right side view
Figure 6. Orthodontic bracket placement: frontal view
Figure 5. The panoramic radiography and cephalometric analysis revealed a partially edentulous mandible
Figure 4. The panoramic radiography and cephalometric analysis revealed a partially edentulous mandible
Figure 3. Some metal ceramic crowns in the upper left maxillary arch with a very poor esthetic appearance
Figure 2. Initial lateral intraoral aspect
Figure 1. Initial frontal intraoral aspect
A number of reports have indicated that orthodontic treatment can improve the periodontal situation in patients with pathologic migration by providing good function and improved esthetics after realignment.
It is generally recommended that orthodontic treatment should be preceded by periodontal therapy. In fact, orthodontic treatment when there is an inflammation/periodontal...
Discussion
The management of an anterior deep bite requires adequate treatment planning, especially if the clinical condition is associated with posterior DVO (vertical occlusion dimension) reduction due to multiple missing teeth. A multidisciplinary planning approach, including orthodontics, oral and periodontic surgery, and restorative dentistry, has an important role in t...
This was a preliminary stage before the first surgical corticotomy (performed with a piezo device).
A microsurgical corticotomy was mandatory to assist orthodontic tipping and intrusion of elements 16 and 17. This surgical procedure was performed by a piezo approach (Fig. 9).
A total width flap was elevated to make the cortical subapical and longitudinal bone cut possible. The ...
Case presentation
Diagnosis and etiology
A young female patient was referred to our dental clinic to resolve a malocclusion disorder due to missing teeth. She was unsatisfied with the functional aspect of her dentition. She had a second upper right molar very damaged by caries (17) (Figs. 1 and 2); it was also extruded due to missing antagonist teeth (I and II l...
A piezo surgery with corticotomies and implant placement as part of a multidisciplinary approach to treat malocclusion disorder in an adult patient: clinical report
Abstract
This clinical report illustrates a multidisciplinary approach for the rehabilitation of a young adult patient affected by a bilateral edentulous space and an anterior deep bite. The patient required orthodontics and surgic...