Open hour: senin - sabtu 09:00:00 - 20:00:00; minggu & tanggal merah tutup

Fig. 2. Clinical image of patient 4: a region 21 b...

Fig. 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP Fig. 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP

Fig. 1. Schematic representation of the technical ...

Fig. 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer) Fig. 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer)

Table 2 Results from the clinical and radiological...

Patient Implant-localization (region) Implant loss (+/−) Buccal width of keratinized peri-implant gingiva (mm) Buccal thickness of keratinized peri-implant gi...

Table 1 Participating patients and the number and ...

Patient Gender (m/f) Age (years) Implant localization (region) Implant diameter (mm) ...

About this article : Investigation of peri-implant...

Lorenz, J., Lerner, H., Sader, R.A. et al. Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system. Int J Implant Dent 3, 41 (2017). https://doi.org/10.1186/s40729-017-0104-4 Download citation Received...

Rights and permissions : Investigation of peri-imp...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Ethics declarations : Investigation of peri-implan...

This study was conducted in compliance with the principles of the Declaration of Helsinki, and the approval of the ethics committee required for the study was obtained from the Ethics Committee of the Medical Center of the Goethe University Frankfurt. The procedures to be performed were explained in detail, and the patients signed the consent form. Jonas Lorenz, Henriette Lerner, Robert Sader, an...

Author information : Investigation of peri-implant...

Department for Oral, FORM-Lab, Cranio-Maxillofacial, and Facial Plastic Surgery, Medical Center of the Goethe University Frankfurt, Frankfurt am Main, Germany Jonas Lorenz, Robert A. Sader & Shahram Ghanaati HL-Dentclinic, Baden-Baden, Germany Henriette Lerner You can also search for this author in PubMed Google Scholar You can also search for this author in ...

References : Investigation of peri-implant tissue ...

Lerner H, Lorenz J, Sader R, Ghanaati S. Two-year retrospective study of periimplant health and periimplant bone stability after immediate implant placement of a newly developed bone level implant system—a first report. EDI Journal (European Association of Dental Implantologists, Teamwork Media); 2017; ahead of print. Ghanaati S, Lorenz J, Obreja K, Choukroun J, Landes C, Sader R. Nanocrystalli...

References : Investigation of peri-implant tissue ...

Gurgel BC, Montenegro SC, Dantas PM, Pascoal AL, Lima KC, Calderon PD. Frequency of peri-implant diseases and associated factors. Clin Oral Implants Res. 2016; doi: 10.1111/clr.12944 Qian J, Wennerberg A, Albrektsson T. Reasons for marginal bone loss around oral implants. Clin Implant Dent Relat Res. 2012;14(6):792–807. Berglundh T, Lindhe J, Ericsson I, Marinello C, Liljenberg B, Thomsen P....

Abbreviations : Investigation of peri-implant tiss...

β-tricalcium phosphate Bleeding on probing Fixed prosthetics Guided bone regeneration Hydroxyapatite Multinucleated giant cells Pink Esthetic Score Removable prosthetics

Conclusions : Investigation of peri-implant tissue...

In the present study, the implant and peri-implant hard- and soft-tissue stability was analyzed in a bone level implant system placed simultaneously with a GBR procedure 3 years after prosthetic loading. Peri-implant hard- and soft-tissue parameters such as width and thickness of peri-implant keratinized gingiva, probing depth, BOP, PES, peri-implant bone loss, and the presence of peri-implant os...

Discussion : Investigation of peri-implant tissue ...

Comparing the present results to the aforementioned study with the same implant system on immediately placed implants, it seems that the GBR augmentation procedure has no influence on the long-term stability of the implants. In both studies with different placement modalities and protocols, comparable clinical and radiological results were achieved. This leads to the assumption that the investigat...

Discussion : Investigation of peri-implant tissue ...

The tissue reaction, however, did not only differ in bone substitute materials of different origin but also in bone substitute materials of the same origin. In an in vivo trial, two xenogeneic bone substitute materials processed with different techniques were implanted subcutaneously in CD-1 mice for up to 60 days. Both bone substitute materials showed good integration within the peri-implant tis...

Discussion : Investigation of peri-implant tissue ...

In the present retrospective study, C-Tech bone level implants placed simultaneously with a GBR procedure around the implant shoulder were investigated clinically and radiologically after at least 3 years of loading to assess peri-implant tissue conditions and document peri-implant tissue stability. A total of 47 implants were placed in the upper (23 implants) and lower jaw (24 implants) of 20 p...

Results : Investigation of peri-implant tissue con...

Investigation of the esthetic appearance via PES revealed a mean point score of 10.1 (ranging from 7 to 13) from a maximum of 14. The highest values and therefore acceptance were found in the alveolar process deficiency and the soft-tissue level, which can be interpreted as a benefit of the augmentation procedure around the implant shoulder. Peri-implant bone loss calculated using the average bon...

Results : Investigation of peri-implant tissue con...

Altogether, 47 implants were placed in the upper and lower jaws of a total of 20 patients. In all implants, lateral augmentation in a GBR process was performed simultaneously with implant placement due to reduced horizontal or vertical height of the alveolar crest. A total of 23 implants were placed in the upper jaw and 24 implants in the lower jaw. The implant diameter varied between 3.5 mm (32 ...

Methods : Investigation of peri-implant tissue con...

Investigation parameters: Implant being in situ Width and thickness of peri-implant keratinized gingiva Pink Esthetic Score (PES) Probing depth BOP Peri-implant bone loss Presence of peri-implant osteolysis

Methods : Investigation of peri-implant tissue con...

In the present retrospective study, bone level implants (C-Tech Esthetic Line implants) were investigated clinically and radiologically. The bone level implant system has a Morse-locking conical implant-abutment connection with platform switching and an indexing hex that allows subcrestal implant placement and aims to prevent peri-implant bone loss. The surface of the implant system is manufacture...

Methods : Investigation of peri-implant tissue con...

In the present retrospective study, 47 dental implants (C-Tech Esthetic Line implants) from 20 patients (11 female, 9 male) with a mean age of 58.5 years (45–75 years) were analyzed clinically and radiologically. Implant placement and follow-up investigation was performed at the HL Dentclinic in Baden-Baden, Germany. The study was approved by the ethics commission of the medical department of ...

Background : Investigation of peri-implant tissue ...

The aim of the present retrospective investigation was to assess clinically and radiologically peri-implant tissue conditions and document peri-implant tissue stability in C-Tech implants when placed simultaneously with a GBR augmentation procedure after at least 3 years of loading.

Background : Investigation of peri-implant tissue ...

The ability of bone substitute materials to form a sufficient and stable implantation bed has been proven in numerous clinical trials; however, it is still to a certain degree unclear if the different tissue reactions have an impact on the establishment of a peri-implant infection, especially when these biomaterials are used for augmentations around the implant shoulder. Due to the two-stage desig...

Background : Investigation of peri-implant tissue ...

The prevalence of peri-implantitis has grown in the past few years and has become a major issue in implant dentistry. Long-term stable and healthy soft- and hard-tissue conditions should be achieved in combination with esthetically and functionally satisfying results. However, the rising number of placed implants in the past decades has come with an increase in the prevalence of peri-implantitis [...

Abstract : Investigation of peri-implant tissue co...

Guided bone regeneration (GBR) has been proven to be a reliable therapy to regenerate missing bone in cases of atrophy of the alveolar crest. The aim of the present retrospective analysis was to assess peri-implant tissue conditions and document peri-implant tissue stability in C-Tech implants when placed simultaneously with a GBR augmentation procedure. A total of 47 implants, which were placed ...

Figure 2. Clinical image of patient 4

  Figure 2. Clinical image of patient 4: a region 21 before implant placement. b, c Implant placement using the GBR procedure with a synthetic bone substitute material composed of HA + β-TCP

Figure 1. Schematic representation of the technica...

    Figure 1. Schematic representation of the technical characteristics of the investigated C-Tech Esthetic Line implant system (provided by the manufacturer)

Table 2 Results from the clinical and radiological...

Patient Implant-localization (region) Implant loss (+/−) Buccal width of keratinized peri-implant gingiva (mm) Buccal thickness of keratinized peri-implant gingiva (mm) Pink Esthetic Score (PES) Probing depth (mm) at four sites (mb, db, mo, do) Bleeding on Probing (+/−) at four sites (mb, db, mo, do) Peri-implant bone loss (mm) Presence of peri-implant osteolysis (+/−) ...

Table 1 Participating patients and the number and ...

Patient Gender (m/f) Age (years) Implant localization (region) Implant diameter (mm) Implant length (mm) Augmentation material Prosthetic rehabilitation 1 f 50 32 3.5 13 HA + β-TCP r.p       34 4.3 11 HA + β-TCP r.p       42 3.5 13 HA + β-TCP r.p       44 4.3 11 HA + β-TCP r.p 2 m 61 36 3.5 11 HA + β-TCP ...

Discussion: Investigation of peri-implant in impla...

Abbreviations β-TCP: β-tricalcium phosphate BOP: Bleeding on probing F.P.: Fixed prosthetics GBR: Guided bone regeneration HA: Hydroxyapatite MNGCs: Multinucleated giant cells PES: Pink Esthetic Score R.P.: Removable prosthetics References Gurgel BC, Montenegro SC, Dantas PM, Pascoal AL, Lima KC, Calderon PD. Frequency o...

Discussion: Investigation of peri-implant in impla...

Comparing the present results to the aforementioned study with the same implant system on immediately placed implants, it seems that the GBR augmentation procedure has no influence on the long-term stability of the implants. In both studies with different placement modalities and protocols, comparable clinical and radiological results were achieved. This leads to the assumption that the inve...

Discussion: Investigation of peri-implant in impla...

The tissue reaction, however, did not only differ in bone substitute materials of different origin but also in bone substitute materials of the same origin. In an in vivo trial, two xenogeneic bone substitute materials processed with different techniques were implanted subcutaneously in CD-1 mice for up to 60 days. Both bone substitute materials showed good integration within the peri-impla...

Discussion: Investigation of peri-implant in impla...

Discussion In the present retrospective study, C-Tech bone level implants placed simultaneously with a GBR procedure around the implant shoulder were investigated clinically and radiologically after at least 3 years of loading to assess peri-implant tissue conditions and document peri-implant tissue stability. A total of 47 implants were placed in the upper (23 implants) and lower jaw (24...

Results: Investigation of peri-implant in implants

Results Altogether, 47 implants were placed in the upper and lower jaws of a total of 20 patients. In all implants, lateral augmentation in a GBR process was performed simultaneously with implant placement due to reduced horizontal or vertical height of the alveolar crest. A total of 23 implants were placed in the upper jaw and 24 implants in the lower jaw. The implant diameter varied between 3...

Methods: Investigation of peri-implant in implants...

C-Tech implant system In the present retrospective study, bone level implants (C-Tech Esthetic Line implants) were investigated clinically and radiologically. The bone level implant system has a Morse-locking conical implant-abutment connection with platform switching and an indexing hex that allows subcrestal implant placement and aims to prevent peri-implant bone loss. The surface of the implan...

Methods: Investigation of peri-implant in implants...

Methods Patient population In the present retrospective study, 47 dental implants (C-Tech Esthetic Line implants) from 20 patients (11 female, 9 male) with a mean age of 58.5 years (45–75 years) were analyzed clinically and radiologically. Implant placement and follow-up investigation was performed at the HL Dentclinic in Baden-Baden, Germany. The study was approved by the ethics commissio...

Background: Investigation of peri-implant in impla...

Regarding the stability of peri-implant hard and soft tissue, biological or anatomical factors are not the only elements that could be proven to have an impact. Technical factors such as the implant-abutment connection are also known to be key factors for long-term stable hard- and soft-tissue health [11]. Regarding the implant-abutment connection, which seems to be the key issue, located on the i...

Background: Investigation of peri-implant in impla...

However, in most patients, the local bone amount is reduced due to atrophy, inflammatory processes, or resectional defects. Therefore, in the past few years, different techniques have been described to enlarge the local bone amount in prospective implant sites [7]. Besides methods such as GBR or the sinus augmentation technique, different augmentation materials have been investigated and establish...

Background: Investigation of peri-implant in impla...

Background   The prevalence of peri-implantitis has grown in the past few years and has become a major issue in implant dentistry. Long-term stable and healthy soft- and hard-tissue conditions should be achieved in combination with esthetically and functionally satisfying results. However, the rising number of placed implants in the past decades has come with an increase in the prevalence of ...

Investigation of peri-implant in implants

Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system Abstract Background Guided bone regeneration (GBR) has been proven to be a reliable therapy to regenerate missing bone in cases of atrophy of the alveolar crest. T...

Figure 3. Data from the VAS of patient-related out...

  Figure 3. Data from the VAS of patient-related outcome measures at the time of mounting of the implant-supported crown and at the final follow-up of the PRF and control group

Figure 2. Box plot of the radiographic peri-implan...

  Figure 2. Box plot of the radiographic peri-implant marginal bone level at different time points in millimeter. Baseline: the time of implant placement; abutment: the time of abutment operation; impression: the time of impression taking; follow-up: the time of the final follow-up

Figure 1. Intraoperative photos illustrating bone ...

  Figure 1. Intraoperative photos illustrating bone harvesting and lateral bone augmentation in the PRF group. Initially, an incision is made at the lateral aspect of the posterior part of the mandibular corpus (a) followed by exposing the mucoperiosteal flap (b), before making the osteotomy line (c). The bone block (d) is then retrieved before adjusted to the contour at the recipient site and...

Table 4 Patient-related outcome measures at baseli...

Table 4 Patient-related outcome measures at baseline and at the final follow-up   Test group Control group Difference p value Mean (95% CI) Mean (95% CI) Mean (95% CI) Baseline 9.44 (9.09 to 9.78) 9.57 (9.20 to 9.95) 0.13 (− 0.40 to 0.66) 0.61 Follow-up 9.66 (9.30 to 10.02) 9.55 (9.15 to 9.96) − 0.10 (-0.66 to 0.46) 0.71 Difference 0.22 (...

Table 3 Radiographic marginal bone level and clini...

Table 3 Radiographic marginal bone level and clinical recession on neighbouring tooth surface Group Baseline (mean, 95% CI) Follow-up (mean, 95% CI) Difference (mean, 95% CI) p value Radiographic marginal bone level in mm  Test 1.94 (1.50 to 2.38) 2.07 (1.64 to 2.51) − 0.14 (− 0.25 to − 0.02) p = 0.03  Control 2.34 (1.62 to 3.08) 2.49 (1.73...

Table 2 Radiographic peri-implant marginal bone le...

Table 2 Radiographic peri-implant marginal bone level in mm Test group Control group Mean difference 95% CI p value Obs Mean 95% CI Obs Mean 95% CI Baseline 14 − 0.24 − 0.48 to 0.00 13 − 0.28 − 0.52 to 0.03 0.04 − 0.314 to 0.39 p = 0.82 Abutment 14 0.07 − 0.17 to 0.30 13 − 0.01 − 0.26 to 0.25 0.08 − 0.278...

Table 1 Demographics and survival rates of implant...

Table 1 Demographics and survival rates of implants and implant crowns   Test group (PRF) Control group Number of implants 14 13 Mean age, years (range) 47.9 (23–66) 52.3 (24–72) Gender  Female 6 6  Male 8 7 Smokers Total 2 1   20 cigarettes per day 1 1 Number of implants 14 13 Implant length (mm) and imp...

Abbreviations & References: A clinical and radiogr...

Abbreviations ASC: Angulated screw channel BOP: Bleeding on probing DBBM: Deproteinised bovine bone mineral GBR: Guided bone regeneration ICC: Intraclass correlation coefficient KT: Keratinised peri-implant tissue PCR: Plaque control record PD: Probing depth PRF: Platelet-rich fibrin PROM: Patient-related outcome measures RCF: ...

Discussion: A clinical and radiographic study of i...

A minor, but statistically significant, radiographic bone loss occurred from baseline to the final follow-up at the neighbouring tooth surfaces in both groups. Moreover, both groups experienced a minor recession of the marginal gingiva from baseline to the final follow-up, but the change was not significant. Recession and the bone level of the neighbouring tooth surfaces to implants placed in ...

Discussion: A clinical and radiographic study of i...

The combination of the NobelParallel CC implant launched in 2015 and an abutment with ASC is relatively new and has so far been lined to only few mechanical problems [39, 40], among which rotation of the crown when torqueing the abutment screw was not stated. In both patients, a new implant was placed without any need for additional bone augmentation and without further complications. ...

Discussion: A clinical and radiographic study of i...

Discussion The present study focused on clinical and radiographic characteristics of staged implants placed in autogenous bone grafts covered by either a PRF membrane (PRF group) or a standard procedure (gold standard) involving coverage of the autogenous bone graft using a deproteinised bovine bone mineral and a resorbable collagen membrane (control group). The PRF group demonstrated a hi...

Results: A clinical and radiographic study of impl...

One patient (control group) expressed minimally changed extraoral sensation in the chin region at both the 1- and 2-week follow-up. However, the extra- and intraoral clinical examination revealed no sensory disturbances. The patient was not affected by this and described the same changed sensation at the final clinical follow-up after 29 months. Another patient (PRF group) experienced sensory d...

Results: A clinical and radiographic study of impl...

Radiographic peri-implant marginal bone change The mean peri-implant marginal bone level at the different time points is shown in Table 2 and Fig. 2. The mean marginal bone level at follow-up was 0.26 mm (95% CI: 0.01–0.50 mm) in the PRF group and 0.68 mm (95% CI: 0.41–0.96 mm) in the control group. The difference between the groups was − 0.43 mm (95% CI: − 0.80 to − 0....

Results: A clinical and radiographic study of impl...

Bleeding on probing The estimated probability or observed proportion of BOP for implants was 0.31 (95% CI: 0.14–0.70) in the PRF group and 0.30 (95% CI: 0.12–0.77) in the control group. The ratio of the probability of observing BOP was 1.046 (95% CI: 0.91–1.20), indicating that the probability of observing BOP is 4.6% higher in the PRF group than in the control group. No statistical differe...

Results: A clinical and radiographic study of impl...

Results Implant survival Two of the 27 initially placed implants were lost in the control group (Table 1). Twenty months after placement of the implant-supported crown, one implant (first premolar, regular platform (4.3 mm), length: 13 mm) was lost due to failed osseointegration. No periodontitis or peri-implant marginal bone resorption was obvious at the time of implant removal. A second...

Material & methods: A clinical and radiographic st...

The distance from the implant-abutment connection to the peri-implant marginal bone level was measured mesially and distally in parallel with the long axis of the implant using open-source software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The distance from the cemento-enamel junction to the marginal bone level at the neighbouring tooth surfaces was also measured in parallel with...

Material & methods: A clinical and radiographic st...

Prosthodontic treatment Forty-nine days (range: 27–113 days) after placement of the healing abutment, the abutment was removed and the implant position was registered by an impression coping on the implant. The final implant-supported restoration was fabricated by using an individually designed angulated screw channel (ASC) zirconium abutment (Nobel Biocare®, Zürich, Switzerland) and venee...

Material & methods: A clinical and radiographic st...

  Methylprednisolone was prescribed the following morning (16 mg) and evening (16 mg). Additionally, postoperative ibuprofen (400 mg, four times daily) and paracetamol (1000 mg, four times daily) were prescribed for 1 week. The patients were instructed to rinse with 0.12% chlorhexidine digluconate twice daily and discontinue the use of their prostheses (if any). Patients were seen for ...

Material & methods: A clinical and radiographic st...

The bone graft was retrieved by making a continuous osteotomy line with a cylindrical and a round bur at the lateral part of the mandible, with a uniform size of approximately 15 × 25 mm (Fig. 1c, d). The bone block containing mainly cortical bone was then gently separated from the mandible using a raspartorium. The block graft was covered with a saline-moistened gauze until used. In the PRF g...

Material & methods: A clinical and radiographic st...

At the time of the bone augmentation procedure, two patients (14%) in the PRF group and one (8%) patient in the control group were smokers. Patients were partially edentulous due to trauma (n = 22), agenesis (n = 3) or marginal periodontitis [2]. Two patients were unavailable for the final follow-up. The referring dentist followed the non-attenders, and telephone interview revealed no subjective o...

Material & methods: A clinical and radiographic st...

Material and methods   The study was performed according to the Declaration of Helsinki and internationally accepted guidelines for RCT, including the CONSORT statement (www.consort-statement.org). The volumetric changes of the augmented bone [26], the histological composition of the augmented bone [27] and pain after the primary bone augmentation procedure [28] were previously described in d...

Background: A clinical and radiographic study of i...

Despite the shape of a membrane, the PRF membrane does not have the properties of a resorbable barrier membrane [21, 22], due to its fast degradation in the same manner as a natural blood clot (1–2 weeks) [23]. Therefore, the PRF membrane is not believed to replace a barrier membrane in the classic understanding of guide bone regeneration (GBR), but rather to enhance the healing capacity of t...

Background: A clinical and radiographic study of i...

Background Implant-supported single crowns are characterised by high long-term survival and few biological and technical complications, which typically includes peri-implant marginal bone loss, screw-loosening and fracture of veneering material complications [1,2,3]. To achieve a successful treatment outcome, the implants must be inserted in sufficient bone volume of an adequate quality to obta...

A clinical and radiographic study of implants plac...

A clinical and radiographic study of implants placed in autogenous bone grafts covered by either a platelet-rich fibrin membrane or deproteinised bovine bone mineral and a collagen membrane: a pilot randomised controlled clinical trial with a 2-year follow-up   Abstract Purpose To compare the survival and clinical performance of implants placed in sites previously augmented with autogenous ...