Table 6 Cox regression analyses for cumulative incidence of peri-implantitis : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
Table 6 Cox regression analyses for cumulative incidence of peri-implantitis : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
author: Tadashi Horikawa, Tetsurou Odatsu, Takatoshi Itoh, Yoshiki Soejima, Hutoshi Morinaga, Naruyoshi Abe, Naoyuki Tsuchiya, Toshikazu | publisher: drg. Andreas Tjandra, Sp. Perio, FISID
Hazard ratio | 95% confidence interval | p value | |
---|---|---|---|
Gender (male) | 2.38 | 1.138~5.362 | 0.0208 |
Implant type (TPS) | 4.35 | 1.897~9.941 | 0.0006 |
Implant position (maxilla to mandibular/anterior) | 6.08 | 1.384~24.436 | 0.0188 |
Implant position (maxilla to mandibular/posterior) | 3.45 | 0.903~11.111 | 0.0679 |
Implant position (mandibular/anterior to mandibular/posterior) | 0.57 | 0.207~1.442 | 0.2370 |
Additional soft tissue management (yes) | 1.18 | 0.535~2.714 | 0.6826 |
Width of keratinized mucosa (> 2 mm) | 0.24 | 0.094~0.559 | 0.0006 |
Table 6 Cox regression analyses for cumulative incidence of peri-implantitis
Serial posts:
- Abstract : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Background : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Methods : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Results : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [1]
- Results : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [2]
- Discussion : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [1]
- Discussion : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [2]
- Discussion : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [3]
- Discussion : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [4]
- Conclusions : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- References : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [1]
- References : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [2]
- References : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [3]
- References : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [4]
- Author information : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [1]
- Author information : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function [2]
- Ethics declarations : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Rights and permissions : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- About this article : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 1 Age and gender distributions (n = 92) : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 2 Distribution of implants in situ (n = 223) : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 3 Distribution of implants by diameter and location (n = 223) : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 4 Distribution of implants by length and location (n = 223) : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 5 Cox regression analyses for implant survival : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 6 Cox regression analyses for cumulative incidence of peri-implantitis : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Table 7 Cox regression analyses for cumulative survival rate of complication-free prostheses : Retrospective cohort study of rough-surface titanium implants with at least 25 years’ function
- Fig. 1. Kaplan-Meier cumulative survival rate at 10, 15, and 25 years after the prosthesis setting : Retrospective cohort study of rough-surface titanium implant
- Fig. 2. Kaplan-Meier cumulative survival rates by a gender (p = 0.1049), b implant type (p = 0.6259), c implant position (p < 0.0001), d presence of additional soft tissue management (p = 0.1149), and e width of keratinized mucosa around implant (p = 0.7132). Log rank test was used for assessing statistical significance : Retrospective cohort study of rough-surface titanium implant
- Fig. 3. Cumulative incidence of peri-implantitis : Retrospective cohort study of rough-surface titanium implant
- Fig. 4. Cumulative incidence of peri-implantitis by a gender (p = 0.0221), b implant type (p = 0.0128), c implant position (p = 0.2470), d presence of additional soft tissue management (p = 0.2488), and e width of keratinized mucosa around implant (p = 0.0045). Log rank test was used for assessing statistical significance : Retrospective cohort study of rough-surface titanium implant
- Fig. 5. Kaplan-Meier cumulative survival rate of complication-free prostheses at 10, 15, and 25 years after the prosthesis setting : Retrospective cohort study of rough-surface titanium implant
- Fig. 6. Cumulative survival rate of complication-free prostheses by a gender (p = 0.1220) and b type of prostheses (p < 0.0001). Log rank test was used for assessing statistical significance : Retrospective cohort study of rough-surface titanium implant