Open hour: senin - sabtu 09:00:00 - 20:00:00; minggu & tanggal merah tutup

Figure 5. Proportion of the occlusal contact area ...

  Figure 5. Proportion of the occlusal contact area and occlusal load of the whole molar region accounted for by the implant prosthesis and by the contralateral tooth

Figure 4. Comparison of the first molar-eliminated...

Figure 4. Comparison of the first molar-eliminated occlusal contact area and load between the implant side molar region and contralateral side molar region

Figure 3. Comparison of the occlusal contact area ...

Figure 3. Comparison of the occlusal contact area and occlusal load between the implant side molar region and contralateral side molar region

Figure 2. Comparison of occlusal contact area and ...

  Figure 2. Comparison of occlusal contact area and occlusal load between implant and contralateral tooth

Figure 1. Comparison of the occlusal contact area ...

Figure 1. Comparison of the occlusal contact area between Occluzer and BiteEye

Table 8 Two-way ANOVA of the proportion of occlusa...

Table 8 Two-way ANOVA of the proportion of occlusal load and contact area for implants and first molars based on molar area   Source Sum of square df Mean square F value P value Occlusal load              Occluzer Implant or natural tooth 585.390 1 585.390 9.870 0.014 MVC 53.901 3 53.901 1.768 0.220 Interaction 46.872 3 46.872 3.79...

Table 6 Two-way ANOVA of the occlusal contact area...

Table 6 Two-way ANOVA of the occlusal contact area of the implant side molar region and contralateral side molar region excluding the first molar     Source Sum of square df Mean square F value P value Occluzer Implant side and contralateral side 2.177 1 2.177 0.383 0.165 MVC 90.753 3 30.251 25.800 0.553 Interaction 9.011 3 3.004 2.209 0.113 ...

Table 5 Two-way ANOVA of occlusal load of the impl...

Table 5 Two-way ANOVA of occlusal load of the implant side molar region and contralateral side molar region Source Sum of square df Mean square F value P value Implant side and contralateral side 8578.099 1 8578.099 1.354 0.278 MVC 193,888.518 3 64,629.506 36.593 0.000 Interaction 30,575.358 3 4016.245 3.153 0.430

Table 4 Two-way ANOVA of the occlusal contact area...

Table 4 Two-way ANOVA of the occlusal contact area of the implant side molar region and contralateral side molar region     Source Sum of square df Mean square F value P value Occluzer Implant side and contralateral side 24.453 1 24.453 2.334 0.165 MVC 159.749 3 53.253 26.918 0.000 Interaction 16.135 3 5.378 3.786 0.024 BiteEye Implant side ...

Table 3 Two-way ANOVA of occlusal load of implant ...

Table 3 Two-way ANOVA of occlusal load of implant prosthesis and contralateral tooth   Source Sum of square df Mean square F value P value Implant or natural tooth 8732.252 1 8732.252 13.299 0.007 MVC 14,619.565 3 4872.855 16.724 0.001 Interaction 2200.789 3 733.596 8.442 0.001

Table 2 Two-way ANOVA of the occlusal contact area...

  Source Sum of square df Mean square F value P value Occluzer Implant or natural tooth 1941.060 1 1941.060 1.074 0.333 MVC 424.098 3 141.336 1.958 0.147 Interaction 262.581 3 87.527 1.345 0.283 BiteEye Implant or natural tooth 28.022 1 28.022 6.892 0.030 MVC 3.374 2 1.687 1.927 0.178 Interaction 0.916 2 0.458 0.827 0.4...

Table 1 Site of implants

No. Sex Age Implant system Implant site 1 F 35 Straumann Right 2 F 39 Brånemark Left 3 F 47 Brånemark Left 4 F 49 Brånemark Left 5 M 43 Straumann Right 6 M 46 Straumann Right 7 M 69 Straumann Right 8 M 48 Brånemark Left 9 M 67 Brånemark Right

Discussion : Occlusal status of implant superstruc...

Measurement of occlusal contact area of implant prosthesis Dental Prescale has a thickness of approximately 100 μm, whereas Blue Silicone has less thickness and is therefore likely to give more accurate measurements of the occlusal contact area. In addition, when the occlusal contact areas of implant prostheses and their contralateral teeth were compared, the occlusal contact area of the c...

Discussion : Occlusal status of implant superstruc...

Measurement of occlusal contact area of implant prosthesis Dental Prescale has a thickness of approximately 100 μm, whereas Blue Silicone has less thickness and is therefore likely to give more accurate measurements of the occlusal contact area. In addition, when the occlusal contact areas of implant prostheses and their contralateral teeth were compared, the occlusal conta...

Discussion : Occlusal status of implant superstruc...

  Measurement of occlusal load Occlusal load was measured with Dental Prescale and analyzed with Occluzer. The Dental Prescale system allows occlusal contact pressure to be measured quickly and easily across the dentition, and it is of enormous clinical utility because its accuracy and reproducibility in the molar region have been confirmed. The technique using this sequence and also the ...

Discussion : Occlusal status of implant superstruc...

  Discussion Subjects and dentition Males outnumbered females in the present study, but there have been no reports of differences in mean occlusal load between males and females in the 50–54 age group. While there have been reports that in healthy, dentulous subjects, the total occlusal force in the molar region on one side is approximately 400 N at maximum clenching st...

Results : Occlusal status of implant superstructur...

Comparison of proportion of occlusal contact area and occlusal load on the molar region accounted for by prosthetic implant and contralateral tooth With both BiteEye and Occluzer, the proportion of the occlusal contact area on the molar region overall accounted for by the prosthetic implant was less than the proportion accounted for by the contralateral natural tooth, and ANOVA showed this differ...

Results : Occlusal status of implant superstructur...

    Comparison of implant side and contralateral side molar regions Comparison of occlusal contact area in the molar region The occlusal contact area in the molar region on the implant and contralateral sides increased with clenching strength and, at clenching intensity of 60 % MVC or above, was less on the implant side molar region (Fig. 3). ANOVA results (Table 4) showed no...

Results : Occlusal status of implant superstructur...

  Comparison of occlusal contact areas evaluated using Occluzer and BiteEye Occlusal contact area values obtained with BiteEye and Occluzer at clenching intensities from 20 to 100 % MVC were compared (Fig. 1). At different clenching intensities, the contact area values of BiteEye with silicone thickness of 10 μm (BE 10 μm) were the most si...

Methods : Occlusal status of implant superstructur...

Analysis of the results from Occluzer and BiteEye The following calculations were performed: Comparison of Occluzer and BiteEye in the occlusal contact area Comparison of the occlusal contact area and occlusal load between the implant and same number of natural teeth on the contralateral side Comparison of the occlusal contact area and occlusal load between molar area...

Methods : Occlusal status of implant superstructur...

Measurement of occlusal contact area using BiteEye A material for checking accuracy of fit (Blue Silicone®; GC, Tokyo, Japan) was used to examine the occlusal contact in the intercuspal position. The occlusal contact area was measured once at each clenching strength (20, 40, and 60 % MVC) using visual feedback. Subject posture was the same as during Prescale measurement....

Methods : Occlusal status of implant superstructur...

Electromyograph attachment Masseter muscle activity was measured using an electromyograph (PowerLab; ADInstruments, Nagoya, Japan). Silver disk electrodes of 10 mm in diameter with bipolar leads (Duotrode; Morita Corp., Osaka, Japan) were adhered on both sides of the central part of the masseter muscle. The distance between electrodes was 21 mm, and the electrodes were pl...

Methods : Occlusal status of implant superstructur...

Methods Subjects and dentition Subjects were nine outpatients (5 male, 4 female) attending Showa University Dental Hospital, aged 35–69 years (mean age, 49 ± 12 years) (Table 1). All subjects were cases of single implants placed at the mandibular first molar deficit, on the day of implant prosthesis setting and occlusal adjustment. The criteria for subject selection were no inflammatory...

Background : Occlusal status of implant superstruc...

Background Implants maintain osseointegration with the inside of the bone over long periods of time, and mechanical factors are important for retaining function. Particularly, when natural teeth and implants are present together, differences in tissue displaceability when they are subjected to occlusal force may cause dynamic imbalance from strong to weak clenchi...

Occlusal status of implant superstructures at mand...

Abstract Background Occlusal contact on the implant superstructures is important for successful treatment. The purpose of this study was to investigate the occlusal contact of single implant superstructures at the mandibular first molar immediately after seating from weak to strong clenching. Methods Subjects were nine patients who had just been fitted with an implant prosthesis in the mandi...