Ethics declarations : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
Ethics declarations : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
author: Paolo Trisi, Antonello Falco, Marco Berardini | publisher: drg. Andreas Tjandra, Sp. Perio, FISID
The Ethics Committee for Animal Research of the Veterinary School of the University of Teramo (Teramo, Italy) approved the study protocol with the protocol number 8110.
The Ethics Committee for Animal Research of the Veterinary School of the University of Teramo (Teramo, Italy) approved the study protocol with the protocol number 8110.
The authors declare that they have no competing interests.
Serial posts:
- Abstract : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Introduction : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [1]
- Introduction : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [2]
- Materials and methods : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [1]
- Materials and methods : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [2]
- Materials and methods : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [3]
- Results : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Discussion : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [1]
- Discussion : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [2]
- Conclusions : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Availability of data and materials : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- References : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [1]
- References : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [2]
- References : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study [3]
- Acknowledgements : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Funding : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Author information : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Ethics declarations : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Additional information : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Rights and permissions : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- About this article : Single-drill implant induces bone corticalization during submerged healing: an in vivo pilot study
- Table 1 Basal bone volume percentage (basal %BV) was compared to %BV around implants after 2 months of healing in both groups. %BV in the test group was significantly higher than basal %BV (P < 0.05)
- Table 2 Mean values of histomorphometric parameters (%BIC and %BV) and biomechanical values (VAM, reverse torque, and ISQ) of each implant group : Single-drill implant induces bone corticalization
- Table 3 Statistical comparison (T test) of examined parameters between the test and control groups. The histomorphometric analysis demonstrated significant differences in BIC% and %BV values between
- Figure 1. Test group. The implant achieved a high osseointegration degree. The newly formed bone appeared well interconnected with the pre-existing trabeculae. The “corticalization” phenomenon is evident: the bone appears densified around a titanium implant (magnification × 8—toluidine blue) : Single-drill implant
- Figure 2. Test group. Implants in the test group showed an extremely high percentage of bone directly contacted to implant surface (magnification × 25—toluidine blue) : Single-drill implant
- Figure 3. Test group. The present histological photo showed a continuous thin layer of newly formed bone along the neck area of the implant (magnification × 25—toluidine blue) : Single-drill implant
- Figure 4. Control group. No bone condensation was possible with traditional burs and standard implant (magnification × 25—toluidine blue) : Single-drill implant
- Figure 5. Control group. Implants belonging to the control group showed some small surface areas not contacted with bone (magnification × 25—toluidine blue) : Single-drill implant
- Figure 6. Control group. Some implant thread areas were not covered by bone layer (magnification × 25—toluidine blue) : Single-drill implant