... the diameter of an implant has greater influence on primary stability than implant length.

Introduction : Novel expandable short dental implants (2)

author: Waldemar Reich,Ramona Schweyen,Christian Heinzelmann,Jeremias Hey,Bilal Al-Nawas, Alexander Walter Eckert | publisher: drg. Andreas Tjandra, Sp. Perio, FISID

... the diameter of an implant has greater influence on primary stability than implant length.

Based on in vitro analysis, they concluded additionally that especially in patients with poor bone quality, a variation of implant dimensions is expected to lead to a significant increase of primary stability. Furthermore, stress distribution on short implants is affected by the bone-to-implant contact ratio. Consequently, several options to increase the implant surface of short implants are elaborated, which consecutively enhance the implant stability: thread number, thread shape, thread depth, implant diameter, implant design and surface topography.

It is known that achievement of primary stability is one precondition for osseointegration and treatment success. There are few reports of immediate and early (6 weeks) functional loading of short implants. This is related to good bone quality, implant design or implant site preparation (e.g. under-drilling). However, under-drilling of the crestal aspect may lead to decreased bone-to-implant contact. It is desirable to reduce the periimplant stress on the crestal bone while providing sufficient primary stability for all bone densities.

Therefore, optimisation of the macro- and microdesign of short dental implants to improve the success rate and long-term stability is preferable. In fact, elderly patients with general comorbidity should benefit from the overall short treatment time. As previously shown, the oral health-related quality of life is compromised during the healing period after implant insertion, especially when augmentation procedures are required. For several reasons, the overall treatment time should be reduced in patients with atrophic alveolar ridges.

The purpose of the present study was to clinically analyse the feasibility and safety of a new short dental implant system with an expandable compressive design in the apical region. We hypothesised that the innovative expandable macrodesign of this implant provides a reliable implant success rate and ensures high implant stability in vivo.