Methods : Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region [3]

Methods : Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region [3]

author: Shinya Homma, Yasushi Makabe, Takuya Sakai, Kenzou Morinaga, Satoru Yokoue, Hirofumi Kido, Yasutomo Yajima | publisher: drg. Andreas Tjandra, Sp. Perio, FISID

The CBCT was performed using a 3DX Multi-Image Micro CT FPD 8 system (J. MORITA MFG., Kyoto, Japan) (tube voltage, 80 kV; imaging area, 80 × 80 mm), and voxel values were measured with coDiagnostix™ 9.7 (dental wings, Montreal, Canada). The voxel values were calculated based on CT images for bone quality diagnosis. Voxel values were measured three times at 12 locations covering the mesial, distal, buccal, and lingual sides of each of the neck, middle, and apex parts of the implant treatment area, then average voxel values for each part and for the whole treatment area were calculated (Fig. 2).

All numerical data obtained in this research were statistically analyzed with one-way analysis of variance and multiple comparison tests by Bonferroni et al. [22]. Fisher’s exact test and the corresponding t test were used for statistical analysis of insertion torque values and the relationship between ISQ and insertion torque, respectively [23].