Table 1 BoP, PI, and PPD mean values at baseline, 1 month, and 3 months (Of: Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant)
Table 1 BoP, PI, and PPD mean values at baseline, 1 month, and 3 months (Of: Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant)
author: Giuseppe Allocca, Diana Pudylyk, Fabrizio Signorino, Giovanni Battista Grossi, Carlo Maiorana | publisher: drg. Andreas Tjandra, Sp. Perio, FISID
Baseline | 1 month | 3 months | |
---|---|---|---|
T0 | T1 | T2 | |
BoP implants, test | 46.55% ± 18.41% | 32.31% ± 13.27% | 22.18% ± 11.06% |
BoP implants, control | 32% ± 24.88% | 19.84% ± 15.52% | 19.11% ± 17.30% |
BoP teeth, test | 18.81% ± 15.93% | 8.76% ± 8.11% | 6.5% ± 5.18% |
BoP teeth, control | 21.61% ± 15.38% | 15.50% ± 12.21% | 16.38% ± 11.79% |
PI implants, test | 53.71% ± 14.72% | 33.65% ± 12.57% | 15.52% ± 12.29% |
PI implants, control | 50.13% ± 27.39% | 28.66% ± 16.26% | 32.68% ± 16.02% |
PI teeth, test | 33.15% ± 13.49% | 20.76% ± 10.16% | 14.5% ± 6.74% |
PI teeth, control | 41.34% ± 17.20% | 32.26% ± 15.02% | 35.77% ± 15.80% |
PPD implants, test | 2.73 mm ± 0.59 mm | 2.67 mm ± 0.5 mm | 2.61 mm ± 0.54 mm |
PPD implants, control | 2.4 mm ± 0.97 mm | 2.22 mm ± 0.57 mm | 2.21 mm ± 0.66 mm |
PPD teeth, test | 1.7 mm ± 0.47 mm | 1.69 mm ± 0.38 mm | 1.69 mm ± 0.4 mm |
PPD teeth, control | 2.01 mm ± 0.67 mm | 1.93 mm ± 0.58 mm | 2.04 mm ± 0.52 mm |
Table 1 BoP, PI, and PPD mean values at baseline, 1 month, and 3 months
Serial posts:
- Abstract : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- Introduction : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [1]
- Introduction : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [2]
- Material and methods : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [1]
- Material and methods : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [2]
- Material and methods : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [3]
- Material and methods : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [4]
- Results : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [1]
- Results : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [2]
- Discussion : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [1]
- Discussion : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [2]
- Discussion : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [3]
- Discussion : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [4]
- Conclusions : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- References : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [1]
- References : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [2]
- References : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [3]
- References : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [4]
- References : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data [5]
- Acknowledgements : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- Author information : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- Ethics declarations : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- Rights and permissions : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- About this article : Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data
- Table 1 Distribution of patients with local and systemic risk factors (Of: Retrospective cohort study of a tapered implant)
- Table 2 Clinical parameters and reason for implant failures of 15 implants in 12 patients (Of: Retrospective cohort study of a tapered implant)
- Fig. 1. On Kaplan-Meier survival estimates, the cumulative survival rate was 91.5% : Retrospective cohort study of a tapered implant
- Fig. 2. The cumulative survival rates for the different RF groups revealing a significant difference for patients without any and patients with local and systemic RFs (log rank, p = 0.006) : Retrospective cohort study of a tapered implant
- Abstract : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Background : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Methods : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [1]
- Methods : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [2]
- Results : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [1]
- Results : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [2]
- Discussion : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [1]
- Discussion : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [2]
- Conclusion : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Abbreviations : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- References : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [1]
- References : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [2]
- References : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [3]
- References : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial [4]
- Acknowledgements : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Author information : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Ethics declarations : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Rights and permissions : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- About this article : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial
- Table 1 BoP, PI, and PPD mean values at baseline, 1 month, and 3 months (Of: Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant)
- Fig. 1. Electric toothbrush heads: on the left is the one designed for natural teeth, and on the right is the one designed for dental implants : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 2. Patients’ population flow chart : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 3. PI on dental implants. Test values keep reducing after 1 month while control maintains the same level : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 4. PI on natural teeth. After 1 month, the test group showed mild reduction while control a light improvement : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 5. BoP on dental implants. It can be observed how the values keep decreasing after 1 month only in the test group : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 6. BoP on natural teeth. While the control group shows a mild increase between 1 month and 3 months, the test group values decrease during all the duration of the study : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 7. PPD on dental implants. No significant differences appreciable : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant
- Fig. 8. PPD on natural teeth. No significant differences appreciable : Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implant