Buccal loading Central loading Lingual loading Average
The neck of the implant
 Contact model
  No. 34 9.62 16.43 16.75 14.27
  No. 35 9.39 9.81 6.43 8.54
  No. 36 0.72 0.52 4.04 1.76
 Fixation model
  No. 34 3.36 3.24 5.69 4.10
  No. 35 3.04 0.54 7.03 3.53
  No. 36 4.03 4.44 3.91 4.13
The tip of the implant
 Contact model
  No. 34 17.31 11.83 29.53 19.55
  No. 35 2.83 10.34 13.62 8.93
  No. 36 45.69 45.99 34.13 41.94
 Fixation model
  No. 34 9.67 10.44 2.22 7.45
  No. 35 2.33 4.53 4.43 3.76
  No. 36 18.09 15.09 19.79 17.65