Open hour: senin - sabtu 09:00:00 - 20:00:00; minggu & tanggal merah tutup

Fig. 5. Osteoblasts with an orientation tendency a...

Fig. 5. Osteoblasts with an orientation tendency after 24 h of rotation (phallacidin fluorescence staining). On the left side with 200× and on the right side with 400× magnification. The yellow arrows show the orientation of the cells. The red arched arrow within the coloured circle shows the direction of rotation. The dashed white line oriented to the right stands for the resulting centrifug...

Fig. 4. Randomly orientated osteoblasts without in...

Fig. 4. Randomly orientated osteoblasts without influence of rotation (phallacidin fluorescence staining). On the left side with 200× and on the right side with 400× magnification. The white X on the coloured circle marks the location upon the plate where the osteoblasts were located. The red X marks the centre of the plate Fig. 4. Randomly orientated osteoblasts without influence of rotati...

Fig. 3. Diagram for visualisation of the calculati...

centrifugal force and the glass plates’ dimensions. For example, at a distance of 25 mm from the centre of the upper plate, the shear forces’ value is 8.33 dyn/cm2, together with an additional centrifugal force that has a value of 0.55 dyn/cm2 Fig. 3. Diagram for visualisation of the calculation of shear stress rates taking into account the centrifugal force and the glass plates’ dim...

Fig. 2. Side view of a computerized simulation, sh...

earing gap and bottom plate are shown on the left side; rotation speed = 200 rpm; colour code bar (left edge) showing shear force values [Pa] [1 Pa = 10 dyn/cm2]; flow direction presented by arrows Fig. 2. Side view of a computerized simulation, showing the flow chambers’ lower compartment and the flow profile in between the two plates; shearing gap and bottom plate are shown on ...

Fig. 1. Three-dimensional illustration (a–e) and...

Fig. 1. Three-dimensional illustration (a–e) and photography (f) of the experimental setup with the components marked numerical. a as the lower plate); 2 Rotating glass panel [60 mm diameter (cell bearing)]; 3 Titanium axis. b4 Liquid medium (red). cGearwheel with set screw. eng ring with additional set screw Fig. 1. Three-dimensional illustration (a–e) and photography (f) of the experim...

Table 2 Listing of the culture media and additives...

Culture medium/additives Manufacturer Order no. Concentration Dulbecco’s modified Eagle medium (DMEM) with l-glutamine, plus 4.5 g glucose,...

Table 1 Listing of the single components of the fl...

Component Manufacturer Order no. Large petri dish Becton Dickinson, Franklin Lakes, NJ, USA ...

About this article : Cellular fluid shear stress o...

Kämmerer, P.W., Thiem, D.G.E., Alshihri, A. et al. Cellular fluid shear stress on implant surfaces—establishment of a novel experimental set up. Int J Implant Dent 3, 22 (2017). https://doi.org/10.1186/s40729-017-0085-3 Download citation Received: 27 February 2017 Accepted: 22 May 2017 Published: 31 May 2017 DOI: https://doi.org/10.1186/s40729-017-0085-3

Rights and permissions : Cellular fluid shear stre...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Cellular fluid shear stress o...

Correspondence to D. G. E. Thiem.

Author information : Cellular fluid shear stress o...

Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Rostock, Schillingallee 35, 18057, Rostock, Germany P. W. Kämmerer & D. G. E. Thiem Department of Prosthetic and Biomaterial Sciences, King Saud University, Riyadh, Saudi Arabia A. Alshihri Harvard School of Dental Medicine, Boston, MA, USA A. Alshihri Department of Oral and Maxillofacial Surge...

Acknowledgements : Cellular fluid shear stress on ...

The authors thank the Department of Hydraulic Machines, Faculty of Mechanical Engineering, Technical University of Munich, Germany, for helping with the computerised simulations. Nothing to declare The datasets supporting the conclusions of this article are available at the repository of the University Medical Centre Mainz, Germany, and can be provided on request. PK had substantial contributio...

References : Cellular fluid shear stress on implan...

Papadaki M, Eskin SG. Effects of fluid shear stress on gene regulation of vascular cells. Biotechnol Prog. 1997;13(3):209–21. James NL, Harrison DG, Nerem RM. Effects of shear on endothelial cell calcium in the presence and absence of ATP. FASEB J. 1995;9(10):968–73. Kämmerer PW, Lehnert M, Al-Nawas B, Kumar VV, Hagmann S, Alshihri A, et al. Osseoconductivity of a specific streptavidin-biot...

References : Cellular fluid shear stress on implan...

Hughes-Fulford M. Signal transduction and mechanical stress. Sci STKE. 2004;2004(249):RE12. Ruel J, Lemay J, Dumas G, Doillon C, Charara J. Development of a parallel plate flow chamber for studying cell behavior under pulsatile flow. ASAIO J. 1995;41(4):876–83. Kazakidi A, Sherwin SJ, Weinberg PD. Effect of Reynolds number and flow division on patterns of haemodynamic wall shear stress near br...

References : Cellular fluid shear stress on implan...

Becker J, Kirsch A, Schwarz F, Chatzinikolaidou M, Rothamel D, Lekovic V, et al. Bone apposition to titanium implants biocoated with recombinant human bone morphogenetic protein-2 (rhBMP-2). A pilot study in dogs. Clin Oral Investig. 2006;10(3):217–24. Hung CT, Allen FD, Pollack SR, Brighton CT. What is the role of the convective current density in the real-time calcium response of cultured bon...

References : Cellular fluid shear stress on implan...

Ehrlich PJ, Lanyon LE. Mechanical strain and bone cell function: a review. Osteoporos Int. 2002;13(9):688–700. Vaughan TJ, Haugh MG, Mcnamara LM. A fluid-structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems. J R Soc Interface. 2013;10(81):20120900. Weinbaum S, Cowin SC, Zeng Y. A model for the excitation of osteocytes by mechanical loading-in...

Abbreviations : Cellular fluid shear stress on imp...

Fluid shear stress

Conclusions : Cellular fluid shear stress on impla...

To create fluid shear stress under in vitro conditions, several flow chambers have been developed in the past. The experimental setup of the flow chamber in the centre of this study offers advantages such as simplicity to assemble and ease of use as well as the creation of reproducible fluid shear forces on cells. Due to the new design, different cell types could be simultaneously analysed under r...

Discussion : Cellular fluid shear stress on implan...

Besides, in the model reported in this study, microscopic examinations are possible after completing the experiment only. Nevertheless, an advantage of the new flow chamber is the possibility of testing different cell colonies simultaneously in one single experiment by placing cells in different radial locations on the spinning disc. Due to the current flow gradient from the centre to the peripher...

Discussion : Cellular fluid shear stress on implan...

Due to the fact that constant flows were generated within the parallel flow chamber only, the situations of in vitro experiments differ from in vivo setting where dynamic flow profiles are particular [33]. As the constant laminar flow profile is not physiological in bones [34], vessels and other tissues [35], the informative value of the experimental setting is limited but it could be used for var...

Discussion : Cellular fluid shear stress on implan...

The aim of this study was to establish a new FSS model that is easy to use as well as simple to assemble in order to create reproducible fluid shear forces on cells close to implant material surfaces. Todays’ commonly used commercial flow devices differ in geometry and function, which makes comparisons between experiments difficult [4, 10, 26, 27]. The benefits of this novel testing device are r...

Results : Cellular fluid shear stress on implant s...

in which ρ = density, h = height, ω = angular velocity and r = radius. Figure 3 shows the respective physical force and its dependence on a bigger radius and higher rotational speed. The results of this study indicate that the centrifugal force represents only a little proportion of effective forces. Hence, the centrifugal forces’ impacts on the tested cells are considered to be insignifican...

Results : Cellular fluid shear stress on implant s...

Our analysis was focused on two main aspects: Simulation of the fluid flow characteristics as well as quantification of the arising shear forces at the plate/plate flow chamber with reliable reproducibility Assessment of the impact of fluid shear stress on osteoblast cells in terms of altered cell morphology and intracellular structural changes The computational fluid dynamic analysis and the q...

Methods : Cellular fluid shear stress on implant s...

For constant and fully developed laminar flow between the two parallel plates, the magnitude of the wall shear stress (τ) in between was calculated by formula 1: in which η is the dynamic fluid viscosity (dyn/cm2), r is the radius of the plate (cm), ω stands for angular velocity and H for height (vertical distance in between the two plates). To get information whether the flow is laminar or t...

Methods : Cellular fluid shear stress on implant s...

A three-dimensional illustration and photography of the plate/plate flow chamber model is shown in Fig. 1. A detailed list of used parts can be found in Appendix 1. The circulation within the flow chamber was generated by an externally attached electric motor, which rotates up to 500 rounds per minute (rpm). A commercial grade 4 pure medical titanium gear shaft (length = 40 mm, diameter =...

Background : Cellular fluid shear stress on implan...

Therefore, the aim of the present study was to establish a new cell chamber model for FSS simulation and stimulation. In addition to its ease of use, the reported model in this study should meet the requirements of a simple design, generating reproducible flow characteristics next to laminar flows and clearly defined flow gradients on implant surfaces.

Background : Cellular fluid shear stress on implan...

Cells can be influenced by different mechanostimuli, which lead to an activation of cellular and inter-cellular responses. These reactions may be caused by either a direct stimulation of the cell body (mechanoreception) or indirect cellular stimulation (response) [1,2,3]. Extracellular fluid movement induces fluid shear stress (FSS) that can result in different cellular processes including prolife...

Abstract : Cellular fluid shear stress on implant ...

Mechanostimuli of different cells can affect a wide array of cellular and inter-cellular biological processes responsible for dental implant healing. The purpose of this in vitro study was to establish a new test model to create a reproducible flow-induced fluid shear stress (FSS) of osteoblast cells on implant surfaces. As FSS effects on osteoblasts are detectable at 10 dyn/cm2, a custom-made f...

Fig. 5. Osteoblasts with an orientation tendency a...

Fig. 5. Osteoblasts with an orientation tendency after 24 h of rotation (phallacidin fluorescence staining). On the left side with 200× and on the right side with 400× magnification. The yellow arrows show the orientation of the cells. The red arched arrow within the coloured circle shows the direction of rotation. The dashed white line oriented to the right stands for the resulting centrifug...

Fig. 4. Randomly orientated osteoblasts without in...

Fig. 4. Randomly orientated osteoblasts without influence of rotation (phallacidin fluorescence staining). On the left side with 200× and on the right side with 400× magnification. The white X on the coloured circle marks the location upon the plate where the osteoblasts were located. The red X marks the centre of the plate Fig. 4. Randomly orientated osteoblasts without influence of rotati...

Fig. 3. Diagram for visualisation of the calculati...

to account the centrifugal force and the glass plates’ dimensions. For example, at a distance of 25 mm from the centre of the upper plate, the shear forces’ value is 8.33 dyn/cm2, together with an additional centrifugal force that has a value of 0.55 dyn/cm2 Fig. 3. Diagram for visualisation of the calculation of shear stress rates taking into account the centrifugal force and the glas...

Fig. 2. Side view of a computerized simulation, sh...

e in between the two plates; shearing gap and bottom plate are shown on the left side; rotation speed = 200 rpm; colour code bar (left edge) showing shear force values [Pa] [1 Pa = 10 dyn/cm2]; flow direction presented by arrows Fig. 2. Side view of a computerized simulation, showing the flow chambers’ lower compartment and the flow profile in between the two plates; shearing gap...

Fig. 1. Three-dimensional illustration (a–e) and...

Fig. 1. Three-dimensional illustration (a–e) and photography (f) of the experimental setup with the components marked numerical. a lower plate); 2 Rotating glass panel [60 mm diameter (cell bearing)]; 3 Titanium axis. b4 Liquid medium (red). cwheel with set screw. e ring with additional set screw Fig. 1. Three-dimensional illustration (a–e) and photography (f) of the experimental setup w...

Table 2 Listing of the culture media and additives...

Culture medium/additives Manufacturer Order no. Concentration Dulbecco’s modified Eagle medium (DMEM) with l-glutamine, plus 4.5 g glucose,...

Table 1 Listing of the single components of the fl...

Component Manufacturer Order no. Large petri dish Becton Dickinson, Franklin Lakes, NJ, USA ...

About this article : Cellular fluid shear stress o...

Kämmerer, P.W., Thiem, D.G.E., Alshihri, A. et al. Cellular fluid shear stress on implant surfaces—establishment of a novel experimental set up. Int J Implant Dent 3, 22 (2017). https://doi.org/10.1186/s40729-017-0085-3 Download citation Received: 27 February 2017 Accepted: 22 May 2017 Published: 31 May 2017 DOI: https://doi.org/10.1186/s40729-017-0085-3

Rights and permissions : Cellular fluid shear stre...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Cellular fluid shear stress o...

Correspondence to D. G. E. Thiem.

Author information : Cellular fluid shear stress o...

Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Rostock, Schillingallee 35, 18057, Rostock, Germany P. W. Kämmerer & D. G. E. Thiem Department of Prosthetic and Biomaterial Sciences, King Saud University, Riyadh, Saudi Arabia A. Alshihri Harvard School of Dental Medicine, Boston, MA, USA A. Alshihri Department of Oral and Maxillofacial Surge...

Acknowledgements : Cellular fluid shear stress on ...

The authors thank the Department of Hydraulic Machines, Faculty of Mechanical Engineering, Technical University of Munich, Germany, for helping with the computerised simulations. Nothing to declare The datasets supporting the conclusions of this article are available at the repository of the University Medical Centre Mainz, Germany, and can be provided on request. PK had substantial contributio...

References : Cellular fluid shear stress on implan...

Papadaki M, Eskin SG. Effects of fluid shear stress on gene regulation of vascular cells. Biotechnol Prog. 1997;13(3):209–21. James NL, Harrison DG, Nerem RM. Effects of shear on endothelial cell calcium in the presence and absence of ATP. FASEB J. 1995;9(10):968–73. Kämmerer PW, Lehnert M, Al-Nawas B, Kumar VV, Hagmann S, Alshihri A, et al. Osseoconductivity of a specific streptavidin-biot...

References : Cellular fluid shear stress on implan...

Hughes-Fulford M. Signal transduction and mechanical stress. Sci STKE. 2004;2004(249):RE12. Ruel J, Lemay J, Dumas G, Doillon C, Charara J. Development of a parallel plate flow chamber for studying cell behavior under pulsatile flow. ASAIO J. 1995;41(4):876–83. Kazakidi A, Sherwin SJ, Weinberg PD. Effect of Reynolds number and flow division on patterns of haemodynamic wall shear stress near br...

References : Cellular fluid shear stress on implan...

Becker J, Kirsch A, Schwarz F, Chatzinikolaidou M, Rothamel D, Lekovic V, et al. Bone apposition to titanium implants biocoated with recombinant human bone morphogenetic protein-2 (rhBMP-2). A pilot study in dogs. Clin Oral Investig. 2006;10(3):217–24. Hung CT, Allen FD, Pollack SR, Brighton CT. What is the role of the convective current density in the real-time calcium response of cultured bon...

References : Cellular fluid shear stress on implan...

Ehrlich PJ, Lanyon LE. Mechanical strain and bone cell function: a review. Osteoporos Int. 2002;13(9):688–700. Vaughan TJ, Haugh MG, Mcnamara LM. A fluid-structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems. J R Soc Interface. 2013;10(81):20120900. Weinbaum S, Cowin SC, Zeng Y. A model for the excitation of osteocytes by mechanical loading-in...

Abbreviations : Cellular fluid shear stress on imp...

Fluid shear stress

Conclusions : Cellular fluid shear stress on impla...

To create fluid shear stress under in vitro conditions, several flow chambers have been developed in the past. The experimental setup of the flow chamber in the centre of this study offers advantages such as simplicity to assemble and ease of use as well as the creation of reproducible fluid shear forces on cells. Due to the new design, different cell types could be simultaneously analysed under r...

Discussion : Cellular fluid shear stress on implan...

Besides, in the model reported in this study, microscopic examinations are possible after completing the experiment only. Nevertheless, an advantage of the new flow chamber is the possibility of testing different cell colonies simultaneously in one single experiment by placing cells in different radial locations on the spinning disc. Due to the current flow gradient from the centre to the peripher...

Discussion : Cellular fluid shear stress on implan...

Due to the fact that constant flows were generated within the parallel flow chamber only, the situations of in vitro experiments differ from in vivo setting where dynamic flow profiles are particular [33]. As the constant laminar flow profile is not physiological in bones [34], vessels and other tissues [35], the informative value of the experimental setting is limited but it could be used for var...

Discussion : Cellular fluid shear stress on implan...

The aim of this study was to establish a new FSS model that is easy to use as well as simple to assemble in order to create reproducible fluid shear forces on cells close to implant material surfaces. Todays’ commonly used commercial flow devices differ in geometry and function, which makes comparisons between experiments difficult [4, 10, 26, 27]. The benefits of this novel testing device are r...

Results : Cellular fluid shear stress on implant s...

in which ρ = density, h = height, ω = angular velocity and r = radius. Figure 3 shows the respective physical force and its dependence on a bigger radius and higher rotational speed. The results of this study indicate that the centrifugal force represents only a little proportion of effective forces. Hence, the centrifugal forces’ impacts on the tested cells are considered to be insignifican...

Results : Cellular fluid shear stress on implant s...

Our analysis was focused on two main aspects: Simulation of the fluid flow characteristics as well as quantification of the arising shear forces at the plate/plate flow chamber with reliable reproducibility Assessment of the impact of fluid shear stress on osteoblast cells in terms of altered cell morphology and intracellular structural changes The computational fluid dynamic analysis and the q...

Methods : Cellular fluid shear stress on implant s...

For constant and fully developed laminar flow between the two parallel plates, the magnitude of the wall shear stress (τ) in between was calculated by formula 1: in which η is the dynamic fluid viscosity (dyn/cm2), r is the radius of the plate (cm), ω stands for angular velocity and H for height (vertical distance in between the two plates). To get information whether the flow is laminar or t...

Methods : Cellular fluid shear stress on implant s...

A three-dimensional illustration and photography of the plate/plate flow chamber model is shown in Fig. 1. A detailed list of used parts can be found in Appendix 1. The circulation within the flow chamber was generated by an externally attached electric motor, which rotates up to 500 rounds per minute (rpm). A commercial grade 4 pure medical titanium gear shaft (length = 40 mm, diameter =...

Background : Cellular fluid shear stress on implan...

Therefore, the aim of the present study was to establish a new cell chamber model for FSS simulation and stimulation. In addition to its ease of use, the reported model in this study should meet the requirements of a simple design, generating reproducible flow characteristics next to laminar flows and clearly defined flow gradients on implant surfaces.

Background : Cellular fluid shear stress on implan...

Cells can be influenced by different mechanostimuli, which lead to an activation of cellular and inter-cellular responses. These reactions may be caused by either a direct stimulation of the cell body (mechanoreception) or indirect cellular stimulation (response) [1,2,3]. Extracellular fluid movement induces fluid shear stress (FSS) that can result in different cellular processes including prolife...

Abstract : Cellular fluid shear stress on implant ...

Mechanostimuli of different cells can affect a wide array of cellular and inter-cellular biological processes responsible for dental implant healing. The purpose of this in vitro study was to establish a new test model to create a reproducible flow-induced fluid shear stress (FSS) of osteoblast cells on implant surfaces. As FSS effects on osteoblasts are detectable at 10 dyn/cm2, a custom-made f...

Figure 5. Osteoblasts with an orientation tendency...

  Figure 5. Osteoblasts with an orientation tendency after 24 h of rotation (phallacidin fluorescence staining). On the left side with 200× and on the right side with 400× magnification. The yellow arrows show the orientation of the cells. The red arched arrow within the coloured circle shows the direction of rotation. The dashed white line oriented to the right stands for the r...

Figure 4. Randomly orientated osteoblasts without ...

  Figure 4. Randomly orientated osteoblasts without influence of rotation (phallacidin fluorescence staining). On the left side with 200× and on the right side with 400× magnification. The white X on the coloured circle marks the location upon the plate where the osteoblasts were located. The red X marks the centre of the plate

Figure 3. Diagram for visualisation of the calcula...

  Figure 3. Diagram for visualisation of the calculation of shear stress rates taking into account the centrifugal force and the glass plates’ dimensions. For example, at a distance of 25 mm from the centre of the upper plate, the shear forces’ value is 8.33 dyn/cm2, together with an additional centrifugal force that has a value of 0.55 dyn/cm2

Figure 2. Side view of a computerized simulation

  Figure 2. Side view of a computerized simulation, showing the flow chambers’ lower compartment and the flow profile in between the two plates; shearing gap and bottom plate are shown on the left side; rotation speed = 200 rpm; colour code bar (left edge) showing shear force values [Pa] [1 Pa = 10 dyn/cm2]; flow direction presented by arrows

Figure 1. Three-dimensional illustration and photo...

Figure 1. Three-dimensional illustration (a–e) and photography (f) of the experimental setup with the components marked numerical. a 1 Lower petri dish (s’ bottom serving as the lower plate); 2 Rotating glass panel [60 mm diameter (cell bearing)]; 3 Titanium axis. b 4 Liquid medium (red). c 5 Reversed upper petri dish. d 6 Gearwheel with set screw. e 7 Closing; 8 Electronic motor device and ...

References : Cellular fluid shear stress on implan...

References Ehrlich PJ, Lanyon LE. Mechanical strain and bone cell function: a review. Osteoporos Int. 2002;13(9):688–700. Vaughan TJ, Haugh MG, Mcnamara LM. A fluid-structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems. J R Soc Interface. 2013;10(81):20120900. Weinbaum S, Cowin SC, Zeng Y. A model for the excitation of osteocytes by mec...

Discussion : Cellular fluid shear stress on implan...

Besides, in the model reported in this study, microscopic examinations are possible after completing the experiment only. Nevertheless, an advantage of the new flow chamber is the possibility of testing different cell colonies simultaneously in one single experiment by placing cells in different radial locations on the spinning disc. Due to the current flow gradient from the centre to the pe...

Discussion : Cellular fluid shear stress on implan...

Due to the fact that constant flows were generated within the parallel flow chamber only, the situations of in vitro experiments differ from in vivo setting where dynamic flow profiles are particular. As the constant laminar flow profile is not physiological in bones, vessels and other tissues, the informative value of the experimental setting is limited but it could be used for various cell...

Discussion : Cellular fluid shear stress on implan...

Further on, the simulations indicated that the flow profile in between the two plates was not influenced by peripheral turbulences alongside the peripheral regions. To verify a cellular realignment towards the shear direction, cells were microscopically examined prior and after exposure to shear forces for 24 h upon a spinning disc at a speed level of 200 rpm. Even if not sufficiently ...

Discussion : Cellular fluid shear stress on implan...

Discussion The aim of this study was to establish a new FSS model that is easy to use as well as simple to assemble in order to create reproducible fluid shear forces on cells close to implant material surfaces. Todays’ commonly used commercial flow devices differ in geometry and function, which makes comparisons between experiments difficult. The benefits of this novel testing device are...

Results : Cellular fluid shear stress on implant s...

Regarding the upper compartment, peripheral turbulent flow along the outer edges was similar to the fluid movements within the area in between the plates. At the top, the turbulent flow directed from the centre to the periphery whereas the turbulences at the bottom were orientated in reverse to that. Moreover, the effect of the shear forces on the osteoblast cells was also influenced by the centri...

Results : Cellular fluid shear stress on implant s...

Results Our analysis was focused on two main aspects: Simulation of the fluid flow characteristics as well as quantification of the arising shear forces at the plate/plate flow chamber with reliable reproducibility Assessment of the impact of fluid shear stress on osteoblast cells in terms of altered cell morphology and intracellular structural changes Evaluation of the f...

Methods : Cellular fluid shear stress on implant s...

  Test procedure The experimental process involved three steps. First, a count of n = 50.000 commercially available osteoblasts (PromoCell, Heidelberg, Germany) per millilitre of culture medium were cultured on the bottom of the cell-bearing surface (glass panel). Therefore, cells were seeded in a culture medium (cf. Appendix 2 for a detailed composition) at 37 °C. Prior to the test proce...

Methods : Cellular fluid shear stress on implant s...

  Analytical formula for evaluating the flow characteristics Frequently used flow chambers are characterised by an internal fluid flow along a stationary cell-bearing surface, whereas the osteoblast test cells of this newly developed model are circulating within a resting culture medium. For constant and fully developed laminar flow between the two parallel plates, the magnitude of the wall sh...

Methods : Cellular fluid shear stress on implant s...

Methods Experimental setup A three-dimensional illustration and photography of the plate/plate flow chamber model is shown in Fig. 1. A detailed list of used parts can be found in Appendix 1. The circulation within the flow chamber was generated by an externally attached electric motor, which rotates up to 500 rounds per minute (rpm). A commercial grade 4 pure medical titanium gear shaft (len...

Cellular fluid shear stress on implant surfaces

Abstract Background Mechanostimuli of different cells can affect a wide array of cellular and inter-cellular biological processes responsible for dental implant healing. The purpose of this in vitro study was to establish a new test model to create a reproducible flow-induced fluid shear stress (FSS) of osteoblast cells on implant surfaces. Methods As FSS effects on osteoblasts are detectabl...