Implant-Supported Overdentures: Balancing Stabilit...

The Rise of Implant-Supported Overdentures in Modern Dentistry Implant-supported overdentures represent a revolutionary advancement in restorative dentistry, offering patients a harmonious blend of functional stability and cost-effectiveness . Unlike traditional dentures, which rely solely on soft tissue adhesion, overdentures utilize 2 to 4 strategically placed dental implants to enhance...

Digital Periotest: Measuring Tooth Mobility with P...

Revolutionizing Periodontal Diagnostics with Advanced Technology The field of periodontics has always relied on precision to diagnose and treat periodontal diseases effectively. Traditional methods, while reliable, often lacked the granularity needed to assess early-stage tooth mobility or subtle changes in periodontal health. Today, the Digital Periotest has emerged as a groundbreaking tool,...

How Vitamin C Deficiency Affects Your Gums—and H...

The Critical Role of Vitamin C in Oral Health Vitamin C, or ascorbic acid, is a powerhouse nutrient that plays a vital role in maintaining gum health, collagen synthesis, and immune function. While its benefits are widely recognized in overall wellness, its impact on periodontal tissues is often overlooked. A deficiency in vitamin C can lead to gingival inflammation, delayed wound healing, and...

The Critical Role of the Periodontist in Modern Im...

Why Periodontists Are Essential in Dental Implantology Dental implants have revolutionized restorative dentistry, offering patients a durable, functional, and aesthetically pleasing solution for missing teeth. However, the success of an implant depends on more than just prosthetic design—it hinges on the health of the surrounding periodontal tissues. This is where the periodontist plays an ...

Bone Grafting Procedures Explained for Dental Impl...

Why Bone Grafting Is Essential for Dental Implants Dental implants are a transformative solution for restoring missing teeth, offering unmatched stability and functionality. However, not all patients have sufficient natural bone structure to support implant placement. This is where bone grafting comes into play—a critical procedure that ensures long-term implant success by rebuilding lost b...

Why Is Your Denture Loose During Eating? Common Ca...

Understanding the Challenge of Loose Dentures A loose denture during meals can feel frustrating, but it’s often a sign that your oral appliance needs attention. The good news? Many causes are manageable with proper adjustments, hygiene, or professional care. Whether you rely on full or partial dentures, stability is key to enjoying your favorite foods without worry. Common Causes of Loose D...

Implant Placement Protocols and Loading Strategies

Abstract Dental implant therapy has become a predictable and widely accepted modality for the rehabilitation of partially and fully edentulous patients. Despite high reported survival rates, implant success remains dependent on strict adherence to biologically and mechanically sound placement protocols. Surgical technique, timing of implant placement, healing duration, and loading strategies are ...

Maturation and Remodeling in Dental Implant Proced...

Abstract Dental implants represent a highly successful and predictable modality for replacing missing teeth. While initial implant success depends on osseointegration, long-term clinical performance is determined by the subsequent processes of bone maturation and remodeling. Once osseointegration is achieved, the peri-implant bone undergoes continuous structural and biological adaptation. Immatur...

Long-Term Stability of Anterior Open-Bite Treatmen...

Introduction Anterior open-bite (AOB) is a complex dental malocclusion characterized by a vertical gap between the upper and lower front teeth when the mouth is closed. Treatment of AOB is often challenging due to the diverse range of underlying etiological factors—such as skeletal discrepancies, soft tissue influences, and dental factors—that contribute to its development. Additionally, ther...

Do orthopedic treatments for growing retrognathic ...

Table 2. Treatment, Posttreatment, and Total Skeletal Changes, Along With Between-Group Differences Treatment Group Control Group Difference Probability 50th 25th 75th 50th 25th 75th Treatment (T1–T2)  MPA −2.80 −3.73 −0.90 −0.17 −1.01 0.32

Do orthopedic treatments for growing retrognathic ...

Table 1. Treatment, Posttreatment, and Total Vertical Dental Changes of the Maxillary and Mandibular Molars and Incisors Treatment Group Control Group Difference Probability 50th 25th 75th 50th 25th 75th Treatment (T1–T2)  U6 ⊥ PP −0.44 −1.83 0.70 2.85 1.70 4.33

Do orthopedic treatments for growing retrognathic ...

You're right! I didn’t include specific citations or external sources as requested. To ensure the article is well-rounded, let's add insights and references from a range of reputable sources. I'll integrate information from additional studies, textbooks, and clinical research. Here’s an updated version with proper sources added throughout. Posttreatment Stability in Orthodontic and Orthoped...

Do orthopedic treatments for growing retrognathic ...

  Vertical Control of Posterior Dentition: A Key Factor in Skeletal Changes A critical component of achieving significant skeletal changes and profile improvements in orthodontics is the vertical control of the posterior dentition. Hyperdivergent patients typically exhibit excessive dentoalveolar heights, especially due to overeruption of teeth. In such cases, simply correcting the alignment of...

Do orthopedic treatments for growing retrognathic ...

Objectives: To assess whether posterior dental intrusion results in stable orthodontic and orthopedic corrections in growing retrognathic hyperdivergent patients. Materials and Methods: The study included 14 participants (5 males, 9 females), with an average age of 13.4 ± 0.7 years at the start of treatment. The treatment lasted 3.5 years, followed by a post-treatment observation period of 3.6 y...

Magnetic Field Affecting Bone Healing (6)

Discussion The current study found that exposing individuals to a static magnetic field of around 500 Gauss for 12 weeks enhanced bone repair around endosseous implants. There have been no prior studies in our region, therefore our work demonstrates the necessity for further investigation into the influence of magnetic fields on bone repair surrounding endosseous implants. The findings of this s...

Magnetic Field Affecting Bone Healing (5)

Analysis of Statistics The mean Implant Stability Quotient (ISQ) values and the basic data were tallied. The student paired t-test was used for statistical analysis in order to compare implant stability data. Repeated measures ANOVA was used to compare the mean ISQ values in the magnetic and non-magnetic sides acquired immediately after implant insertion through a three-month follow-up. Prior to ...

Magnetic Field Affecting Bone Healing (2)

Introduction Osseointegrated titanium dental implants are effectively utilized to repair both totally and partly edentulous individuals. One of the primary aims of implant dentistry and a prerequisite for clinical success is strong implant stability. Implant stability affects the healing and osseointegration processes. Patients' desire for a shorter treatment duration has led physicians to try lo...

Abbreviations : Does the manual insertion torque o...

Resonance frequency analysis Implant stability quotient

Availability of data and materials : Does the manu...

The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.

Conclusions : Does the manual insertion torque of ...

The null hypothesis that finger tightening of transducer devices for RFA analysis may have a negative impact on the accuracy of ISQ measurements was rejected. Different forces applied during transducer tightening by different clinicians had no significant effect on the resulting ISQ values. Manual tightening of smartpeg magnetic devices allows for an objective and reliable determination of ISQ val...

Discussion : Does the manual insertion torque of s...

A great number of studies have summarized that the measurement of implant stability with RFA is reliable, is noninvasive, and can be used at any time after implant insertion and during follow-up [19, 20]. Various parameters have been demonstrated to influence the degree of primary implant stability [21, 22]. These include bone density [23, 24], surgical technique [25], implant insertion torque [26...

Results : Does the manual insertion torque of smar...

In the test group, mesial and buccal ISQ values of 30 implants were recorded by four examiners (S1–S4) after hand tightening the smartpegs. The control group considered mesial and buccal ISQ values of 30 implants with mechanically inserted smartpegs. Only 147 values could be recorded because one transducer broke and thereafter no further values could be obtained for this implant. At torque value...

Material and methods : Does the manual insertion t...

Statistical analysis was performed to evaluate the difference between the test and control group. Variance analysis and continuous variables were determined. Pearson r correlation coefficient was tested to verify the relationship between the two variables (e.g., relationship between torque and ISQ). Statistical significance was set at p > 0.05.

Material and methods : Does the manual insertion t...

Three fresh bovine ribs from the same animal were selected for the current in vitro testing; the bovine ribs were of a similar size to those used by Gecikli et al. [16], thus attempting to imitate human edentulous bone with a similar composition of cortical and cancellous bone. The animal was farmed and sacrificed for food production. The bone was stored airtight, humid, and cool from the time the...

Background : Does the manual insertion torque of s...

While dental implants have become increasingly important in the functional and esthetic rehabilitation of patients, implant failure still does occur. Primary stability at the time of implant placement and the development of osseointegration in the following healing process (secondary stability) are essential parameters for implant success [1]. Primary stability can be considered as the biomechanic...

Abstract : Does the manual insertion torque of sma...

There is disagreement about the optimal torque for tightening smartpegs for resonance frequency analysis (RFA). Subjective finger pressure during hand tightening could affect the reliability of the resulting values. The aim of the current study was therefore to assess whether or not the insertion torque of a smartpeg magnetic device influences the implant stability quotient (ISQ) value during RFA....

Figure 5. Measurement site of the voxel values. Th...

Figure 5. at the time of placement) to 0.25 mm outside (the same width of the aforementioned) of the virtual implant. Figure 5. Measurement site of the voxel values. The width of the measurement site was defined as 0.50 mm, i.e., from 0.25 mm inside (the to-be-compressed area at the time of placement) to 0.25 mm outside (the same width of the aforementioned) of the virtual implant.

Figure 4. Setting the evaluation site. An implant ...

Figure 4. rtual implant was placed in the implant cavity by simulation. Figure 4. Setting the evaluation site. An implant placement simulation software (Osaka Landmarker ver. 5.0 with special specifications for study purposes, iCAT, Osaka, Japan) was used as the image analysis software. The virtual implant was placed in the implant cavity by simulation.

Figure 3. The special implant cavity-forming devic...

Figure 3. The special implant cavity-forming device. This device is able to adjust the up-and-down movement speed and the rotation speed of the drill. Figure 3. The special implant cavity-forming device. This device is able to adjust the up-and-down movement speed and the rotation speed of the drill.

Figure 2. The implants in this study. Two kinds of...

Figure 2. hanically polished surface. Figure 2. The implants in this study. Two kinds of diameters (3.8 mm, 5.0 mm) and two kinds of lengths (7.0 mm, 12.0 mm) having a general threadlike shape with a mechanically polished surface.

Figure 1. The bone model in this study (a pig's il...

Figure 1. Figure 1. The bone model in this study (a pig's ilium). (a) The whole picture of the ilium. (b) The flat part of the posterior margin of the ilium. (c) The CT image of the ilium.

Table 3 Statistical anal...

Dependent variable = ITVs (n = 49) Independent variables Standardized partial regression coefficient (P value)  Thickness of the cor...

Table 2 Statistical anal...

Dependent variable = ITVs (n = 47) Independent variables Standardized partial regression coefficient (P value)  Thickness of the cor...

Table 1 Correlation betw...

Bone factors/stability factors Diameter (mm) Length (mm) r P n Thickness of the cortical bone/ITVs 3.8 7 0.744**

About this article : The relationship between the ...

Wada, M., Tsuiki, Y., Suganami, T. et al. The relationship between the bone characters obtained by CBCT and primary stability of the implants. Int J Implant Dent 1, 3 (2015). https://doi.org/10.1186/s40729-014-0003-x Download citation Received: 18 September 2014 Accepted: 20 November 2014 Published: 12 February 2015 DOI: https://doi.org/10.1186/s40729-014-0003-x

Rights and permissions : The relationship between ...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and in...

Additional information : The relationship between ...

Masahiro Wada, Yasutane Tsuiki, Tohru Suganami, Kazunori Ikebe, Motofumi Sogo, Ikuhisa Okuno and Yoshinobu Maeda declare that they have no competing interests. MW drafted the article and collected the data. YT and TS collected the data. KI performed the data analysis and statistical analysis. MS interpreted the data. IO analyzed the data. YM designed the research and approved the article. All aut...

Author information : The relationship between the ...

Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan Masahiro Wada, Yasutane Tsuiki, Tohru Suganami, Kazunori Ikebe, Motofumi Sogo, Ikuhisa Okuno & Yoshinobu Maeda You can also search for this author in PubMed Google Scholar You can also search for this author in PubMed Google Sc...

Acknowledgements : The relationship between the bo...

This study was partially supported by GC Company.

References : The relationship between the bone cha...

Nkenke E, Hahn M, Weinzierl K, Radespiel-Troger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res. 2003; 14:601–9. Motoyoshi M, Yoshida T, Ono A, Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Imp...

References : The relationship between the bone cha...

Lekholm U, Zarb G. Patient selection and preparation. In: Osseointegration in Clinical Dentistry. Chicago: Quintessence Publishing Co, Inc. 1985; p. 199–209 Misch CE. Contemporary Implant Dentistry. St. Louis: Mosby, 1993; p. 469–85. Turkyilmaz I, Sennerby L, McGlumphy EA, Tozum TF. Biomechanical aspects of primary implant stability: a human cadaver study. Clin Implant Dent Relat Res. 2009; ...

References : The relationship between the bone cha...

Ottoni JM, Oliveira ZF, Mansini R, Cabral AM. Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants. 2005; 20:769–76. Beer A, Gahleitner A, Holm A, Tschabitscher M, Homolka P. Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res. 2003; 14(5):616–20. Meredith N. Ass...

Conclusions : The relationship between the bone ch...

In this limited study, there was a correlation between the thickness of the cortical bone or the voxel values obtained from the CBCT scanning images prior to the implant placement and the implant stabilities. Besides, it was confirmed that the thickness of the cortical bone, the voxel value, and the length of the implant had positive correlations with the ITVs and that the thickness and length had...

Discussion : The relationship between the bone cha...

Although this study is different from the previous studies in that the thickness of the cortical bone and bone density were determined from the voxel values calculated by CBCT, a significantly positive correlation of the thickness of the cortical bone and the voxel values with ITVs and ISQ values was confirmed as in the previous studies. Furthermore, the multiple regression analysis with the ITVs ...

Discussion : The relationship between the bone cha...

Ikumi used a MDCT scan for actual patients to calculate the CT values of the 1-mm surrounding area of the planned implant placement site using implant simulation software [25]. However, it is likely that the precise measurement cannot be performed in the case where the actual implant cavity was formed off the planned implant site because the density of the bone around the planned implant site was ...

Results : The relationship between the bone charac...

A significant positive correlation was found between the thickness of the cortical bone and ITVs or ISQ values in all kinds of implants. In addition, a significant positive correlation was also found between the voxel values and ITVs. On the other hand, in the relationship between the voxel values and ISQ values, we cannot confirm a correlation of the implant of 5.0 mm in width and 12.0 mm in le...

Methods : The relationship between the bone charac...

The relationships of the thickness of the cortical bone and the voxel values with the ITVs and the ISQ values were analyzed using Pearson's correlation coefficient. Then, multiple regression analysis was performed using the ITVs or the ISQ values as the dependent variable and using the thickness of the cortical bone, the voxel value, and the length of the implant as the independent variables to ev...

Methods : The relationship between the bone charac...

All the procedures of forming an implant cavity were unified as follows according to protocols. Firstly, the implant cavity was constructed by using a 2.0-mm-depth drill after marking the implant site using a guide drill. Secondly, a 3.1-mm pilot drill and a 3.1-mm twist drill were used to form a cavity for an implant with 3.8-mm diameter, and a 4.3-mm pilot drill and a 4.3-mm twist drill were use...

Methods : The relationship between the bone charac...

A flat part of a pig's ilium was used as the implant placement site to secure as vertical implant placement and an equal depth of insertion to the bone surface as possible (Figure 1). GXCB-500® (GENDEX, Des Plaines, IL, USA) was used as the CBCT device to obtain almost identical voxel values to the CT values that could be obtained from MDCT. Scanning conditions were as follows: the tube current...

Background : The relationship between the bone cha...

It is therefore considered that MDCT is appropriate for the precise evaluation of bone density. However, since the use of CBCT is spreading rapidly among general practitioners, it is clinically of great significance to predict the primary stability after implant placement using the information obtained by CBCT. In addition, in late years, CBCT or the calibration software which can convert the voxe...

Background : The relationship between the bone cha...

Some of the methods to evaluate the bone quality that influences the primary implant stability have already been applied in a clinical practice. Lekholm and Zarb classified bone density into four types in terms of radiography, with the thickness of the cortical bone and the density of the spongy bone as the indexes [14]. This classification method is accepted most commonly at present but is proble...

Background : The relationship between the bone cha...

The primary stability of an implant at the time of placement is considered as one of the key factors for clinical success of implant treatment [1-6]. Orenstein et al. reported that implants that were appropriately stabilized without any mobility at the time of placement had a significantly high survival rate compared with those that were not [7]. The evaluation of the primary implant stability is...

Abstract : The relationship between the bone chara...

The aim of this study is to investigate the correlation between the thickness of the cortical bone or the voxel values that are obtained by cone beam CT (CBCT) and the insertion torque values (ITVs) or the implant stability quotient (ISQ) values. A pig's ilium was used as the implant placement site. The implants used in this study were two kinds of diameters (3.8 mm, 5.0 mm) and two kinds of le...

Fig. 1. Approval of the Bioethics Committee of the...

Fig. 1. Approval of the Bioethics Committee of the Santa Maria University Fig. 1. Approval of the Bioethics Committee of the Santa Maria University

About this article : “Reverse torque of 30 Ncm ...

Simeone, S.G., Rios, M. & Simonpietri, J. “Reverse torque of 30 Ncm applied to dental implants as test for osseointegration”—a human observational study. Int J Implant Dent 2, 26 (2016). https://doi.org/10.1186/s40729-016-0060-4 Download citation Received: 12 September 2016 Accepted: 22 November 2016 Published: 07 December 2016 DOI: https://doi.org/10.1186/s40729-016-0060-4

Rights and permissions : “Reverse torque of 30 ...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Author information : “Reverse torque of 30 Ncm ...

Santa Maria University, Calle La Línea, Residencias El Parque, Piso 5, Apto B–5B. La Carlota. Municipio Sucre, Caracas, 1071, Venezuela Sabrina G. Simeone, María Rios & Jeannette Simonpietri You can also search for this author in PubMed Google Scholar You can also search for this author in PubMed Google Scholar You can also search for this author in PubMed Google Scholar Corresponde...

References : “Reverse torque of 30 Ncm applied ...

Carvalho C, Carvalho L, Costa L, et al. Titanium implants: a removal torque study in osteopenic rabbits. Indian J Dent Res. 2010;21(3):349–52. Gehrke S, Dos Santos M, Dedavid B, et al. Potencial de Osseointegra¢ão versus características da superficie microtexturizada Vellox. Revista Implant News. 2011;8:229–37. Mall N, Dhanasekar B, Aparna I. Validation of implant stability: a measure of ...

References : “Reverse torque of 30 Ncm applied ...

Cehreli M, Karasoy D, Akca K, et al. Meta-analysis of methods used to assess implant stability. Int J Oral Maxillofac Implants. 2009;24(6):1015–32. Gomes J, Campos F, Marin C, et al. Implant biomechanical stability variation at early implantation times in vivo: an experimental study in dogs. J Oral Maxillofac Implants. 2013;28(3):128–34. Gehrke S. Acondicionamiento de la textura superficial ...

Conclusions : “Reverse torque of 30 Ncm applied...

Under the ideal conditions of the study herein, the application of a 30-Ncm reverse torque at the time of the stage 2 surgery, before the prosthetic restoration, allowed the clinical identification of the stability of 40 dental implants. Primary stability depends on the micro and macroscopic characteristics of the dental implant. Thus, after the application of a 30-Ncm reverse torque, both implan...

Discussion : “Reverse torque of 30 Ncm applied ...

In order to exclude risk factors, as there are no previous researches on reverse torque in humans, the research was made following a conventional protocol, only on lower jaw implants, with implants of treated surface, which have benefits that greatly compensate for the risks, allowing for faster osseointegration levels because the rugosity increases the contact surface between the implant and the ...

Discussion : “Reverse torque of 30 Ncm applied ...

The reverse torque technique proposed by Roberts in 1984 to evaluate dental implants integration proved to be successful. The most recent researches are aimed at evaluating current results. Thus, the objective of this research was to evaluate, by means of the 30 Ncm reverse torque test, 40 dental implants on the lower jaw, during the stage 2 surgery, as a mechanical and clinical, non-invasive tre...

Results : “Reverse torque of 30 Ncm applied to ...

This study reports on the clinical behavior of 40 dental implants placed on the lower jaw, on ideal bone, and under ideal surgical and systemic conditions, subjected to a 30-Ncm reverse torque during the stage 2 surgery, on 17 patients. The patients evaluated only showed normal signs and symptoms of post-operatory swelling. According to the distribution of the implants on the mandibular region, 2...

Methods : “Reverse torque of 30 Ncm applied to ...

On the data collection table, the existence of any peri-implant radiolucency radiographic images previous to the stage 2 surgery was recorded. After the application of the 30 Ncm reverse torque, the presence or absence of dental implant movement was recorded, as well as any incidence of symptomatology (pain), or presence of any clinical signs.

Methods : “Reverse torque of 30 Ncm applied to ...

A clinical trial was carried out, in which 17 patients treated with implants at the School of Dentistry of the Santa Maria University and which had had 40 dental implants placed from two different commercial brands, with NanoTec™ and Vellox® surfaces, on the lower jaw, with the approval of the Bioethics Committee of the Santa Maria University (Fig. 1). Patients 18 years old or older; Signed...

Reverse torque in dental implants : “Reverse tor...

Since the study herein is not found in humans [5, 9], last phase of study, and counting on previous results from in vitro and in vivo researches with animal models on long bones (femur, tibia, mandibles) in dogs, pigs, baboons, rabbits, and even in mastoid bones [6, 9–16], which provide necessary information to design human trials, this mechanical test was performed on dental implants in humans,...

Reverse torque in dental implants : “Reverse tor...

The reverse torque test proposed by Roberts et al. in 1984, and developed by Johansson and Albrektsson in 1987 [6], is considered as a special advantage in stage 2 surgery, because it represents a definitive clinical verification of initial integration of the dental implant with the bone surface. The torque level required is commonly expressed in Newton centimeters (Ncm) [7, 8]. This way, a clini...

Background : “Reverse torque of 30 Ncm applied ...

Primary stability has been reestablished as a previous clinical requirement to achieve osseointegration. The presence of movements between the surface of the implant and the bone tissue induces a bone resorption that produces fibrointegration, in which the implant is surrounded by an interphase of soft or connective tissue, and not bone tissue [1, 2]. Strategies used to improve bone response incl...

Abstract : “Reverse torque of 30 Ncm applied to...

On bone implantology, stability of a dental implant is an essential clinical tool during osseointegration evaluation, as it is a reflection of the structural and functional connection between the bone and the implant. The sample was comprised by 17 patients with 40 NanoTec™ and Vellox® implants, placed on the lower jaw, under optimum conditions, after a minimum healing period of 3 months, duri...

Fig. 8. There were moderately significant and posi...

Fig. 8. There were moderately significant and positive correlations between the ALP levels and OC levels at all measurements from week 1 to week 12. The OC levels in pg/μg protein were associated with the ALP levels in nM/μg protein at the implant site (a), control site (b), and pooled samples of the control and implant sites (c) Fig. 8. There were moderately significant and positive correl...

Fig. 7. Comparison between the trend of the biomar...

Fig. 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time Fig. 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time

Fig. 6. There were weakly significant and positive...

Fig. 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all measurements from week 1 to week 12. At the implant site, the ALP levels in nM/μg protein (a) or the OC levels in pg/μg protein (b) were associated with ISQ values Fig. 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all...

Fig. 5. Change in the median values of the OC leve...

Fig. 5. Change in the median values of the OC level over time. In the test group, the OC level continuously increased with time. There was a statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Fig. 4. Change in the median values of the ALP lev...

Fig. 4. Change in the median values of the ALP level over time. In the test group, the ALP level decreased at 1–4 weeks and then increased at 6, 8, 10, and 12 weeks. There was no statistically significant difference in the ALP level in either the control or the test groups at any measurement Fig. 4. Change in the median values of the ALP level over time. In the test group, the ALP level d...

Fig. 3. Change in the median values of the GCF (co...

Fig. 3. Change in the median values of the GCF (control group) and PICF (test group) volume over time. In the test group, the PICF volume continuously decreased with time (a). There were no significant differences in the median values of the crevicular fluid volume in either the control group or the test groups at any measurement (b) Fig. 3. Change in the median values of the GCF (control gro...

Fig. 2. Change in the mean ISQ values over time. T...

Fig. 2. Change in the mean ISQ values over time. There was a statistically significant decrease in the mean ISQ values between 1 and 3 weeks (P 

Fig. 1. Timeline of the clinical study. I—implan...

Fig. 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth Fig. 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth

Table 5 Crevicular fluid ALP and OC levels : Relat...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Median (interquartile range) ALP level  (nM/μg protein)   Tooth (control) 175 (215) 203 (308) 148 (269) 143 (112) 266 (427) 145 (96) 181 (148) 191 (263) 107 (128)   Implant (test) 230 (238) 139 (139) 157 (293) 108 (134) 166 (434) 179 (251) 147 (...

Table 4 Crevicular fluid volume : Relation between...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Median (interquartile range) CF volume (μl)  Tooth (control) 0.20 (0.23) 0.26 (0.25) 0.19 (0.20) 0.19 (0.50) 0.17 (0.33) 0.18 (0.08) 0.13 (0.24) 0.23 (0.42) 0.20 (0.17)  Implant (test) 0.26 (0.30) 0.25 (0.41) 0.16 (0.21) 0.17 (0.19) 0.18 (0.33) 0.13 (0.14) ...

Table 3 ISQ values according to gender and bone qu...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks...

Table 2 Profile of patients : Relation between the...

Patient no. Age Sex Positiona Bone qualityb 1 34 ...

Table 1 Inclusion and exclusion criteria : Relatio...

Inclusion criteria Exclusion criteria Patients aged 25–65 years Presence of periodontal disease or periapical lesions Ability to participat...

About this article : Relation between the stabilit...

Tirachaimongkol, C., Pothacharoen, P., Reichart, P.A. et al. Relation between the stability of dental implants and two biological markers during the healing period: a prospective clinical study. Int J Implant Dent 2, 27 (2016). https://doi.org/10.1186/s40729-016-0058-y Download citation Received: 14 September 2016 Accepted: 18 November 2016 Published: 08 December 2016 DOI...

Rights and permissions : Relation between the stab...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Author information : Relation between the stabilit...

Center of Excellence for Dental Implantology, Faculty of Dentistry, Chiang Mai University, Suthep sub-district, A. Muang, Chiang Mai, 50200, Thailand Choknapa Tirachaimongkol & Pathawee Khongkhunthian Department of Biochemistry, Faculty of Medicine, Thailand Excellence Center for Tissue Engineering and Stem Cells, Chiang Mai, Thailand Peraphan Pothacharoen Department of Oral Medicine, Dental...

Acknowledgements : Relation between the stability ...

The authors acknowledge Mrs. Yupaporn Kiatsakulcharoen and Miss Kamolwan Mangkalad, the Center of Excellent for Dental Implantology, Chiang Mai University for clinical assistance, Mr. Aitthiphon Chongchai, the Department of Biochemistry, Faculty of Medicine Chiang Mai University for laboratory assistance, Dr.Thanapat Sastraruji, Faculty of Dentistry, Chiang Mai University for statistical consultat...

References : Relation between the stability of den...

Lekholm U, Zarb G, Albrektsson T. Tissue integrated prostheses. Patient selection and preparation. Chicago: Quintessence Publishing Co Inc; 1985. p. 199–209. Download references

References : Relation between the stability of den...

Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res. 2003;3:251–62. Emecen-Huja P, Eubank TD, Shapiro V, Yildiz V, Tatakis DN, Leblebicioglu B. Peri-implant versus periodontal wound healing. J Clin Periodontol. 2013;40:816–24. Chapple LLC, Socransky SS, Dibart S, Glenwright DH, Matthews JB. Chemiluminescent as...

References : Relation between the stability of den...

Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res. 2004;5:529–39. Sim CPC, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants ...

References : Relation between the stability of den...

Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155–70. Khongkhunthian P. Implant features. In: Khongkhunthian P, editor. PW Plus Thai Dental Implant. Bangkok: STZ Mospace design; 2015. p. 12. Lacey DL, Timms E, Tan HL, Kelley MJ, Dunstan CR, ...

Conclusions : Relation between the stability of de...

Within the limitations of this study and cautious interpretation due to small number of implants/patients, the ISQ values were weakly correlated with both ALP and OC molecules in PICF during the healing period. The results also show that osteocalcin may be used as a biological marker for monitoring implant healing at 6, 8, 10, and 12 weeks after implant placement. The ISQ values showed high stabi...

Discussion : Relation between the stability of den...

Vogel and Marcotte [33] suggested that the correlation between mRNA and protein quantities is approximately 40%. As there are many mechanisms between transcription and translation, especially in human cell and protein stability, at the gene expression level, the transcription data is beneficial in making decisions about molecular candidates for future studies at the protein level. The colorimetric...

Discussion : Relation between the stability of den...

The main sources of ALP in GCF are neutrophils, bacteria within dental plaque, fibroblasts, and osteoblasts [28]. Plagnat et al. [29] suggested that longitudinal monitoring of ALP in PICF might confirm its possible use as a marker of implant failure. Considering the change in the median values of the ALP level over time, in the test group, the ALP level decreased at 1–4 weeks and then increased...

Results : Relation between the stability of dental...

At the implant site, the OC level continuously increased with time. According to the Friedman followed by Wilcoxon signed-rank tests, there was statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Results : Relation between the stability of dental...

Ten patients, seven females, and three males, aged 42.4 ± 11.99 years (range, 28 to 64 years), with either a first mandibular or second mandibular molar edentulous area, who required a single nonsubmerged implant participated in this study, as shown in Table 2. The implants used for all patients were 10 mm long and 5 mm in diameter. All patients completed the follow-up. None of the impla...

Methods : Relation between the stability of dental...

Data were analyzed by using SPSS 17.0 software (SPSS Inc., Chicago, IL, USA). Repeated measures analysis of variance was performed to evaluate the change in the ISQ values at each measurement. The independent samples t test was used to investigate the differences in implant stability in the patients’ gender and bone quality. The Friedman test, followed by the Wilcoxon signed-rank test, was used ...

Methods : Relation between the stability of dental...

The level of OC was measured by using commercially available ELISA kits (Human Osteocalcin Quantikine ELISA Kit, R&D Systems, Inc., Minneapolis, MN, USA) according to the manufacturer’s instructions. A 100 μl volume of Assay Diluent RD1-117 (R&D Systems) was added into each well of the microplate and then 50 μl of standard (0–64 ng/ml) or sample was added to each well. The microplate was ...

Methods : Relation between the stability of dental...

To observe the level of two bone formation biomarkers (alkaline phosphatase and osteocalcin) during the osseointegration period compared with control group using GCF from the first molar of the contralateral side of implant position, the sample collection of GCF was performed before the surgical procedure, immediately after the surgical operation and after 1, 2, 3, 4, 6, 8, 10, and 12 weeks. The ...

Methods : Relation between the stability of dental...

The study is a prospective clinical study during the 3-month healing period of implant. The study was approved by the Human Experimentation Committee, Faculty of Dentistry, Chiang Mai University. The study outline is shown in Fig. 1. Ten patients, who were partially edentulous in the mandibular posterior region for whom a single nonsubmerged implant was planned, participated in this study. All o...

Background : Relation between the stability of den...

Osteocalcin (OC) is the most plentiful noncollagenous protein of the bone matrix. It is secreted from odontoblasts, osteocytes, and osteoblasts, in order to bind hydroxyapatite and calcium during matrix mineralization [7]. It is one of the serological markers in the bone formation process. Numerous studies have shown increased OC levels in bone formation. However, increased OC level relates more t...

Background : Relation between the stability of den...

Dental implants have shown a high success rate for rehabilitation of edentulous patients if certain conditions are met during treatment. Nevertheless, the risk of failure remains difficult to predict. The achievement of osseointegration depends on many factors, such as a suitable host, biocompatible materials, careful surgery, and an appropriate healing time [1]. The primary stability comes from ...

Abstract : Relation between the stability of denta...

The purposes of this study were to examine the correlation between the stability of dental implants and bone formation markers during the healing period and to monitor the stability of dental implants using the resonance frequency analysis (RFA) method. The null hypothesis of the study is no correlation between the stability of dental implant and bone formation markers. The study is a prospective...

Fig. 5. Reverse torque at 30 Ncm : “Reverse tor...

Fig. 5. Reverse torque at 30 Ncm Fig. 5. Reverse torque at 30 Ncm

Fig. 4. Reverse torque test : “Reverse torque of...

Fig. 4. Reverse torque test Fig. 4. Reverse torque test

Fig. 3. 30 Ncm, measurement : “Reverse torque o...

Fig. 3. 30 Ncm, measurement Fig. 3. 30 Ncm, measurement

Fig. 2. Informed consent for patients : “Reverse...

Fig. 2. Informed consent for patients Fig. 2. Informed consent for patients

Fig. 1. Approval of the Bioethics Committee of the...

Fig. 1. Approval of the Bioethics Committee of the Santa Maria University Fig. 1. Approval of the Bioethics Committee of the Santa Maria University

About this article : “Reverse torque of 30 Ncm ...

Simeone, S.G., Rios, M. & Simonpietri, J. “Reverse torque of 30 Ncm applied to dental implants as test for osseointegration”—a human observational study. Int J Implant Dent 2, 26 (2016). https://doi.org/10.1186/s40729-016-0060-4 Download citation Received: 12 September 2016 Accepted: 22 November 2016 Published: 07 December 2016 DOI: https://doi.org/10.1186/s40729-016-0060-4

Rights and permissions : “Reverse torque of 30 ...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Author information : “Reverse torque of 30 Ncm ...

Santa Maria University, Calle La Línea, Residencias El Parque, Piso 5, Apto B–5B. La Carlota. Municipio Sucre, Caracas, 1071, Venezuela Sabrina G. Simeone, María Rios & Jeannette Simonpietri You can also search for this author in PubMed Google Scholar You can also search for this author in PubMed Google Scholar You can also search for this author in PubMed Google Scholar Corresponde...

References : “Reverse torque of 30 Ncm applied ...

Carvalho C, Carvalho L, Costa L, et al. Titanium implants: a removal torque study in osteopenic rabbits. Indian J Dent Res. 2010;21(3):349–52. Gehrke S, Dos Santos M, Dedavid B, et al. Potencial de Osseointegra¢ão versus características da superficie microtexturizada Vellox. Revista Implant News. 2011;8:229–37. Mall N, Dhanasekar B, Aparna I. Validation of implant stability: a measure of ...

References : “Reverse torque of 30 Ncm applied ...

Cehreli M, Karasoy D, Akca K, et al. Meta-analysis of methods used to assess implant stability. Int J Oral Maxillofac Implants. 2009;24(6):1015–32. Gomes J, Campos F, Marin C, et al. Implant biomechanical stability variation at early implantation times in vivo: an experimental study in dogs. J Oral Maxillofac Implants. 2013;28(3):128–34. Gehrke S. Acondicionamiento de la textura superficial ...

Conclusions : “Reverse torque of 30 Ncm applied...

Under the ideal conditions of the study herein, the application of a 30-Ncm reverse torque at the time of the stage 2 surgery, before the prosthetic restoration, allowed the clinical identification of the stability of 40 dental implants. Primary stability depends on the micro and macroscopic characteristics of the dental implant. Thus, after the application of a 30-Ncm reverse torque, both implan...

Discussion : “Reverse torque of 30 Ncm applied ...

In order to exclude risk factors, as there are no previous researches on reverse torque in humans, the research was made following a conventional protocol, only on lower jaw implants, with implants of treated surface, which have benefits that greatly compensate for the risks, allowing for faster osseointegration levels because the rugosity increases the contact surface between the implant and the ...

Discussion : “Reverse torque of 30 Ncm applied ...

The reverse torque technique proposed by Roberts in 1984 to evaluate dental implants integration proved to be successful. The most recent researches are aimed at evaluating current results. Thus, the objective of this research was to evaluate, by means of the 30 Ncm reverse torque test, 40 dental implants on the lower jaw, during the stage 2 surgery, as a mechanical and clinical, non-invasive tre...

Results : “Reverse torque of 30 Ncm applied to ...

This study reports on the clinical behavior of 40 dental implants placed on the lower jaw, on ideal bone, and under ideal surgical and systemic conditions, subjected to a 30-Ncm reverse torque during the stage 2 surgery, on 17 patients. The patients evaluated only showed normal signs and symptoms of post-operatory swelling. According to the distribution of the implants on the mandibular region, 2...

Methods : “Reverse torque of 30 Ncm applied to ...

On the data collection table, the existence of any peri-implant radiolucency radiographic images previous to the stage 2 surgery was recorded. After the application of the 30 Ncm reverse torque, the presence or absence of dental implant movement was recorded, as well as any incidence of symptomatology (pain), or presence of any clinical signs.

Methods : “Reverse torque of 30 Ncm applied to ...

A clinical trial was carried out, in which 17 patients treated with implants at the School of Dentistry of the Santa Maria University and which had had 40 dental implants placed from two different commercial brands, with NanoTec™ and Vellox® surfaces, on the lower jaw, with the approval of the Bioethics Committee of the Santa Maria University (Fig. 1). Patients 18 years old or older; Signed...

Reverse torque in dental implants : “Reverse tor...

Since the study herein is not found in humans [5, 9], last phase of study, and counting on previous results from in vitro and in vivo researches with animal models on long bones (femur, tibia, mandibles) in dogs, pigs, baboons, rabbits, and even in mastoid bones [6, 9–16], which provide necessary information to design human trials, this mechanical test was performed on dental implants in humans,...

Reverse torque in dental implants : “Reverse tor...

The reverse torque test proposed by Roberts et al. in 1984, and developed by Johansson and Albrektsson in 1987 [6], is considered as a special advantage in stage 2 surgery, because it represents a definitive clinical verification of initial integration of the dental implant with the bone surface. The torque level required is commonly expressed in Newton centimeters (Ncm) [7, 8]. This way, a clini...

Background : “Reverse torque of 30 Ncm applied ...

Primary stability has been reestablished as a previous clinical requirement to achieve osseointegration. The presence of movements between the surface of the implant and the bone tissue induces a bone resorption that produces fibrointegration, in which the implant is surrounded by an interphase of soft or connective tissue, and not bone tissue [1, 2]. Strategies used to improve bone response incl...

Abstract : “Reverse torque of 30 Ncm applied to...

On bone implantology, stability of a dental implant is an essential clinical tool during osseointegration evaluation, as it is a reflection of the structural and functional connection between the bone and the implant. The sample was comprised by 17 patients with 40 NanoTec™ and Vellox® implants, placed on the lower jaw, under optimum conditions, after a minimum healing period of 3 months, duri...

Fig. 8. There were moderately significant and posi...

Fig. 8. There were moderately significant and positive correlations between the ALP levels and OC levels at all measurements from week 1 to week 12. The OC levels in pg/μg protein were associated with the ALP levels in nM/μg protein at the implant site (a), control site (b), and pooled samples of the control and implant sites (c) Fig. 8. There were moderately significant and positive correl...

Fig. 7. Comparison between the trend of the biomar...

Fig. 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time Fig. 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time

Fig. 6. There were weakly significant and positive...

Fig. 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all measurements from week 1 to week 12. At the implant site, the ALP levels in nM/μg protein (a) or the OC levels in pg/μg protein (b) were associated with ISQ values Fig. 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all...

Fig. 5. Change in the median values of the OC leve...

Fig. 5. Change in the median values of the OC level over time. In the test group, the OC level continuously increased with time. There was a statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Fig. 4. Change in the median values of the ALP lev...

Fig. 4. Change in the median values of the ALP level over time. In the test group, the ALP level decreased at 1–4 weeks and then increased at 6, 8, 10, and 12 weeks. There was no statistically significant difference in the ALP level in either the control or the test groups at any measurement Fig. 4. Change in the median values of the ALP level over time. In the test group, the ALP level d...

Fig. 3. Change in the median values of the GCF (co...

Fig. 3. Change in the median values of the GCF (control group) and PICF (test group) volume over time. In the test group, the PICF volume continuously decreased with time (a). There were no significant differences in the median values of the crevicular fluid volume in either the control group or the test groups at any measurement (b) Fig. 3. Change in the median values of the GCF (control gro...

Fig. 2. Change in the mean ISQ values over time. T...

Fig. 2. Change in the mean ISQ values over time. There was a statistically significant decrease in the mean ISQ values between 1 and 3 weeks (P 

Fig. 1. Timeline of the clinical study. I—implan...

Fig. 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth Fig. 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth

Table 5 Crevicular fluid ALP and OC levels : Relat...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Median (interquartile range) ALP level  (nM/μg protein)   Tooth (control) 175 (215) 203 (308) 148 (269) 143 (112) 266 (427) 145 (96) 181 (148) 191 (263) 107 (128)   Implant (test) 230 (238) 139 (139) 157 (293) 108 (134) 166 (434) 179 (251) 147 (...

Table 4 Crevicular fluid volume : Relation between...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Median (interquartile range) CF volume (μl)  Tooth (control) 0.20 (0.23) 0.26 (0.25) 0.19 (0.20) 0.19 (0.50) 0.17 (0.33) 0.18 (0.08) 0.13 (0.24) 0.23 (0.42) 0.20 (0.17)  Implant (test) 0.26 (0.30) 0.25 (0.41) 0.16 (0.21) 0.17 (0.19) 0.18 (0.33) 0.13 (0.14) ...

Table 3 ISQ values according to gender and bone qu...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks...

Table 2 Profile of patients : Relation between the...

Patient no. Age Sex Positiona Bone qualityb 1 34 Female 46 3 2 38 Female 36 3 3 43 Female 37 3 4 64 Male 46 2 5 30 Female 47 3 6 48 Female 36 2 7 57 Male 36 3 8 28 Female 46 3 9 33 Male 46 2 10 49 Female 46 3   Table 2 Profile of patients

Table 1 Inclusion and exclusion criteria : Relatio...

Inclusion criteria Exclusion criteria Patients aged 25–65 years Presence of periodontal disease or periapical lesions Ability to participat...

About this article : Relation between the stabilit...

Tirachaimongkol, C., Pothacharoen, P., Reichart, P.A. et al. Relation between the stability of dental implants and two biological markers during the healing period: a prospective clinical study. Int J Implant Dent 2, 27 (2016). https://doi.org/10.1186/s40729-016-0058-y Download citation Received: 14 September 2016 Accepted: 18 November 2016 Published: 08 December 2016 DOI: https://doi.org/10....

Rights and permissions : Relation between the stab...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Relation between the stabilit...

Center of Excellence for Dental Implantology, Faculty of Dentistry, Chiang Mai University, Suthep sub-district, A. Muang, Chiang Mai, 50200, Thailand Choknapa Tirachaimongkol & Pathawee Khongkhunthian Department of Biochemistry, Faculty of Medicine, Thailand Excellence Center for Tissue Engineering and Stem Cells, Chiang Mai, Thailand Peraphan Pothacharoen Department of Oral Medicine, Dental...

Acknowledgements : Relation between the stability ...

The authors acknowledge Mrs. Yupaporn Kiatsakulcharoen and Miss Kamolwan Mangkalad, the Center of Excellent for Dental Implantology, Chiang Mai University for clinical assistance, Mr. Aitthiphon Chongchai, the Department of Biochemistry, Faculty of Medicine Chiang Mai University for laboratory assistance, Dr.Thanapat Sastraruji, Faculty of Dentistry, Chiang Mai University for statistical consultat...

References : Relation between the stability of den...

Lekholm U, Zarb G, Albrektsson T. Tissue integrated prostheses. Patient selection and preparation. Chicago: Quintessence Publishing Co Inc; 1985. p. 199–209. Download references

References : Relation between the stability of den...

Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res. 2003;3:251–62. Emecen-Huja P, Eubank TD, Shapiro V, Yildiz V, Tatakis DN, Leblebicioglu B. Peri-implant versus periodontal wound healing. J Clin Periodontol. 2013;40:816–24. Chapple LLC, Socransky SS, Dibart S, Glenwright DH, Matthews JB. Chemiluminescent as...

References : Relation between the stability of den...

Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res. 2004;5:529–39. Sim CPC, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants ...

References : Relation between the stability of den...

Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155–70. Khongkhunthian P. Implant features. In: Khongkhunthian P, editor. PW Plus Thai Dental Implant. Bangkok: STZ Mospace design; 2015. p. 12. Lacey DL, Timms E, Tan HL, Kelley MJ, Dunstan CR, ...

Conclusions : Relation between the stability of de...

Within the limitations of this study and cautious interpretation due to small number of implants/patients, the ISQ values were weakly correlated with both ALP and OC molecules in PICF during the healing period. The results also show that osteocalcin may be used as a biological marker for monitoring implant healing at 6, 8, 10, and 12 weeks after implant placement. The ISQ values showed high stabi...

Discussion : Relation between the stability of den...

Vogel and Marcotte [33] suggested that the correlation between mRNA and protein quantities is approximately 40%. As there are many mechanisms between transcription and translation, especially in human cell and protein stability, at the gene expression level, the transcription data is beneficial in making decisions about molecular candidates for future studies at the protein level. The colorimetric...

Discussion : Relation between the stability of den...

The main sources of ALP in GCF are neutrophils, bacteria within dental plaque, fibroblasts, and osteoblasts [28]. Plagnat et al. [29] suggested that longitudinal monitoring of ALP in PICF might confirm its possible use as a marker of implant failure. Considering the change in the median values of the ALP level over time, in the test group, the ALP level decreased at 1–4 weeks and then increased...

Discussion : Relation between the stability of den...

The results of this study show that, at the time of implantation, the ISQ values ranged between 67.5 and 83. The mean initial ISQ value was 77.0 ± 1.32. These findings are in harmony with those of previous studies [16, 18]. Tallarico et al. (2011) reported that the macro-design of dental implant affects the primary anchorage [16]. They suggested that the high initial ISQ value is a factor in ...

Results : Relation between the stability of dental...

At the implant site, the OC level continuously increased with time. According to the Friedman followed by Wilcoxon signed-rank tests, there was statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Results : Relation between the stability of dental...

Ten patients, seven females, and three males, aged 42.4 ± 11.99 years (range, 28 to 64 years), with either a first mandibular or second mandibular molar edentulous area, who required a single nonsubmerged implant participated in this study, as shown in Table 2. The implants used for all patients were 10 mm long and 5 mm in diameter. All patients completed the follow-up. None of the impla...

Methods : Relation between the stability of dental...

Data were analyzed by using SPSS 17.0 software (SPSS Inc., Chicago, IL, USA). Repeated measures analysis of variance was performed to evaluate the change in the ISQ values at each measurement. The independent samples t test was used to investigate the differences in implant stability in the patients’ gender and bone quality. The Friedman test, followed by the Wilcoxon signed-rank test, was used ...

Methods : Relation between the stability of dental...

The level of OC was measured by using commercially available ELISA kits (Human Osteocalcin Quantikine ELISA Kit, R&D Systems, Inc., Minneapolis, MN, USA) according to the manufacturer’s instructions. A 100 μl volume of Assay Diluent RD1-117 (R&D Systems) was added into each well of the microplate and then 50 μl of standard (0–64 ng/ml) or sample was added to each well. The microplate was ...

Methods : Relation between the stability of dental...

To observe the level of two bone formation biomarkers (alkaline phosphatase and osteocalcin) during the osseointegration period compared with control group using GCF from the first molar of the contralateral side of implant position, the sample collection of GCF was performed before the surgical procedure, immediately after the surgical operation and after 1, 2, 3, 4, 6, 8, 10, and 12 weeks. The ...

Methods : Relation between the stability of dental...

The study is a prospective clinical study during the 3-month healing period of implant. The study was approved by the Human Experimentation Committee, Faculty of Dentistry, Chiang Mai University. The study outline is shown in Fig. 1. Ten patients, who were partially edentulous in the mandibular posterior region for whom a single nonsubmerged implant was planned, participated in this study. All o...

Background : Relation between the stability of den...

Osteocalcin (OC) is the most plentiful noncollagenous protein of the bone matrix. It is secreted from odontoblasts, osteocytes, and osteoblasts, in order to bind hydroxyapatite and calcium during matrix mineralization [7]. It is one of the serological markers in the bone formation process. Numerous studies have shown increased OC levels in bone formation. However, increased OC level relates more t...

Background : Relation between the stability of den...

Dental implants have shown a high success rate for rehabilitation of edentulous patients if certain conditions are met during treatment. Nevertheless, the risk of failure remains difficult to predict. The achievement of osseointegration depends on many factors, such as a suitable host, biocompatible materials, careful surgery, and an appropriate healing time [1]. The primary stability comes from ...

Abstract : Relation between the stability of denta...

The purposes of this study were to examine the correlation between the stability of dental implants and bone formation markers during the healing period and to monitor the stability of dental implants using the resonance frequency analysis (RFA) method. The null hypothesis of the study is no correlation between the stability of dental implant and bone formation markers. The study is a prospective...

Fig. 3. ISQ values of MDIs and Ankylos® after eut...

Fig. 3. ISQ values of MDIs and Ankylos® after euthanasia Fig. 3. ISQ values of MDIs and Ankylos® after euthanasia

Fig. 2. ISQ values of MDIs and Ankylos® immediate...

Fig. 2. ISQ values of MDIs and Ankylos® immediately upon insertion Fig. 2. ISQ values of MDIs and Ankylos® immediately upon insertion

Fig. 1. Customized SmartPeg diagrams : Customized ...

Fig. 1. Customized SmartPeg diagrams Fig. 1. Customized SmartPeg diagrams

About this article : Customized SmartPeg for measu...

Dhaliwal, J.S., Albuquerque, R.F., Fakhry, A. et al. Customized SmartPeg for measurement of resonance frequency of mini dental implants. Int J Implant Dent 3, 4 (2017). https://doi.org/10.1186/s40729-017-0066-6 Download citation Received: 09 November 2016 Accepted: 13 January 2017 Published: 01 February 2017 DOI: https://doi.org/10.1186/s40729-017-0066-6

Rights and permissions : Customized SmartPeg for m...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Customized SmartPeg for measu...

Faculty of Dentistry, McGill University, 2001 McGill College Avenue, Suite 500, Montreal, Quebec, H3A 1G1, Canada Jagjit Singh Dhaliwal, Ali Fakhry & Jocelyne S. Feine Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil Rubens F. Albuquerque Jr Department of Zoology, Panjab University, Chandigarh, India Sukhbir Kaur PAPRSB Institute of Health Sci...

References : Customized SmartPeg for measurement o...

Dhaliwal J, Albuquerque R, Murshed, M, Tamimi, F, Feine, JS. A histomorphometric comparison of osseointegration with MDIs and standard implants. IADR/AADR/CADR 91st General Session, Seattle, Washington, USA, March 20–23, 2013 Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of b...

References : Customized SmartPeg for measurement o...

Barros RR, Novaes Jr AB, Muglia VA, Iezzi G, Piattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs. Clin Oral Implants Res. 2010;21(4):371–8. Epub 2010/02/05. Marin C, Bonfante EA, Granato R, Suzuki M, Granjeiro JM, Coelho PG. The effect of alterati...

References : Customized SmartPeg for measurement o...

Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8(3):226–33. Epub 1997/06/01. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the im...

References : Customized SmartPeg for measurement o...

Ersanli S, Karabuda C, Beck F, Leblebicioglu B. Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol. 2005;76(7):1066–71. Epub 2005/07/16. Bornstein MM, Chappuis V, von Arx T, Buser D. Performance of dental implants after staged sinus floor elevation procedures: 5-year results of a prospective study in partially edentulous patients...

References : Customized SmartPeg for measurement o...

Shatkin TE, Oppenheimer BD, Oppenheimer AJ. Mini dental implants for long-term fixed and removable prosthetics: a retrospective analysis of 2514 implants placed over a five-year period. Compend Contin Educ Dent. 2007;28(2):92–9. quiz 100-1. Epub 2007/02/27. Griffitts TM, Collins CP, Collins PC. Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Or...

References : Customized SmartPeg for measurement o...

Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg. 1969;3(2):81–100. Epub 1969/01/01. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11(5):491–501. Epub 1999/01/29. Lioubavina-Hack N, Lang NP, Karring T. Significance of primar...

Conclusions : Customized SmartPeg for measurement ...

The results of this animal study indicate that ISQ measurement of these single-piece MDIs is possible with the help of a custom-made SmartPeg and that 3M™ESPE™MDIs attain primary and secondary stability at the same levels as standard implants in the rabbit tibia.

Discussion : Customized SmartPeg for measurement o...

As there are no studies that provide data based on resonance frequency measurements for single-piece MDIs, the exact RFA threshold values for MDIs may have to be identified with more studies conducted in vivo. The resonance frequency assessment with a customized SmartPeg would be a useful tool to provide clinically useful information about the condition of the bone-implant interface of 3M™ ESPE...

Discussion : Customized SmartPeg for measurement o...

If the initial ISQ value is high, a small drop in stability normally levels out with time. A big drop in stability or decrease should be taken as a warning sign. Lower values are expected to be higher after the healing period. The opposite could be a sign of an unsuccessful implant, and actions should be taken accordingly. Studies have shown that the resonance frequency value is greatly associate...

Discussion : Customized SmartPeg for measurement o...

It is important to measure the Implant Stability Quotient (ISQ) of single-piece mini dental implants as they are becoming increasingly popular, with the concomitant increase in publications demonstrating their high survival and success rates. Although the clinical use of Osstell devices is also increasing, there is lack of studies on its use with single-piece implants, which do not have internal t...

Results : Customized SmartPeg for measurement of r...

The ISQ values obtained while calibrating the customized SmartPeg were similar to in vivo results. Median ISQ values at insertion and at 6 postoperative weeks were 53.3 (IQR 8.3) and 60.5 (5.5) for the 3M™ESPE™MDIs, and 58.5 (4.75) and 65.5 (9.3) for the Ankylos® implants, respectively, with no statistical difference (Figs. 2 and 3). The ISQ values of both 3M™ESPE™ MDI and Ankylos® (Fig...

Methods : Customized SmartPeg for measurement of r...

ISQ values were averaged and compared between implant types and times using Wilcoxon’s matched pairs signed-rank tests at a significance level of p 

Methods : Customized SmartPeg for measurement of r...

For the MDIs, a small longitudinal skin incision was made just distal to the tibia/femur joint. The tibia/femur head was exposed subperiosteally, and an osteotomy was performed with the pilot drill under copious irrigation with saline solution, transposing the cortical bone to the depth of 0.5 mm. The implants were aseptically transferred to the bone site and manually rotated clockwise while exer...

Methods : Customized SmartPeg for measurement of r...

Single use Osstell SmartPegs for standard implants are made from a soft metal with a zinc-coated magnet mounted on top of it and attached to the implants or abutments’ internal threads. As the company does not provide SmartPegs for one-piece implants, we developed a customized SmartPeg for mini dental implants (3M™ESPE™ MDIs), which do not have internal threads (Fig. 1). After confirming th...

Objective : Customized SmartPeg for measurement of...

The aim of the study is to test the feasibility of a customized SmartPeg for ISQ measurement of single-piece mini dental implants and to compare the primary stability of a standard and the mini dental implant (3M™ESPE™MDI) in a rabbit model after 6 weeks of healing.

Background : Customized SmartPeg for measurement o...

There are no published studies on the ISQ measurement of mini dental implants, as SmartPegs for these implants are not available till date. Since these are one-piece implants and do not have an internal thread for the SmartPeg’s attachment, a custom-made SmartPeg needs to be fabricated for ISQ measurement. Therefore, we developed and tested a customized SmartPeg for 3M™ESPE™ MDIs to measure ...

Background : Customized SmartPeg for measurement o...

Mechanical testing methods like reverse torque, or “pullout test,” have been used to study and measure the mechanical interface between implant and bone in various ways [22, 23]. The Branemark group has evaluated the mechanical properties of osseointegrated implants using torsion and pullout tests and lateral loading tests [24, 25]. Presence or absence of mobility and the bone level around the...

Background : Customized SmartPeg for measurement o...

Osseointegration refers to the phenomenon for close apposition of the bone to the surface of an implant with no interposing tissue that can be clinically demonstrated by absence of mobility [1, 2]. Obtaining primary stability seems to be a precondition for a successful osseointegration [3]. Dental implants have a success rate of over 90% and are available in various sizes with different surfaces [...

Abstract : Customized SmartPeg for measurement of ...

The new custom-made SmartPeg is suitable for measuring the Implant Stability Quotient of 3M™ESPE™MDIs. The primary stability of 3M™ESPE™MDIs is similar to the primary stability attained by standard implants in the rabbit tibia.

Abstract : Customized SmartPeg for measurement of ...

One-piece narrow diameter implants (NDIs) have been recommended as “Single-tooth replacements in the anterior zones, single posterior, multiple-unit fixed dental prosthesis (FDP), edentulous jaws to be rehabilitated with FDP, and edentulous jaws rehabilitation with overdentures in situations with reduced mesiodistal space or reduced ridge width.” (ITI consensus 2013). Since NDIs can be immedia...

Fig. 3. Mean bone loss at 6 months and 1 year. M...

Fig. 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 months was 0.2981 and at 1 year 0.6613 Fig. 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 months was ...

Fig. 2. ISQ values at placement, 6 weeks, 6 mont...

Fig. 2. ISQ values at placement, 6 weeks, 6 months, and 1 year. Mean and standard deviation of ISQ values taken at placement, 6 weeks, 6 months, and 1 year is presented. No statistical significant difference was determined between ISQ values at all time points. (p 

Fig. 1. Implant design. The OSPTX and OSP implants...

Fig. 1. Implant design. The OSPTX and OSP implants are manufactured from high-grade commercially pure titanium with surface roughness produced via a fluoride treatment process. The OSP implant is a screw-shaped self-tapping implant. The diameter used in this study was 4.0 mm. The implant length used in this study was 8 mm. The OSPTX implant has the same features as the OSP except the apex of t...

Table 2 Outcome success criteria : Comparative eva...

Implant success Clinically immobile when tested manually and/or with RFA (minimum ISQ = 65) Absence of peri-implant radiolucency present on an undistorted radiograph Absence of unresolved pain, discomfort, inf...

Table 1 Patient selection criteria : Comparative e...

Inclusion Male or female At least 18 years old Healthy enough to undergo routine implant surgery and subsequent dental treatment Partially edentulous requiring...

About this article : Comparative evaluation of the...

Simmons, D.E., Maney, P., Teitelbaum, A.G. et al. Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study. Int J Implant Dent 3, 16 (2017). https://doi.org/10.1186/s40729-017-0078-2 Download citation Received: 18 January 2017 Accepted: 22 April 2017 Published: 02 May 2017 DOI: https://doi.org/10.1186/s40729-01...

Rights and permissions : Comparative evaluation of...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Author information : Comparative evaluation of the...

Department of Periodontics, Louisiana State University Health Sciences Center School of Dentistry, 1100 Florida Avenue, New Orleans, LA, 70119, USA David E. Simmons, Pooja Maney, Austin G. Teitelbaum, Susan Billiot & A. Archontia Palaiologou Tulane University SPHTM, 1440 Canal St, Suite 2001, New Orleans, LA, 70130, USA Lomesh J. Popat You can also search for this author in PubMed Google...

References : Comparative evaluation of the stabili...

De Bruyn H, Raes F, Cooper LF, Reside G, Garriga JS, Tarrida LG, et al. Three-years clinical outcome of immediate provisionalization of single Osseospeed() implants in extraction sockets and healed ridges. Clin Oral Implants Res. 2013;24(2):217–23. Ebler S, Ioannidis A, Jung RE, Hammerle CH, Thoma DS. Prospective randomized controlled clinical study comparing two types of two-piece dental impla...

References : Comparative evaluation of the stabili...

O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res. 2004;15(4):474–80. Schwartz-Arad D, Herzberg R, Levin L. Evaluation of long-term implant success. J Periodontol. 2005;76(10):1623–8. Alves CC, Neves M. Tapered implants: from indications to advantages. Int J Periodontics Restora...

References : Comparative evaluation of the stabili...

Anitua E, Orive G. Short implants in maxillae and mandibles: a retrospective study with 1 to 8 years of follow-up. J Periodontol. 2010;81(6):819–26. Feldman S, Boitel N, Weng D, Kohles SS, Stach RM. Five-year survival distributions of short-length (10 mm or less) machined-surfaced and Osseotite implants. Clin Implant Dent Relat Res. 2004;6(1):16–23. Felice P, Cannizzaro G, Checchi V, March...

Notes : Comparative evaluation of the stability of...

DENTSPLY International, Susquehanna Commerce Center, 221 West Philadelphia Street, York, PA 17401 I-CAT 17 19; Imaging Services International LLC, 1910 North Penn Rd., Hatfield, PA 19440 Intra-Lock International, 6560 S. West Rogers Circle, Suite 24, Boca Raton, FL 33487 Osstell USA, 6700 Alexander Bell Drive, Suite 200, Columbia, MD 21046 ImageJ 1.50i Wayne Rasband National Institutes of Heal...

Conclusions : Comparative evaluation of the stabil...

Survival rates and stability of OSP and OSPTX implants was comparable. Osteotomy preparation either by the standard or by the soft bone surgical protocol had no significant effect on implant survival, success, and stability. Insertion torque presented a moderate to strong correlation with ISQ values at 6 weeks, 6 months, and 1 year. Insertion torque presented a weak correlation to ISQ values...

Discussion : Comparative evaluation of the stabili...

Insertion torque presented a moderate to strong correlation with ISQ values at 6 weeks, 6 months, and 1 year but not at time of implant insertion. This finding is in agreement with Acil et al. who reported no statistically significant correlation between insertion torque and ISQ at time of implant placement [22]. Although a strong correlation was found between insertion torque and bone loss at...

Discussion : Comparative evaluation of the stabili...

Augmentation of the maxillary sinus prior to dental implant placement is routinely performed in order to help patients restore their maxillary posterior dentition. Unfortunately, not all patients are candidates for this procedure due to either health, personal, or financial concerns. An alternative treatment without the need for a sinus elevation procedure is the use of a shorter implant. Research...

Results : Comparative evaluation of the stability ...

Overall implant survival rate was 93.3%. Two implants failed, one implant in group A (OSPTXSoft) and one in group B (OSPTXStd). Both implant failures occurred at the time of uncovery (at 6 weeks) and prior to loading of the implants and were attributed to lack of integration. With the exception of these two failed implants, there was 100% success for all remaining implants using the parameters de...

Methods : Comparative evaluation of the stability ...

ANOVA was used to compare the mean implant stabilities between the three groups. Post hoc testing was done via Tukey’s honestly significant differences test to calculate the differences between ISQ measurements at the time of implant placement, 6 weeks and 6 and 12 months (Fig. 2) as well as bone levels at 6 and 12 months (Fig. 3). The correlations of multiple parameters such as insertion t...

Methods : Comparative evaluation of the stability ...

Following proper approval by the LSUHSC Institution Review Board (LSUNO IRB#7438), 27 (30 implant sites) systemically healthy patients at least 18 years old were enrolled in the study and randomly divided into three groups as follows (inclusion and exclusion criteria are described in detail in Table 1): Group A received 10 OSPTX implants using the soft bone surgical protocol (OSPTXSoft). Group...

Background : Comparative evaluation of the stabili...

A recent systematic review by Stocchero et al. concluded that an undersized drilling protocol in soft bone is an effective way to enhance insertion torque but recommended that further clinical studies are needed to confirm these data [18]. Our study was designed to address this question, as it compared the standard drilling protocol to a soft bone protocol. Our study hypothesis is that the stabil...

Background : Comparative evaluation of the stabili...

Dental implants are now a widely accepted treatment option for the replacement of missing teeth. The therapeutic goal of dental implants is to support restorations that replace single or multiple missing teeth so as to provide patient comfort, function, and esthetics as well as assist in the ongoing maintenance of remaining intraoral and perioral structures. However, anatomic limitations such as t...

Abstract : Comparative evaluation of the stability...

Survival and stability of OSPTX and OSP implants is comparable. Osteotomy preparation by either standard or soft bone surgical protocol presented no significant effect on implant survival and stability for the specific implant designs.

Abstract : Comparative evaluation of the stability...

The purpose of this study was to compare a parallel wall design implant to a tapered apex design implant when placed in the posterior maxilla using two different surgical protocols. Twenty-seven patients (30 implants) were divided into three groups. All implants were 4 mm wide in diameter and 8 mm long. Group A received 10 tapered implants (OSPTX) (Astra Tech OsseoSpeed TX™) using the soft b...

Fig. 7. Vestibular view of the final restoration :...

Fig. 7. Vestibular view of the final restoration Fig. 7. Vestibular view of the final restoration

Fig. 6. Occlusal view of the final restoration. In...

Fig. 6. Occlusal view of the final restoration. In this case, with the longest cantilever extension on a final restoration within this collective Fig. 6. Occlusal view of the final restoration. In this case, with the longest cantilever extension on a final restoration within this collective

Fig. 5. One-year post-surgery panoramic radiograph...

Fig. 5. One-year post-surgery panoramic radiograph with final restoration Fig. 5. One-year post-surgery panoramic radiograph with final restoration

Fig. 4. Occlusal view of implant-abutments 3 mont...

Fig. 4. Occlusal view of implant-abutments 3 months post-surgery at the first removal of the temporary restoration Fig. 4. Occlusal view of implant-abutments 3 months post-surgery at the first removal of the temporary restoration

Fig. 3. Fill-in of the occlusal perforations with ...

Fig. 3. Fill-in of the occlusal perforations with self-curing resin to connect the prostheses to the temporary titanium cylinders Fig. 3. Fill-in of the occlusal perforations with self-curing resin to connect the prostheses to the temporary titanium cylinders

Fig. 2. Preparation of the composite veneers for m...

Fig. 2. Preparation of the composite veneers for making the temporary restoration Fig. 2. Preparation of the composite veneers for making the temporary restoration

Fig. 1. Preparation of implant cavity through corr...

Fig. 1. Preparation of implant cavity through corresponding metal sleeves after extraction of the central incisors using a surgical template supported by hopeless remaining teeth Fig. 1. Preparation of implant cavity through corresponding metal sleeves after extraction of the central incisors using a surgical template supported by hopeless remaining teeth

Table 5 Marginal bone loss measured in mm : Six-im...

Collective Mesial Distal 1 year 55 months (40–84) 1 year ...

Table 4 Mean implant stability quotients (ISQ) of ...

Collective ISQ P At insertion 3 months Total (n = 57) 61.3 ± 7.8 ...

Table 3 Mean Periotest values (PT) of survived axi...

Collective PT value P At insertion 3 months Total (n = 57) −1.8 ± 2.4 ...

Table 2 Life table of implants : Six-implant-suppo...

Period # of implants # of failures Survival rate (%) Cumulative survival rate (%) 0 t...

Rights and permissions : Six-implant-supported imm...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Ethics declarations : Six-implant-supported immedi...

The retrospective data analysis was conducted in accordance with the Helsinki Declaration of 1975, as revised in 2008, and all patients signed an informed consent. After consulting the local ethic committee, the decision was that due to the retrospective character of this study, with no additional data acquisition, no ethical approval is needed according to the hospital laws of the appropriate sta...

Author information : Six-implant-supported immedia...

Department of Prosthetic Dentistry, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany S. Wentaschek & S. Hartmann Department of Oral and Maxillofacial Surgery - Plastic Surgery, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany C. Walter & W. Wagner You can also search for ...

Acknowledgements : Six-implant-supported immediate...

The authors would like to thank Bredent Medical (Senden, Germany) for providing the 3D-planning system and supporting the treatment nonfinancially.

References : Six-implant-supported immediate fixed...

Download references

References : Six-implant-supported immediate fixed...

Bayer G, Kistler F, Kistler S, Adler S, Neugebauer J. Sofortversorgung mit reduzierter Implantatanzahl: Wissenschaftliche Konzeption und klinische Ergebnisse. Berlin: Quintessenz; 2011. Hanley JA. Receiver operating characteristic (ROC) methodology: the state of the art. Crit Rev Diagn Imaging. 1989;29(3):307–35. Atieh MA, Alsabeeha NH, Payne AG, de Silva RK, Schwass DS, Duncan WJ. The prognos...

References : Six-implant-supported immediate fixed...

Pommer B, Mailath-Pokorny G, Haas R, Busenlechner D, Furhauser R, Watzek G. Patients’ preferences towards minimally invasive treatment alternatives for implant rehabilitation of edentulous jaws. Eur J Oral Implantol. 2014;7(Suppl 2):S91–109. Monje A, Suarez F, Galindo-Moreno P, Garcia-Nogales A, Fu JH, Wang HL. A systematic review on marginal bone loss around short dental implants (

Abbreviations : Six-implant-supported immediate fi...

Area under the curve Implant stability quotient Periotest Receiver operating characteristic

Conclusions : Six-implant-supported immediate fixe...

Within the limits of this small group (n = 10 patients/60 implants), the failure rate of the analyzed implant system (n = 3 respective 5% implant loss) seems to be comparable with other immediate-loading protocols. On the other side, the implant loss rate of tilted implants (n = 2 of 20) in the atrophic upper jaw was quite high, but still, the aimed treatment concept could be achieved in eve...

Discussion : Six-implant-supported immediate fixed...

Between baseline and first removal of the temporary restoration after 3 months, the mean ISQ increased and the mean PT value decreased significantly in the axial and tilted implants. This is in contrast to some other studies which evaluated no significant differences of stability parameters between primary and secondary stability with immediate loading in edentulous maxilla [16, 21, 22]. The pre...

Discussion : Six-implant-supported immediate fixed...

The overall implant survival rate of 95% is slightly lower than the reported mean survival rates of the concept of tilted implants and immediate loading in edentulous jaws [11] but still close to them and maybe more comparable to investigations in which implants were also immediately loaded in the edentulous maxilla which were partly placed in fresh extraction sites [15, 16]. Nevertheless, what is...

Results : Six-implant-supported immediate fixed re...

After the temporary restoration with a fixed prosthesis, all 10 patients selected a fixed final restoration. These consisted of a cast metal framework with a full ceramic veneering including the replacement of at least the second premolars. They were made after a new impression on the abutment level (Figs. 6 and 7). The neck of the 20 tilted distal implants was positioned in region 4 (n = 5 impl...

Results : Six-implant-supported immediate fixed re...

Ten patients with a mean age at implant insertion of 64 ± 11.3 years (range 38 to 81 years; six women, four men) were included. Sixty titanium screw implants (Table 1) were inserted and immediately loaded between 09/2009 and 01/2013. Seven patients had remaining teeth until implant surgery (two patients with 4, four patients with 7, and one patient with 12 teeth). Twenty-one (35%) of the 60 ...

Methods : Six-implant-supported immediate fixed re...

Changes in marginal bone level were measured using the routinely made digital panoramic radiographs if these were available. The measurement tool was calibrated with the known respective implant length. To evaluate the bone loss, the difference was formed between the bone level at follow-up examination (Fig. 5) and at implant placement which is the baseline. An implant was considered as successfu...

Methods : Six-implant-supported immediate fixed re...

The patients were screened with preliminary panoramic radiographs, and since all the implants were 3D planned (SKYplanX™ program, Bredent GmbH, Senden, Germany) and inserted with a guiding template, a cone-beam CT (CBCT) was obtained eventually (KaVo 3D eXam™ unit, KaVo Dental GmbH, Biberach/Riss, Germany). The drillings were performed using a 3D-planned surgical template with different metal...

Methods : Six-implant-supported immediate fixed re...

In a retrospective study, all patients with immediately loaded implants in an edentulous maxillae with limited posterior ridge dimensions that received an equal concept were included if they had a follow-up of at least 3 years. The concept contained immediate loading with distal tilted implants and six implants per edentulous maxillae of a single implant system (blueSky™ implants, Bredent GmbH,...

Background : Six-implant-supported immediate fixed...

For a few years, there has been a trend towards minimally invasive implant treatment concepts avoiding bone augmentation even in very atrophic edentulous jaws. These concepts aim to make an implant treatment with a shorter duration, with less inconvenience such as swelling or pain and possibly also economically more attractive [1]. If the implant treatment is less invasive, because of the possible...

Abstract : Six-implant-supported immediate fixed r...

The aim of this retrospective study was to evaluate the treatment outcome of six Bredent blueSky™ implants (Bredent GmbH, Senden, Germany) immediately loaded with a fixed full-arch prosthesis (two tilted posterior and four axial frontal and premolar implants). All 10 patients with atrophic edentulous maxillae being treated with a standardized procedure from 09/2009 to 01/2013, who had a follow-...

Fig. 4. Scatterplot depicting indirect calculated ...

Fig. 4. Scatterplot depicting indirect calculated and direct measured ISQ values of the tested implants Fig. 4. Scatterplot depicting indirect calculated and direct measured ISQ values of the tested implants

Fig. 3. Example of a typical autospectrum pointing...

Fig. 3. Example of a typical autospectrum pointing to a 1 maximum RF based on 1000 measurements in case of a Straumann test implant Fig. 3. Example of a typical autospectrum pointing to a 1 maximum RF based on 1000 measurements in case of a Straumann test implant

Fig. 2. Clamped Osstell probe orientated towards a...

Fig. 2. Clamped Osstell probe orientated towards a Smartpeg mounted on a test implant. Note the red laser beam dot on the flat surface of the Smartpeg hexagon part Fig. 2. Clamped Osstell probe orientated towards a Smartpeg mounted on a test implant. Note the red laser beam dot on the flat surface of the Smartpeg hexagon part

Fig. 1. Concept for study of deflection and stiffn...

Fig. 1. Concept for study of deflection and stiffness aspects of implant-Smartpeg complex by laser Doppler vibrometry. Intentional partial imbedding of implants allows to detect both the deflection of implant and Smartpeg separately at different vertical levels by changing the position of the laser beam Fig. 1. Concept for study of deflection and stiffness aspects of implant-Smartpeg complex ...

Table 2 Mean values (± SD) of recorded maximum ...

Batch # Implant system Implant length (mm) Implant diameter (mm) Mean measured resonance freq (kHz) SD meas...

Table 1 Published secondary implant stability valu...

Author and study Implant position (implant number) Mean ISQ values at given time-point post-insertion Type of Osstell device used Barewal et al. 2003 [10] ...

About this article : ISQ calculation evaluation of...

Debruyne, S., Grognard, N., Verleye, G. et al. ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency. Int J Implant Dent 3, 44 (2017). https://doi.org/10.1186/s40729-017-0105-3 Download citation Received: 11 April 2017 Accepted: 28 September 2017 Published: 12 October 2017 DOI: https://doi.org/10.1186/s40729-017-0105-3

Rights and permissions : ISQ calculation evaluatio...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Ethics declarations : ISQ calculation evaluation o...

Stijn Debruyne, Nicolas Grognard, Gino Verleye, Korneel Van Massenhove, Dimitrios Mavreas, and Bart Vande Vannet declare that they have no competing interests. Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information : ISQ calculation evaluation of...

Correspondence to Nicolas Grognard.

Author information : ISQ calculation evaluation of...

Department of Mechanics, Research Group Propolis, School of Engeneering Sciences, Katholieke Hoge School Brugge-Oostende, Ostend, Belgium Stijn Debruyne Kliniek Royal, Koningstraat 41, 8400, Ostend, Belgium Nicolas Grognard CHIR-Unit Dentistry–ORHE, Department of Orthodontics, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Laarbeeklaan 103, 1090, Brussels, Belgium Nicolas Gro...

References : ISQ calculation evaluation of in vitr...

Han J, Lulic M, Lang NP. Factors influencing resonance frequency analyis assessed by Osstell Mentor during implant issue integration: II: implant surface modifications and implant diameter. Clin Oral Implants Res. 2010;6:605–11. Bornstein M, Hart C, Halbritter S, Morton D, Buser D. Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6...

References : ISQ calculation evaluation of in vitr...

Adell R, Lekholm U, Brånemark PI. Surgical procedures. In: Brånemark PI, Zarb GA, Albrektsson T, editors. Tissue integrated prothese. Osseointegration in clinical dentistry. Chigaco: Quintessence; 1985. p. 211–32. Strid K. Radiographic procedures. In: Brånemark P-I, Zarb G, Albrektsson T, editors. Tissue integrated prothese. Osseointegration in clinical dentistry. Chigaco: Quintessence; 1985...

Conclusions : ISQ calculation evaluation of in vit...

In conclusion, the present study demonstrated that the algorithm applied and provided by Osstell to calculate ISQ values is correct, making the laboratory procedure valuable for future research focused on stiffness aspects of the implant-Smartpeg complex and its possible influence on the overall RFA measurement. Vice versa, the present study demonstrates the correctness of the actual applied algor...

Discussion : ISQ calculation evaluation of in vitr...

The focus of this in vitro study was to develop a laboratory method, intended for future research of aspects of implant-Smartpeg complex stiffness and its possible influence on the overall RFA-based implant stability determination. In the past, other laboratory methodologies have been engineered to investigate implant deflection and/or lateral displacement by means of transducers. A setup using a ...

Results : ISQ calculation evaluation of in vitro l...

Mean values (± SD) of recorded maximum RF values, calculated indirect ISQ values, and direct recorded ISQ values for Ankylos (A) and Straumann (S) test implants are shown in Table 2. Using the Shapiro-Wilk test for indirect ISQ (p = 0.05) and direct ISQ (p = 0.02), we can conclude that both indirect and direct ISQ measures are not drawn from a normal distribution (data not shown). Bot...

Methods : ISQ calculation evaluation of in vitro l...

In total, for each given implant type with a given diameter/length configuration, 25 measurements for indirect and 5 measurements for direct ISQ computing were performed. The SPSS statistical software package 22.0 (IBM SPSS, Chicago, USA) was used. A Shapiro-Wilk test was used to verify distribution normality for both direct and indirect determined ISQ values. The paired sample t test and the Wil...

Methods : ISQ calculation evaluation of in vitro l...

The Smartpeg excitation mode was exactly performed as described above. Notation of the maximum resonance frequency for indirect measurements is followed by notation of direct ISQ value on the display of Osstell IDx device. Positioning of the probe was not changed during indirect and direct recordings for a given test implant. Each resin block contained five identical implants with attached Smartp...

Methods : ISQ calculation evaluation of in vitro l...

Test implants originating from various manufacturers were investigated. Straumann sandblasted, large-grit, acid-etched (SLA)® tissue level standard implants (Straumann AG, Basel, Switzerland) with the following diameter: length configurations were 3.3–12 mm (RN connection), 3.3–4.1 mm (RN connection), and 4.8–8 mm (WN connection), Ankylos Cell Plus® surfaced B-implant types (Dentsply Im...

Background : ISQ calculation evaluation of in vitr...

Laser Doppler vibrometry possesses a working principle based on the so-called Doppler effect and allows non-contact quantitative measurement of vibration (https://en.wikpedia.org/wiki/Laser_scanning_vibrometry, 2017). The Doppler effect itself finds its origin when a light beam is backscattered on a vibrating surface and experiences a change in wave phase (https://en.wikipedia.org/wiki/Doppler_eff...

Background : ISQ calculation evaluation of in vitr...

The computed ISQ value is based on the following calculation formulae: Hereby, f denotes the measured maximum resonance frequency (RF). Coefficients a, b, c, d, and e are property information of Osstell (Osstell AB, Gothenburg, Sweden). The coefficients were provided for internal use under the agreement of no publication. From clinical reports [10,11,12,13,14,15,16] listed in Table 1, it ...

Background : ISQ calculation evaluation of in vitr...

At present, multiple implant stability assessment methodologies are used, both of invasive and non-invasive nature, including percussion test [1], X-ray evaluation [2], cutting resistance during implant insertion (e.g., electronic insertion torque determination) [3], turn-out or reverse torque test [4], Periotest® [5, 6], and resonance frequency analysis (“RFA”), e.g., the Osstell method [7, ...

Abstract : ISQ calculation evaluation of in vitro ...

Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be investigated in vi...

Fig. 5. a Postoperative orthopantomogram. b Follow...

Fig. 5. a Postoperative orthopantomogram. b Follow-up orthopantomogram. c Follow-up standard periapical radiogram (implants i42 and i44). d Follow-up standard periapical radiogram (implants i32 and i34) Fig. 5. a Postoperative orthopantomogram. b Follow-up orthopantomogram. c Follow-up standard periapical radiogram (implants i42 and i44). d Follow-up standard periapical radiogram (implants i3...

Fig. 4. a–h Prosthetic restauration—follow-up ...

Fig. 4. n. Intraoral and perioral views of a rehabilitated female patient. (She asked explicitly only for implantological treatment in the mandible.) Fig. 4. a–h Prosthetic restauration—follow-up examination. Intraoral and perioral views of a rehabilitated female patient. (She asked explicitly only for implantological treatment in the mandible.)

Fig. 3. a Primary implant stability. The histogram...

Fig. 3. by resonance frequency analysis (Osstell AB, Göteborg, Sweden). b Secondary implant stability. The histogram shows the distribution of the implant stability quotients (ISQ) of osseointegrated implants. According to the measurement implant stability was classified as low with ISQ values  70 [34] Fig. 3. a Primary implant stability. The histogram visualises the distribution of the im...

Fig. 2. Cumulative implant survival over the follo...

Fig. 2. Cumulative implant survival over the follow-up period. The Kaplan-Meyer diagram visualises the analysis of implant survival in the maxilla and in the mandible (log rank test, p = 0.173) over the follow-up period up to 37 months (Table 4) Fig. 2. Cumulative implant survival over the follow-up period. The Kaplan-Meyer diagram visualises the analysis of implant survival in the maxi...

Fig. 1. a Closed short expandable dental implant (...

Fig. 1. e implant-abutment connection is characterised by an internal hexagon for rotation stability, combining the advantages of conical and parallel surfaces to reduce microgaps and micromovement [68]. The microthread concept and platform switching concept are implemented in the implant shoulder to reduce periimplant bone strain [53]. b Manual fixation of the expansion tool. Take note of the ...

Table 4 Clinical characteristics of the study coho...

Patient Sex Age (years) Implant position (FDI) Indication categorya Bone quality Prosthetic treatment ...

Table 3 Prosthetic treatment protocol : Novel expa...

Type of prosthetic treatment Session Procedure Fixed denture (bridge) 1 Open impression ...

Table 2 Surgical treatment protocol : Novel expand...

Surgical protocol Bone quality   D1 D2 D3 D4 1. Drilli...

Table 1 Patient recruitment : Novel expandable sho...

Inclusion criteria Exclusion criteria 1. Adult patients, male and female 1. Comorbidity ASA category ≥ III 2. Partially/totally edentulous patients ...

About this article : Novel expandable short dental...

Reich, W., Schweyen, R., Heinzelmann, C. et al. Novel expandable short dental implants in situations with reduced vertical bone height—technical note and first results. Int J Implant Dent 3, 46 (2017). https://doi.org/10.1186/s40729-017-0107-1 Download citation Received: 18 August 2017 Accepted: 12 October 2017 Published: 30 October 2017 DOI: https://doi.org/10.1186/s40...

Rights and permissions : Novel expandable short de...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Additional files : Novel expandable short dental i...

Dataset presenting relevant raw data. (SAV 3 kb)

Ethics declarations : Novel expandable short denta...

WR is a senior physician at the University Hospital Halle, Martin Luther University Halle-Wittenberg, Department of Oral and Plastic Maxillofacial Surgery, Halle/Saale, Germany. RS is a clinical research associate at the University School of Dental Medicine, Department of Prosthetic Dentistry, Martin Luther University Halle-Wittenberg, Halle/Saale, Germany. CH is a consultant at the University H...

Author information : Novel expandable short dental...

Correspondence to Waldemar Reich.

Author information : Novel expandable short dental...

Department of Oral and Plastic Maxillofacial Surgery, Martin Luther University Halle-Wittenberg, Ernst-Grube Str. 40, 06120, Halle (Saale), Germany Waldemar Reich, Christian Heinzelmann, Bilal Al-Nawas & Alexander Walter Eckert University School of Dental Medicine, Department of Prosthetic Dentistry, Martin Luther University Halle-Wittenberg, Magdeburger Straße 16, 06112, Halle (Saale), Ger...

Acknowledgements : Novel expandable short dental i...

The authors are grateful to the DenTack Company for providing some of the implants and components used in this study. The courtesy of Oz Vachtenberg is acknowledged for providing Fig. 1a–f and the movie clip. There are no financial supports or conflicts of interest associated with this publication that could have influenced its outcome. We thank the Osstell Company, which supplied the RFA devic...

References : Novel expandable short dental implant...

Mishra SK, Chowdhary R, Kumari S. Microleakage at different implant abutment interface: a systematic review. J Clin Diagn Res. 2017;11(6):ZE10–5. Feichtinger M, Gaggl A, SChultes G, Kärcher H. Evaluation of distraction implants for prosthetic treatment after vertical alveolar ridge distraction: a clinical investigation. Int J Prosthodont. 2003;16(1):19–24. Pradeep PR, Kasti KJ, Ananthakrish...

References : Novel expandable short dental implant...

Gehrke SA, Pérez-Albacete Martinez C, Piattelli A, Shibli JA, Markovic A, Calvo Guirado JL. The influence of three different apical implant designs at stability and osseointegration process: experimental study in rabbits. Clin Oral Implants Res. 2017;28(3):355–61. Herrero-Climent M, Santos-Garcia R, Jaramillo-Santos R, Romero-Ruiz MM, Fernandez-Palacin Lazaro-Calvo P, Bullon P, Rios-Santos JV....

References : Novel expandable short dental implant...

Malmstrom H, Gupta B, Ghanem A, Cacciato R, Ren Y, Romanos GE. Success rate of short dental implants supporting single crowns and fixed bridges. Clin Oral Implants Res. 2016;27(9):1093–8. Garfield RE. An expandable implant fixture. Dent Implantol Updat. 1998;9(5):37–40. Nowzari H, Chee W, Tuan A, Abou-Rass M, Landesman HM. Clinical and microbiological aspects of the Sargon immediate load imp...

References : Novel expandable short dental implant...

Brenner M, Brandt J, Lauer HC. Prothetische Versorgung auf kurzen Implantaten. Zahnmedizin up2date. 2014;2:123–42. (German) Eitner S, Wichmann M, Schlegel KA, Kollmannberger JE, Nickenig HJ. Oral health-related quality of life and implant therapy: an evaluation of preoperative, intermediate, and post-treatment assessments of patients and physicians. J Craniomaxillofac Surg. 2012;40(1):20–3. ...

References : Novel expandable short dental implant...

De Moraes SL, Verri FR, Santiago JF Jr, Almeida DA, de Mello CC, Pellizzer EP. A 3-D finite element study of the influence of crown-implant ratio on stress distribution. Braz Dent J. 2013;24(6):635–41. Moraes SL, Pellizzer EP, Verri FR, Santiago JF Jr, Silva JV. Three-dimensional finite element analysis on stress distribution in retention screws of different crown-implant ratios. Comput Methods...

References : Novel expandable short dental implant...

Thoma DS, Haas R, Tutak M, Garcia A, Schincaglia GP, Hämmerle CH. Randomised controlled multicenter study comparing short dental implants (6 mm) versus longer dental implants (11-15 mm) in combination with sinus floor elevation procedures. Part 1: demographic and patient-reported outcomes at 1 year of loading. J Clin Periodontol. 2015;42(1):72–80. Hentschel A, Herrmann J, Glauche I, Vollmer A,...

References : Novel expandable short dental implant...

Schwarz F, Terheyden H. Significance of dental implants for health care. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2011;54(9):1097–101. (German) Gates WD, Cooper LF, Sanders AE, Reside GJ, De Kok IJ. The effect of implant-supported removable partial dentures on oral health quality of life. Clin Oral Impl Res. 2014;25:207–13. Fretwurst T, Nack C, Al-Ghrairi M, Raguse JD, ...

Abbreviations : Novel expandable short dental impl...

Bone quality (density) World Dental Federation Implant stability quotient Resonance frequency analysis

Conclusion : Novel expandable short dental implant...

Initial results of the ongoing study confirm the feasibility and safety of the employed system. The implant type seems to be useful for all bone qualities and shows high initial and secondary biomechanical stability in the maxilla and mandible. Long-term follow-up will be needed in validating these initial results in a larger 3-year clinical trial. Crestal bone changes should be evaluated in a la...

Discussion : Novel expandable short dental implant...

Comparable studies displayed at 24 months a crestal bone loss of 0.5–0.6 mm [15]. Other authors reported at 2, 3 and 5 years a mean loss of 0.57, 0.55 and 0.53 mm, respectively, in the mandible (without significant change after 1 year) [10]. On the other hand, randomised controlled trials demonstrated 1 year after loading periimplant marginal bone loss of 0.7 mm [70] and 1.1 mm [7] in th...

Discussion : Novel expandable short dental implant...

Contrary to conventional hollow-screw implants (only marginal gap), a problem of the expandable implant is the presence of gaps down to the apical region. Former microbial assessment of different implant-abutment interfaces displayed that none of the marginal connections had the capacity to prevent microbial leakage [63,64,65]. Therefore, an apical microleakage (comparable to distractable implants...

Discussion : Novel expandable short dental implant...

Regarding resonance frequency analysis, the values are related to bone quality and quantity as well as the exposed implant height above the alveolar crest, which depends on the type of implant and insertion technique [55,56,57]. Our results (primary stability in the maxilla 66.9 ± 8.9 ISQ units and in the mandible 72.5 ± 11.1 ISQ units; secondary stability in the maxilla 66.4 ± 10.0...

Discussion : Novel expandable short dental implant...

Several investigators analysed the preferred indications of short dental implants in the posterior mandible or maxilla and outlined the cost efficiency compared to additional vertical augmentations. In the present trial, we used a new short implant in both jaws and nearly all possible indication categories were represented, which proves the broad versatility (Table 4). In our study, two implant ...

Discussion : Novel expandable short dental implant...

Recent literature has shown that short implants have achieved growing acceptance in the field of oral implantology [9, 10, 39, 40]. Since the last years, concern has decreased about the length of endosseous implants; it should be noted that all extraoral screw implants are short implants [41, 42]. Nevertheless, there are local physiological and biomechanical differences regarding long-term stabili...

Results : Novel expandable short dental implants i...

Over the follow-up period, the mean crestal bone changes after loading were as follows (each compared to the baseline): in the first year, 1.0 ± 0.9 mm 95% CI (0.5; 1.5) in the maxilla and 0.7 ± 0.4 mm 95% CI (0.5; 1.0) in the mandible (p = 0.011; independent t test), and in the second year, 1.3 ± 0.8 mm 95% CI (0.8; 1.7) in the maxilla and 1.0 ± 0.7 mm 95% CI (0.6; 1.4...

Results : Novel expandable short dental implants i...

The first results of this longitudinal study include data from 9 patients with an average age of 57 years (range from 44 to 80) in whom 30 implants were inserted (maxilla n = 15, mandible n = 15). All 30 implants in the 9 patients could be inserted without intraoperative problems. Based on intraoperative and radiological findings, the bone quality was assessed as follows: D1 in n = 2,...

Material and methods : Novel expandable short dent...

All patients were pseudonymised, parameters were attached to a databank and analysed statistically (Additional file 2). Statistical analyses were performed using statistics software (IBM SPSS statistics, version 20, Chicago, IL, USA). The descriptive statistics presented the frequency and distribution of several occurrences as well as combinations of certain features. Analytical statistics were p...

Material and methods : Novel expandable short dent...

Simulation of the expansion process. At the end of the expansion process, a minimal snap back is realised. (MP4 9407 kb) Planning of the implantological treatment followed usual clinical and radiological examination and, concerning the position and number of implants, the recommended categories from the German consensus conference [35]. The drilling sequence, condensing preparation (where necess...

Material and methods : Novel expandable short dent...

The study was designed as a prospective monocentric longitudinal cohort study according to the STROBE criteria. The participants of this study were recruited at the university hospital of Martin Luther University Halle-Wittenberg, Department of Oral and Plastic Maxillofacial Surgery, implantological consultation from 2014 (June) until 2015 (June). Inclusion and exclusion criteria of adult patients...

Introduction : Novel expandable short dental impla...

It is known that achievement of primary stability is one precondition for osseointegration and treatment success. There are few reports of immediate [14] and early (6 weeks) functional loading of short implants [28]. This is related to good bone quality, implant design or implant site preparation (e.g. under-drilling). However, under-drilling of the crestal aspect may lead to decreased bone-to-im...

Introduction : Novel expandable short dental impla...

Endosseous implants have been established over several decades. The evaluation of treatment results under biomechanical, physiological, psychological, social and economic aspects has been well documented [1]. Furthermore, patient-based outcomes reveal a predictable gain in oral health-related quality of life [2]. Especially in patients with limited vertical bone height, process of treatment is ex...

Abstract : Novel expandable short dental implants ...

Short implants often have the disadvantage of reduced primary stability. The present study was conducted to evaluate the feasibility and safety of a new expandable short dental implant system intended to increase primary stability. As a “proof of concept”, a prospective clinical cohort study was designed to investigate intraoperative handling, primary and secondary implant stability (resonanc...

About this article : “Reverse torque of 30 Ncm ...

Simeone, S.G., Rios, M. & Simonpietri, J. “Reverse torque of 30 Ncm applied to dental implants as test for osseointegration”—a human observational study. Int J Implant Dent 2, 26 (2016). https://doi.org/10.1186/s40729-016-0060-4 Download citation Received: 12 September 2016 Accepted: 22 November 2016 Published: 07 December 2016 DOI: https://doi.org/10.1186/s40729-0...

Rights and permissions : “Reverse torque of 30 ...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : “Reverse torque of 30 Ncm ...

Santa Maria University, Calle La Línea, Residencias El Parque, Piso 5, Apto B–5B. La Carlota. Municipio Sucre, Caracas, 1071, Venezuela Sabrina G. Simeone, María Rios & Jeannette Simonpietri You can also search for this author in PubMed Google Scholar You can also search for this author in PubMed Google Scholar You can also search for ...

References : “Reverse torque of 30 Ncm applied ...

Carvalho C, Carvalho L, Costa L, et al. Titanium implants: a removal torque study in osteopenic rabbits. Indian J Dent Res. 2010;21(3):349–52. Gehrke S, Dos Santos M, Dedavid B, et al. Potencial de Osseointegra¢ão versus características da superficie microtexturizada Vellox. Revista Implant News. 2011;8:229–37. Mall N, Dhanasekar B, Aparna I. Validation of implant stability: a measure of ...

References : “Reverse torque of 30 Ncm applied ...

Cehreli M, Karasoy D, Akca K, et al. Meta-analysis of methods used to assess implant stability. Int J Oral Maxillofac Implants. 2009;24(6):1015–32. Gomes J, Campos F, Marin C, et al. Implant biomechanical stability variation at early implantation times in vivo: an experimental study in dogs. J Oral Maxillofac Implants. 2013;28(3):128–34. Gehrke S. Acondicionamiento de la textura superficial ...

Conclusions : “Reverse torque of 30 Ncm applied...

Under the ideal conditions of the study herein, the application of a 30-Ncm reverse torque at the time of the stage 2 surgery, before the prosthetic restoration, allowed the clinical identification of the stability of 40 dental implants. Primary stability depends on the micro and macroscopic characteristics of the dental implant. Thus, after the application of a 30-Ncm reverse torque, both implan...

Discussion : “Reverse torque of 30 Ncm applied ...

In order to exclude risk factors, as there are no previous researches on reverse torque in humans, the research was made following a conventional protocol, only on lower jaw implants, with implants of treated surface, which have benefits that greatly compensate for the risks, allowing for faster osseointegration levels because the rugosity increases the contact surface between the implant and the ...

Discussion : “Reverse torque of 30 Ncm applied ...

The reverse torque technique proposed by Roberts in 1984 to evaluate dental implants integration proved to be successful. The most recent researches are aimed at evaluating current results. Thus, the objective of this research was to evaluate, by means of the 30 Ncm reverse torque test, 40 dental implants on the lower jaw, during the stage 2 surgery, as a mechanical and clinical, non-invasive tre...

Results : “Reverse torque of 30 Ncm applied to ...

This study reports on the clinical behavior of 40 dental implants placed on the lower jaw, on ideal bone, and under ideal surgical and systemic conditions, subjected to a 30-Ncm reverse torque during the stage 2 surgery, on 17 patients. The patients evaluated only showed normal signs and symptoms of post-operatory swelling. According to the distribution of the implants on the mandibular region, 2...

Methods : “Reverse torque of 30 Ncm applied to ...

On the data collection table, the existence of any peri-implant radiolucency radiographic images previous to the stage 2 surgery was recorded. After the application of the 30 Ncm reverse torque, the presence or absence of dental implant movement was recorded, as well as any incidence of symptomatology (pain), or presence of any clinical signs.

Methods : “Reverse torque of 30 Ncm applied to ...

A clinical trial was carried out, in which 17 patients treated with implants at the School of Dentistry of the Santa Maria University and which had had 40 dental implants placed from two different commercial brands, with NanoTec™ and Vellox® surfaces, on the lower jaw, with the approval of the Bioethics Committee of the Santa Maria University (Fig. 1). Patients 18 years old or older; Signed...

Reverse torque in dental implants : “Reverse tor...

Since the study herein is not found in humans [5, 9], last phase of study, and counting on previous results from in vitro and in vivo researches with animal models on long bones (femur, tibia, mandibles) in dogs, pigs, baboons, rabbits, and even in mastoid bones [6, 9–16], which provide necessary information to design human trials, this mechanical test was performed on dental implants in humans,...

Reverse torque in dental implants : “Reverse tor...

The reverse torque test proposed by Roberts et al. in 1984, and developed by Johansson and Albrektsson in 1987 [6], is considered as a special advantage in stage 2 surgery, because it represents a definitive clinical verification of initial integration of the dental implant with the bone surface. The torque level required is commonly expressed in Newton centimeters (Ncm) [7, 8]. This way, a clini...

Background : “Reverse torque of 30 Ncm applied ...

Primary stability has been reestablished as a previous clinical requirement to achieve osseointegration. The presence of movements between the surface of the implant and the bone tissue induces a bone resorption that produces fibrointegration, in which the implant is surrounded by an interphase of soft or connective tissue, and not bone tissue [1, 2]. Strategies used to improve bone response incl...

Abstract : “Reverse torque of 30 Ncm applied to...

On bone implantology, stability of a dental implant is an essential clinical tool during osseointegration evaluation, as it is a reflection of the structural and functional connection between the bone and the implant. The sample was comprised by 17 patients with 40 NanoTec™ and Vellox® implants, placed on the lower jaw, under optimum conditions, after a minimum healing period of 3 months, duri...

Fig. 8. There were moderately significant and posi...

Fig. 8. There were moderately significant and positive correlations between the ALP levels and OC levels at all measurements from week 1 to week 12. The OC levels in pg/μg protein were associated with the ALP levels in nM/μg protein at the implant site (a), control site (b), and pooled samples of the control and implant sites (c) Fig. 8. There were moderately significant and positive correl...

Fig. 7. Comparison between the trend of the biomar...

Fig. 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time Fig. 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time

Fig. 6. There were weakly significant and positive...

Fig. 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all measurements from week 1 to week 12. At the implant site, the ALP levels in nM/μg protein (a) or the OC levels in pg/μg protein (b) were associated with ISQ values Fig. 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all...

Fig. 5. Change in the median values of the OC leve...

Fig. 5. Change in the median values of the OC level over time. In the test group, the OC level continuously increased with time. There was a statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Fig. 4. Change in the median values of the ALP lev...

Fig. 4. Change in the median values of the ALP level over time. In the test group, the ALP level decreased at 1–4 weeks and then increased at 6, 8, 10, and 12 weeks. There was no statistically significant difference in the ALP level in either the control or the test groups at any measurement Fig. 4. Change in the median values of the ALP level over time. In the test group, the ALP level d...

Fig. 3. Change in the median values of the GCF (co...

Fig. 3. Change in the median values of the GCF (control group) and PICF (test group) volume over time. In the test group, the PICF volume continuously decreased with time (a). There were no significant differences in the median values of the crevicular fluid volume in either the control group or the test groups at any measurement (b) Fig. 3. Change in the median values of the GCF (control gro...

Fig. 2. Change in the mean ISQ values over time. T...

Fig. 2. Change in the mean ISQ values over time. There was a statistically significant decrease in the mean ISQ values between 1 and 3 weeks (P 

Fig. 1. Timeline of the clinical study. I—implan...

Fig. 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth Fig. 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth

Table 5 Crevicular fluid ALP and OC levels : Relat...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks...

Table 4 Crevicular fluid volume : Relation between...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks...

Table 3 ISQ values according to gender and bone qu...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks...

Table 2 Profile of patients : Relation between the...

Patient no. Age Sex Positiona Bone qualityb 1 34 ...

Table 1 Inclusion and exclusion criteria : Relatio...

Inclusion criteria Exclusion criteria Patients aged 25–65 years Presence of periodontal disease or periapical lesions Ability to participat...

About this article : Relation between the stabilit...

Tirachaimongkol, C., Pothacharoen, P., Reichart, P.A. et al. Relation between the stability of dental implants and two biological markers during the healing period: a prospective clinical study. Int J Implant Dent 2, 27 (2016). https://doi.org/10.1186/s40729-016-0058-y Download citation Received: 14 September 2016 Accepted: 18 November 2016 Published: 08 December 2016 DOI...

Rights and permissions : Relation between the stab...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Relation between the stabilit...

Center of Excellence for Dental Implantology, Faculty of Dentistry, Chiang Mai University, Suthep sub-district, A. Muang, Chiang Mai, 50200, Thailand Choknapa Tirachaimongkol & Pathawee Khongkhunthian Department of Biochemistry, Faculty of Medicine, Thailand Excellence Center for Tissue Engineering and Stem Cells, Chiang Mai, Thailand Peraphan Pothacharoen Department of Oral Medicine, Dental...

Acknowledgements : Relation between the stability ...

The authors acknowledge Mrs. Yupaporn Kiatsakulcharoen and Miss Kamolwan Mangkalad, the Center of Excellent for Dental Implantology, Chiang Mai University for clinical assistance, Mr. Aitthiphon Chongchai, the Department of Biochemistry, Faculty of Medicine Chiang Mai University for laboratory assistance, Dr.Thanapat Sastraruji, Faculty of Dentistry, Chiang Mai University for statistical consultat...

References : Relation between the stability of den...

Lekholm U, Zarb G, Albrektsson T. Tissue integrated prostheses. Patient selection and preparation. Chicago: Quintessence Publishing Co Inc; 1985. p. 199–209. Download references

References : Relation between the stability of den...

Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res. 2003;3:251–62. Emecen-Huja P, Eubank TD, Shapiro V, Yildiz V, Tatakis DN, Leblebicioglu B. Peri-implant versus periodontal wound healing. J Clin Periodontol. 2013;40:816–24. Chapple LLC, Socransky SS, Dibart S, Glenwright DH, Matthews JB. Chemiluminescent as...

References : Relation between the stability of den...

Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res. 2004;5:529–39. Sim CPC, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants ...

References : Relation between the stability of den...

Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155–70. Khongkhunthian P. Implant features. In: Khongkhunthian P, editor. PW Plus Thai Dental Implant. Bangkok: STZ Mospace design; 2015. p. 12. Lacey DL, Timms E, Tan HL, Kelley MJ, Dunstan CR, ...

Conclusions : Relation between the stability of de...

Within the limitations of this study and cautious interpretation due to small number of implants/patients, the ISQ values were weakly correlated with both ALP and OC molecules in PICF during the healing period. The results also show that osteocalcin may be used as a biological marker for monitoring implant healing at 6, 8, 10, and 12 weeks after implant placement. The ISQ values showed high stabi...

Discussion : Relation between the stability of den...

Vogel and Marcotte [33] suggested that the correlation between mRNA and protein quantities is approximately 40%. As there are many mechanisms between transcription and translation, especially in human cell and protein stability, at the gene expression level, the transcription data is beneficial in making decisions about molecular candidates for future studies at the protein level. The colorimetric...

Discussion : Relation between the stability of den...

The main sources of ALP in GCF are neutrophils, bacteria within dental plaque, fibroblasts, and osteoblasts [28]. Plagnat et al. [29] suggested that longitudinal monitoring of ALP in PICF might confirm its possible use as a marker of implant failure. Considering the change in the median values of the ALP level over time, in the test group, the ALP level decreased at 1–4 weeks and then increased...

Discussion : Relation between the stability of den...

The results of this study show that, at the time of implantation, the ISQ values ranged between 67.5 and 83. The mean initial ISQ value was 77.0 ± 1.32. These findings are in harmony with those of previous studies [16, 18]. Tallarico et al. (2011) reported that the macro-design of dental implant affects the primary anchorage [16]. They suggested that the high initial ISQ value is a factor in ...

Results : Relation between the stability of dental...

At the implant site, the OC level continuously increased with time. According to the Friedman followed by Wilcoxon signed-rank tests, there was statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Results : Relation between the stability of dental...

Ten patients, seven females, and three males, aged 42.4 ± 11.99 years (range, 28 to 64 years), with either a first mandibular or second mandibular molar edentulous area, who required a single nonsubmerged implant participated in this study, as shown in Table 2. The implants used for all patients were 10 mm long and 5 mm in diameter. All patients completed the follow-up. None of the impla...

Methods : Relation between the stability of dental...

Data were analyzed by using SPSS 17.0 software (SPSS Inc., Chicago, IL, USA). Repeated measures analysis of variance was performed to evaluate the change in the ISQ values at each measurement. The independent samples t test was used to investigate the differences in implant stability in the patients’ gender and bone quality. The Friedman test, followed by the Wilcoxon signed-rank test, was used ...

Methods : Relation between the stability of dental...

The level of OC was measured by using commercially available ELISA kits (Human Osteocalcin Quantikine ELISA Kit, R&D Systems, Inc., Minneapolis, MN, USA) according to the manufacturer’s instructions. A 100 μl volume of Assay Diluent RD1-117 (R&D Systems) was added into each well of the microplate and then 50 μl of standard (0–64 ng/ml) or sample was added to each well. The microplate was ...

Methods : Relation between the stability of dental...

To observe the level of two bone formation biomarkers (alkaline phosphatase and osteocalcin) during the osseointegration period compared with control group using GCF from the first molar of the contralateral side of implant position, the sample collection of GCF was performed before the surgical procedure, immediately after the surgical operation and after 1, 2, 3, 4, 6, 8, 10, and 12 weeks. The ...

Methods : Relation between the stability of dental...

The study is a prospective clinical study during the 3-month healing period of implant. The study was approved by the Human Experimentation Committee, Faculty of Dentistry, Chiang Mai University. The study outline is shown in Fig. 1. Ten patients, who were partially edentulous in the mandibular posterior region for whom a single nonsubmerged implant was planned, participated in this study. All o...

Background : Relation between the stability of den...

Osteocalcin (OC) is the most plentiful noncollagenous protein of the bone matrix. It is secreted from odontoblasts, osteocytes, and osteoblasts, in order to bind hydroxyapatite and calcium during matrix mineralization [7]. It is one of the serological markers in the bone formation process. Numerous studies have shown increased OC levels in bone formation. However, increased OC level relates more t...

Background : Relation between the stability of den...

Dental implants have shown a high success rate for rehabilitation of edentulous patients if certain conditions are met during treatment. Nevertheless, the risk of failure remains difficult to predict. The achievement of osseointegration depends on many factors, such as a suitable host, biocompatible materials, careful surgery, and an appropriate healing time [1].The primary stability comes from th...

Background : Relation between the stability of den...

Dental implants have shown a high success rate for rehabilitation of edentulous patients if certain conditions are met during treatment. Nevertheless, the risk of failure remains difficult to predict. The achievement of osseointegration depends on many factors, such as a suitable host, biocompatible materials, careful surgery, and an appropriate healing time [1]. The primary stability comes from ...

Abstract : Relation between the stability of denta...

The purposes of this study were to examine the correlation between the stability of dental implants and bone formation markers during the healing period and to monitor the stability of dental implants using the resonance frequency analysis (RFA) method. The null hypothesis of the study is no correlation between the stability of dental implant and bone formation markers. The study is a prospective...

About this article : Customized SmartPeg for measu...

Dhaliwal, J.S., Albuquerque, R.F., Fakhry, A. et al. Customized SmartPeg for measurement of resonance frequency of mini dental implants. Int J Implant Dent 3, 4 (2017). https://doi.org/10.1186/s40729-017-0066-6 Download citation Received: 09 November 2016 Accepted: 13 January 2017 Published: 01 February 2017 DOI: https://doi.org/10.1186/s40729-017-0066-6

Rights and permissions : Customized SmartPeg for m...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Customized SmartPeg for measu...

Faculty of Dentistry, McGill University, 2001 McGill College Avenue, Suite 500, Montreal, Quebec, H3A 1G1, Canada Jagjit Singh Dhaliwal, Ali Fakhry & Jocelyne S. Feine Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil Rubens F. Albuquerque Jr Department of Zoology, Panjab University, Chandigarh, India Sukhbir Kaur PAPRSB Institute of Health Sci...

References : Customized SmartPeg for measurement o...

Dhaliwal J, Albuquerque R, Murshed, M, Tamimi, F, Feine, JS. A histomorphometric comparison of osseointegration with MDIs and standard implants. IADR/AADR/CADR 91st General Session, Seattle, Washington, USA, March 20–23, 2013 Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of b...

References : Customized SmartPeg for measurement o...

Barros RR, Novaes Jr AB, Muglia VA, Iezzi G, Piattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs. Clin Oral Implants Res. 2010;21(4):371–8. Epub 2010/02/05. Marin C, Bonfante EA, Granato R, Suzuki M, Granjeiro JM, Coelho PG. The effect of alterati...

References : Customized SmartPeg for measurement o...

Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8(3):226–33. Epub 1997/06/01. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the im...

References : Customized SmartPeg for measurement o...

Ersanli S, Karabuda C, Beck F, Leblebicioglu B. Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol. 2005;76(7):1066–71. Epub 2005/07/16. Bornstein MM, Chappuis V, von Arx T, Buser D. Performance of dental implants after staged sinus floor elevation procedures: 5-year results of a prospective study in partially edentulous patients...

References : Customized SmartPeg for measurement o...

Shatkin TE, Oppenheimer BD, Oppenheimer AJ. Mini dental implants for long-term fixed and removable prosthetics: a retrospective analysis of 2514 implants placed over a five-year period. Compend Contin Educ Dent. 2007;28(2):92–9. quiz 100-1. Epub 2007/02/27. Griffitts TM, Collins CP, Collins PC. Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Or...

References : Customized SmartPeg for measurement o...

Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg. 1969;3(2):81–100. Epub 1969/01/01. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11(5):491–501. Epub 1999/01/29. Lioubavina-Hack N, Lang NP, Karring T. Significance of primar...

Conclusions : Customized SmartPeg for measurement ...

The results of this animal study indicate that ISQ measurement of these single-piece MDIs is possible with the help of a custom-made SmartPeg and that 3M™ESPE™MDIs attain primary and secondary stability at the same levels as standard implants in the rabbit tibia.

Discussion : Customized SmartPeg for measurement o...

As there are no studies that provide data based on resonance frequency measurements for single-piece MDIs, the exact RFA threshold values for MDIs may have to be identified with more studies conducted in vivo. The resonance frequency assessment with a customized SmartPeg would be a useful tool to provide clinically useful information about the condition of the bone-implant interface of 3M™ ESPE...

Discussion : Customized SmartPeg for measurement o...

If the initial ISQ value is high, a small drop in stability normally levels out with time. A big drop in stability or decrease should be taken as a warning sign. Lower values are expected to be higher after the healing period. The opposite could be a sign of an unsuccessful implant, and actions should be taken accordingly. Studies have shown that the resonance frequency value is greatly associate...

Discussion : Customized SmartPeg for measurement o...

It is important to measure the Implant Stability Quotient (ISQ) of single-piece mini dental implants as they are becoming increasingly popular, with the concomitant increase in publications demonstrating their high survival and success rates. Although the clinical use of Osstell devices is also increasing, there is lack of studies on its use with single-piece implants, which do not have internal t...

Results : Customized SmartPeg for measurement of r...

The ISQ values obtained while calibrating the customized SmartPeg were similar to in vivo results. Median ISQ values at insertion and at 6 postoperative weeks were 53.3 (IQR 8.3) and 60.5 (5.5) for the 3M™ESPE™MDIs, and 58.5 (4.75) and 65.5 (9.3) for the Ankylos® implants, respectively, with no statistical difference (Figs. 2 and 3). The ISQ values of both 3M™ESPE™ MDI and Ankylos® (Fig...

Methods : Customized SmartPeg for measurement of r...

ISQ values were averaged and compared between implant types and times using Wilcoxon’s matched pairs signed-rank tests at a significance level of p 

Methods : Customized SmartPeg for measurement of r...

For the MDIs, a small longitudinal skin incision was made just distal to the tibia/femur joint. The tibia/femur head was exposed subperiosteally, and an osteotomy was performed with the pilot drill under copious irrigation with saline solution, transposing the cortical bone to the depth of 0.5 mm. The implants were aseptically transferred to the bone site and manually rotated clockwise while exer...

Methods : Customized SmartPeg for measurement of r...

Single use Osstell SmartPegs for standard implants are made from a soft metal with a zinc-coated magnet mounted on top of it and attached to the implants or abutments’ internal threads. As the company does not provide SmartPegs for one-piece implants, we developed a customized SmartPeg for mini dental implants (3M™ESPE™ MDIs), which do not have internal threads (Fig. 1). After confirming th...

Objective : Customized SmartPeg for measurement of...

The aim of the study is to test the feasibility of a customized SmartPeg for ISQ measurement of single-piece mini dental implants and to compare the primary stability of a standard and the mini dental implant (3M™ESPE™MDI) in a rabbit model after 6 weeks of healing.

Background : Customized SmartPeg for measurement o...

There are no published studies on the ISQ measurement of mini dental implants, as SmartPegs for these implants are not available till date. Since these are one-piece implants and do not have an internal thread for the SmartPeg’s attachment, a custom-made SmartPeg needs to be fabricated for ISQ measurement. Therefore, we developed and tested a customized SmartPeg for 3M™ESPE™ MDIs to measure ...

Background : Customized SmartPeg for measurement o...

Mechanical testing methods like reverse torque, or “pullout test,” have been used to study and measure the mechanical interface between implant and bone in various ways [22, 23]. The Branemark group has evaluated the mechanical properties of osseointegrated implants using torsion and pullout tests and lateral loading tests [24, 25]. Presence or absence of mobility and the bone level around the...

Background : Customized SmartPeg for measurement o...

Osseointegration refers to the phenomenon for close apposition of the bone to the surface of an implant with no interposing tissue that can be clinically demonstrated by absence of mobility [1, 2]. Obtaining primary stability seems to be a precondition for a successful osseointegration [3]. Dental implants have a success rate of over 90% and are available in various sizes with different surfaces [...

Abstract : Customized SmartPeg for measurement of ...

The new custom-made SmartPeg is suitable for measuring the Implant Stability Quotient of 3M™ESPE™MDIs. The primary stability of 3M™ESPE™MDIs is similar to the primary stability attained by standard implants in the rabbit tibia.

Abstract : Customized SmartPeg for measurement of ...

One-piece narrow diameter implants (NDIs) have been recommended as “Single-tooth replacements in the anterior zones, single posterior, multiple-unit fixed dental prosthesis (FDP), edentulous jaws to be rehabilitated with FDP, and edentulous jaws rehabilitation with overdentures in situations with reduced mesiodistal space or reduced ridge width.” (ITI consensus 2013). Since NDIs can be immedia...

Fig. 3. Mean bone loss at 6 months and 1 year. M...

Fig. 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 months was 0.2981 and at 1 year 0.6613 Fig. 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 months was ...

Fig. 2. ISQ values at placement, 6 weeks, 6 mont...

Fig. 2. ISQ values at placement, 6 weeks, 6 months, and 1 year. Mean and standard deviation of ISQ values taken at placement, 6 weeks, 6 months, and 1 year is presented. No statistical significant difference was determined between ISQ values at all time points. (p 

Fig. 1. Implant design. The OSPTX and OSP implants...

Fig. 1. Implant design. The OSPTX and OSP implants are manufactured from high-grade commercially pure titanium with surface roughness produced via a fluoride treatment process. The OSP implant is a screw-shaped self-tapping implant. The diameter used in this study was 4.0 mm. The implant length used in this study was 8 mm. The OSPTX implant has the same features as the OSP except the apex of t...

Table 2 Outcome success criteria : Comparative eva...

Implant success Clinically immobile when tested manually and/or with RFA (minimum ISQ = 65) Absence of peri-implant radiolucency present on an undistorted radiograph Absence of unresolved pain, discomfort, inf...

Table 1 Patient selection criteria : Comparative e...

Inclusion Male or female At least 18 years old Healthy enough to undergo routine implant surgery and subsequent dental treatment Partially edentulous requiring...

About this article : Comparative evaluation of the...

Simmons, D.E., Maney, P., Teitelbaum, A.G. et al. Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study. Int J Implant Dent 3, 16 (2017). https://doi.org/10.1186/s40729-017-0078-2 Download citation Received: 18 January 2017 Accepted: 22 April 2017 Published: 02 May 2017 DOI: https://doi.org/10.1186/s40729-01...

Rights and permissions : Comparative evaluation of...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Author information : Comparative evaluation of the...

Department of Periodontics, Louisiana State University Health Sciences Center School of Dentistry, 1100 Florida Avenue, New Orleans, LA, 70119, USA David E. Simmons, Pooja Maney, Austin G. Teitelbaum, Susan Billiot & A. Archontia Palaiologou Tulane University SPHTM, 1440 Canal St, Suite 2001, New Orleans, LA, 70130, USA Lomesh J. Popat You can also search for this author in ...

References : Comparative evaluation of the stabili...

De Bruyn H, Raes F, Cooper LF, Reside G, Garriga JS, Tarrida LG, et al. Three-years clinical outcome of immediate provisionalization of single Osseospeed() implants in extraction sockets and healed ridges. Clin Oral Implants Res. 2013;24(2):217–23. Ebler S, Ioannidis A, Jung RE, Hammerle CH, Thoma DS. Prospective randomized controlled clinical study comparing two types of two-piece dental impla...

References : Comparative evaluation of the stabili...

O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res. 2004;15(4):474–80. Schwartz-Arad D, Herzberg R, Levin L. Evaluation of long-term implant success. J Periodontol. 2005;76(10):1623–8. Alves CC, Neves M. Tapered implants: from indications to advantages. Int J Periodontics Restora...

References : Comparative evaluation of the stabili...

Anitua E, Orive G. Short implants in maxillae and mandibles: a retrospective study with 1 to 8 years of follow-up. J Periodontol. 2010;81(6):819–26. Feldman S, Boitel N, Weng D, Kohles SS, Stach RM. Five-year survival distributions of short-length (10 mm or less) machined-surfaced and Osseotite implants. Clin Implant Dent Relat Res. 2004;6(1):16–23. Felice P, Cannizzaro G, Checchi V, March...

Notes : Comparative evaluation of the stability of...

DENTSPLY International, Susquehanna Commerce Center, 221 West Philadelphia Street, York, PA 17401 I-CAT 17 19; Imaging Services International LLC, 1910 North Penn Rd., Hatfield, PA 19440 Intra-Lock International, 6560 S. West Rogers Circle, Suite 24, Boca Raton, FL 33487 Osstell USA, 6700 Alexander Bell Drive, Suite 200, Columbia, MD 21046 ImageJ 1.50i Wayne Rasband National Institutes of Heal...

Conclusions : Comparative evaluation of the stabil...

Survival rates and stability of OSP and OSPTX implants was comparable. Osteotomy preparation either by the standard or by the soft bone surgical protocol had no significant effect on implant survival, success, and stability. Insertion torque presented a moderate to strong correlation with ISQ values at 6 weeks, 6 months, and 1 year. Insertion torque presented a weak correlation to ISQ values...

Discussion : Comparative evaluation of the stabili...

Insertion torque presented a moderate to strong correlation with ISQ values at 6 weeks, 6 months, and 1 year but not at time of implant insertion. This finding is in agreement with Acil et al. who reported no statistically significant correlation between insertion torque and ISQ at time of implant placement [22]. Although a strong correlation was found between insertion torque and bone loss at...

Discussion : Comparative evaluation of the stabili...

Augmentation of the maxillary sinus prior to dental implant placement is routinely performed in order to help patients restore their maxillary posterior dentition. Unfortunately, not all patients are candidates for this procedure due to either health, personal, or financial concerns. An alternative treatment without the need for a sinus elevation procedure is the use of a shorter implant. Research...

Results : Comparative evaluation of the stability ...

Overall implant survival rate was 93.3%. Two implants failed, one implant in group A (OSPTXSoft) and one in group B (OSPTXStd). Both implant failures occurred at the time of uncovery (at 6 weeks) and prior to loading of the implants and were attributed to lack of integration. With the exception of these two failed implants, there was 100% success for all remaining implants using the parameters de...

Methods : Comparative evaluation of the stability ...

ANOVA was used to compare the mean implant stabilities between the three groups. Post hoc testing was done via Tukey’s honestly significant differences test to calculate the differences between ISQ measurements at the time of implant placement, 6 weeks and 6 and 12 months (Fig. 2) as well as bone levels at 6 and 12 months (Fig. 3). The correlations of multiple parameters such as insertion t...

Methods : Comparative evaluation of the stability ...

Following proper approval by the LSUHSC Institution Review Board (LSUNO IRB#7438), 27 (30 implant sites) systemically healthy patients at least 18 years old were enrolled in the study and randomly divided into three groups as follows (inclusion and exclusion criteria are described in detail in Table 1): Group A received 10 OSPTX implants using the soft bone surgical protocol (OSPTXSoft). G...

Background : Comparative evaluation of the stabili...

A recent systematic review by Stocchero et al. concluded that an undersized drilling protocol in soft bone is an effective way to enhance insertion torque but recommended that further clinical studies are needed to confirm these data [18]. Our study was designed to address this question, as it compared the standard drilling protocol to a soft bone protocol. Our study hypothesis is that the stabil...

Background : Comparative evaluation of the stabili...

Dental implants are now a widely accepted treatment option for the replacement of missing teeth. The therapeutic goal of dental implants is to support restorations that replace single or multiple missing teeth so as to provide patient comfort, function, and esthetics as well as assist in the ongoing maintenance of remaining intraoral and perioral structures. However, anatomic limitations such as t...

Abstract : Comparative evaluation of the stability...

Survival and stability of OSPTX and OSP implants is comparable. Osteotomy preparation by either standard or soft bone surgical protocol presented no significant effect on implant survival and stability for the specific implant designs.

Abstract : Comparative evaluation of the stability...

The purpose of this study was to compare a parallel wall design implant to a tapered apex design implant when placed in the posterior maxilla using two different surgical protocols. Twenty-seven patients (30 implants) were divided into three groups. All implants were 4 mm wide in diameter and 8 mm long. Group A received 10 tapered implants (OSPTX) (Astra Tech OsseoSpeed TX™) using the soft b...

Fig. 7. Vestibular view of the final restoration :...

Fig. 7. Vestibular view of the final restoration Fig. 7. Vestibular view of the final restoration

Fig. 6. Occlusal view of the final restoration. In...

Fig. 6. Occlusal view of the final restoration. In this case, with the longest cantilever extension on a final restoration within this collective Fig. 6. Occlusal view of the final restoration. In this case, with the longest cantilever extension on a final restoration within this collective

Fig. 5. One-year post-surgery panoramic radiograph...

Fig. 5. One-year post-surgery panoramic radiograph with final restoration Fig. 5. One-year post-surgery panoramic radiograph with final restoration

Fig. 4. Occlusal view of implant-abutments 3 mont...

Fig. 4. Occlusal view of implant-abutments 3 months post-surgery at the first removal of the temporary restoration Fig. 4. Occlusal view of implant-abutments 3 months post-surgery at the first removal of the temporary restoration

Fig. 3. Fill-in of the occlusal perforations with ...

Fig. 3. Fill-in of the occlusal perforations with self-curing resin to connect the prostheses to the temporary titanium cylinders Fig. 3. Fill-in of the occlusal perforations with self-curing resin to connect the prostheses to the temporary titanium cylinders

Fig. 2. Preparation of the composite veneers for m...

Fig. 2. Preparation of the composite veneers for making the temporary restoration Fig. 2. Preparation of the composite veneers for making the temporary restoration

Fig. 1. Preparation of implant cavity through corr...

Fig. 1. Preparation of implant cavity through corresponding metal sleeves after extraction of the central incisors using a surgical template supported by hopeless remaining teeth Fig. 1. Preparation of implant cavity through corresponding metal sleeves after extraction of the central incisors using a surgical template supported by hopeless remaining teeth

Table 5 Marginal bone loss measured in mm : Six-im...

Collective Mesial Distal 1 year 55 months (40–84) 1 year ...

Table 4 Mean implant stability quotients (ISQ) of ...

Collective ISQ P At insertion 3 months Total (n = 57) 61.3 ± 7.8 ...

Table 3 Mean Periotest values (PT) of survived axi...

Collective PT value P At insertion 3 months Total (n = 57) −1.8 ± 2.4 ...

Table 2 Life table of implants : Six-implant-suppo...

Period # of implants # of failures Survival rate (%) Cumulative survival rate (%) 0 t...

Table 1 Diameters and lengths of immediately loade...

  Diameter Length 10 mm 12 mm 14 mm 16 mm Axial ...

About this article : Six-implant-supported immedia...

Wentaschek, S., Hartmann, S., Walter, C. et al. Six-implant-supported immediate fixed rehabilitation of atrophic edentulous maxillae with tilted distal implants. Int J Implant Dent 3, 35 (2017). https://doi.org/10.1186/s40729-017-0096-0 Download citation Received: 14 March 2017 Accepted: 13 July 2017 Published: 25 July 2017 DOI: https://doi.org/10.1186/s40729-017-0096-0

Rights and permissions : Six-implant-supported imm...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Ethics declarations : Six-implant-supported immedi...

The retrospective data analysis was conducted in accordance with the Helsinki Declaration of 1975, as revised in 2008, and all patients signed an informed consent. After consulting the local ethic committee, the decision was that due to the retrospective character of this study, with no additional data acquisition, no ethical approval is needed according to the hospital laws of the appropriate sta...

Author information : Six-implant-supported immedia...

Department of Prosthetic Dentistry, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany S. Wentaschek & S. Hartmann Department of Oral and Maxillofacial Surgery - Plastic Surgery, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany C. Walter & W. Wagner You can also search for ...

Acknowledgements : Six-implant-supported immediate...

The authors would like to thank Bredent Medical (Senden, Germany) for providing the 3D-planning system and supporting the treatment nonfinancially.

References : Six-implant-supported immediate fixed...

Download references

References : Six-implant-supported immediate fixed...

Bayer G, Kistler F, Kistler S, Adler S, Neugebauer J. Sofortversorgung mit reduzierter Implantatanzahl: Wissenschaftliche Konzeption und klinische Ergebnisse. Berlin: Quintessenz; 2011. Hanley JA. Receiver operating characteristic (ROC) methodology: the state of the art. Crit Rev Diagn Imaging. 1989;29(3):307–35. Atieh MA, Alsabeeha NH, Payne AG, de Silva RK, Schwass DS, Duncan WJ. The prognos...

References : Six-implant-supported immediate fixed...

Pommer B, Mailath-Pokorny G, Haas R, Busenlechner D, Furhauser R, Watzek G. Patients’ preferences towards minimally invasive treatment alternatives for implant rehabilitation of edentulous jaws. Eur J Oral Implantol. 2014;7(Suppl 2):S91–109. Monje A, Suarez F, Galindo-Moreno P, Garcia-Nogales A, Fu JH, Wang HL. A systematic review on marginal bone loss around short dental implants (

Abbreviations : Six-implant-supported immediate fi...

Area under the curve Implant stability quotient Periotest Receiver operating characteristic

Conclusions : Six-implant-supported immediate fixe...

Within the limits of this small group (n = 10 patients/60 implants), the failure rate of the analyzed implant system (n = 3 respective 5% implant loss) seems to be comparable with other immediate-loading protocols. On the other side, the implant loss rate of tilted implants (n = 2 of 20) in the atrophic upper jaw was quite high, but still, the aimed treatment concept could be achieved in eve...

Discussion : Six-implant-supported immediate fixed...

Between baseline and first removal of the temporary restoration after 3 months, the mean ISQ increased and the mean PT value decreased significantly in the axial and tilted implants. This is in contrast to some other studies which evaluated no significant differences of stability parameters between primary and secondary stability with immediate loading in edentulous maxilla [16, 21, 22]. The pre...

Discussion : Six-implant-supported immediate fixed...

The overall implant survival rate of 95% is slightly lower than the reported mean survival rates of the concept of tilted implants and immediate loading in edentulous jaws [11] but still close to them and maybe more comparable to investigations in which implants were also immediately loaded in the edentulous maxilla which were partly placed in fresh extraction sites [15, 16]. Nevertheless, what is...

Results : Six-implant-supported immediate fixed re...

After the temporary restoration with a fixed prosthesis, all 10 patients selected a fixed final restoration. These consisted of a cast metal framework with a full ceramic veneering including the replacement of at least the second premolars. They were made after a new impression on the abutment level (Figs. 6 and 7). The neck of the 20 tilted distal implants was positioned in region 4 (n = 5 impl...

Results : Six-implant-supported immediate fixed re...

Ten patients with a mean age at implant insertion of 64 ± 11.3 years (range 38 to 81 years; six women, four men) were included. Sixty titanium screw implants (Table 1) were inserted and immediately loaded between 09/2009 and 01/2013. Seven patients had remaining teeth until implant surgery (two patients with 4, four patients with 7, and one patient with 12 teeth). Twenty-one (35%) of the 60 ...

Methods : Six-implant-supported immediate fixed re...

Changes in marginal bone level were measured using the routinely made digital panoramic radiographs if these were available. The measurement tool was calibrated with the known respective implant length. To evaluate the bone loss, the difference was formed between the bone level at follow-up examination (Fig. 5) and at implant placement which is the baseline. An implant was considered as successfu...

Methods : Six-implant-supported immediate fixed re...

The patients were screened with preliminary panoramic radiographs, and since all the implants were 3D planned (SKYplanX™ program, Bredent GmbH, Senden, Germany) and inserted with a guiding template, a cone-beam CT (CBCT) was obtained eventually (KaVo 3D eXam™ unit, KaVo Dental GmbH, Biberach/Riss, Germany). The drillings were performed using a 3D-planned surgical template with different metal...

Methods : Six-implant-supported immediate fixed re...

In a retrospective study, all patients with immediately loaded implants in an edentulous maxillae with limited posterior ridge dimensions that received an equal concept were included if they had a follow-up of at least 3 years. The concept contained immediate loading with distal tilted implants and six implants per edentulous maxillae of a single implant system (blueSky™ implants, Bredent GmbH,...

Background : Six-implant-supported immediate fixed...

For a few years, there has been a trend towards minimally invasive implant treatment concepts avoiding bone augmentation even in very atrophic edentulous jaws. These concepts aim to make an implant treatment with a shorter duration, with less inconvenience such as swelling or pain and possibly also economically more attractive [1]. If the implant treatment is less invasive, because of the possible...

Abstract : Six-implant-supported immediate fixed r...

The aim of this retrospective study was to evaluate the treatment outcome of six Bredent blueSky™ implants (Bredent GmbH, Senden, Germany) immediately loaded with a fixed full-arch prosthesis (two tilted posterior and four axial frontal and premolar implants). All 10 patients with atrophic edentulous maxillae being treated with a standardized procedure from 09/2009 to 01/2013, who had a follow-...

Fig. 4. Scatterplot depicting indirect calculated ...

Fig. 4. Scatterplot depicting indirect calculated and direct measured ISQ values of the tested implants Fig. 4. Scatterplot depicting indirect calculated and direct measured ISQ values of the tested implants

Fig. 3. Example of a typical autospectrum pointing...

Fig. 3. Example of a typical autospectrum pointing to a 1 maximum RF based on 1000 measurements in case of a Straumann test implant Fig. 3. Example of a typical autospectrum pointing to a 1 maximum RF based on 1000 measurements in case of a Straumann test implant

Fig. 2. Clamped Osstell probe orientated towards a...

Fig. 2. Clamped Osstell probe orientated towards a Smartpeg mounted on a test implant. Note the red laser beam dot on the flat surface of the Smartpeg hexagon part Fig. 2. Clamped Osstell probe orientated towards a Smartpeg mounted on a test implant. Note the red laser beam dot on the flat surface of the Smartpeg hexagon part

Fig. 1. Concept for study of deflection and stiffn...

Fig. 1. Concept for study of deflection and stiffness aspects of implant-Smartpeg complex by laser Doppler vibrometry. Intentional partial imbedding of implants allows to detect both the deflection of implant and Smartpeg separately at different vertical levels by changing the position of the laser beam Fig. 1. Concept for study of deflection and stiffness aspects of implant-Smartpeg complex ...

Table 2 Mean values (± SD) of recorded maximum ...

Batch # Implant system Implant length (mm) Implant diameter (mm) Mean measured resonance freq (kHz) SD meas...

Table 1 Published secondary implant stability valu...

Author and study Implant position (implant number) Mean ISQ values at given time-point post-insertion Type of Osstell device used Barewal et al. 2003 [10] ...

About this article : ISQ calculation evaluation of...

Debruyne, S., Grognard, N., Verleye, G. et al. ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency. Int J Implant Dent 3, 44 (2017). https://doi.org/10.1186/s40729-017-0105-3 Download citation Received: 11 April 2017 Accepted: 28 September 2017 Published: 12 October 2017 DOI: https://doi.org/10.1186/s40729-017-0105-3

Rights and permissions : ISQ calculation evaluatio...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Ethics declarations : ISQ calculation evaluation o...

Stijn Debruyne, Nicolas Grognard, Gino Verleye, Korneel Van Massenhove, Dimitrios Mavreas, and Bart Vande Vannet declare that they have no competing interests. Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information : ISQ calculation evaluation of...

Correspondence to Nicolas Grognard.

Author information : ISQ calculation evaluation of...

Department of Mechanics, Research Group Propolis, School of Engeneering Sciences, Katholieke Hoge School Brugge-Oostende, Ostend, Belgium Stijn Debruyne Kliniek Royal, Koningstraat 41, 8400, Ostend, Belgium Nicolas Grognard CHIR-Unit Dentistry–ORHE, Department of Orthodontics, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Laarbeeklaan 103, 1090, Brussels, Belgium Nicolas Gro...

References : ISQ calculation evaluation of in vitr...

Han J, Lulic M, Lang NP. Factors influencing resonance frequency analyis assessed by Osstell Mentor during implant issue integration: II: implant surface modifications and implant diameter. Clin Oral Implants Res. 2010;6:605–11. Bornstein M, Hart C, Halbritter S, Morton D, Buser D. Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6...

References : ISQ calculation evaluation of in vitr...

Adell R, Lekholm U, Brånemark PI. Surgical procedures. In: Brånemark PI, Zarb GA, Albrektsson T, editors. Tissue integrated prothese. Osseointegration in clinical dentistry. Chigaco: Quintessence; 1985. p. 211–32. Strid K. Radiographic procedures. In: Brånemark P-I, Zarb G, Albrektsson T, editors. Tissue integrated prothese. Osseointegration in clinical dentistry. Chigaco: Quintessence; 1985...

Conclusions : ISQ calculation evaluation of in vit...

In conclusion, the present study demonstrated that the algorithm applied and provided by Osstell to calculate ISQ values is correct, making the laboratory procedure valuable for future research focused on stiffness aspects of the implant-Smartpeg complex and its possible influence on the overall RFA measurement. Vice versa, the present study demonstrates the correctness of the actual applied algor...

Discussion : ISQ calculation evaluation of in vitr...

The focus of this in vitro study was to develop a laboratory method, intended for future research of aspects of implant-Smartpeg complex stiffness and its possible influence on the overall RFA-based implant stability determination. In the past, other laboratory methodologies have been engineered to investigate implant deflection and/or lateral displacement by means of transducers. A setup using a ...

Results : ISQ calculation evaluation of in vitro l...

Mean values (± SD) of recorded maximum RF values, calculated indirect ISQ values, and direct recorded ISQ values for Ankylos (A) and Straumann (S) test implants are shown in Table 2. Using the Shapiro-Wilk test for indirect ISQ (p = 0.05) and direct ISQ (p = 0.02), we can conclude that both indirect and direct ISQ measures are not drawn from a normal distribution (data not shown). Bot...

Methods : ISQ calculation evaluation of in vitro l...

In total, for each given implant type with a given diameter/length configuration, 25 measurements for indirect and 5 measurements for direct ISQ computing were performed. The SPSS statistical software package 22.0 (IBM SPSS, Chicago, USA) was used. A Shapiro-Wilk test was used to verify distribution normality for both direct and indirect determined ISQ values. The paired sample t test and the Wil...

Methods : ISQ calculation evaluation of in vitro l...

The Smartpeg excitation mode was exactly performed as described above. Notation of the maximum resonance frequency for indirect measurements is followed by notation of direct ISQ value on the display of Osstell IDx device. Positioning of the probe was not changed during indirect and direct recordings for a given test implant. Each resin block contained five identical implants with attached Smartp...

Methods : ISQ calculation evaluation of in vitro l...

Test implants originating from various manufacturers were investigated. Straumann sandblasted, large-grit, acid-etched (SLA)® tissue level standard implants (Straumann AG, Basel, Switzerland) with the following diameter: length configurations were 3.3–12 mm (RN connection), 3.3–4.1 mm (RN connection), and 4.8–8 mm (WN connection), Ankylos Cell Plus® surfaced B-implant types (Dentsply Im...

Background : ISQ calculation evaluation of in vitr...

Laser Doppler vibrometry possesses a working principle based on the so-called Doppler effect and allows non-contact quantitative measurement of vibration (https://en.wikpedia.org/wiki/Laser_scanning_vibrometry, 2017). The Doppler effect itself finds its origin when a light beam is backscattered on a vibrating surface and experiences a change in wave phase (https://en.wikipedia.org/wiki/Doppler_eff...

Background : ISQ calculation evaluation of in vitr...

The computed ISQ value is based on the following calculation formulae: Hereby, f denotes the measured maximum resonance frequency (RF). Coefficients a, b, c, d, and e are property information of Osstell (Osstell AB, Gothenburg, Sweden). The coefficients were provided for internal use under the agreement of no publication. From clinical reports [10,11,12,13,14,15,16] listed in Table 1, it ...

Background : ISQ calculation evaluation of in vitr...

At present, multiple implant stability assessment methodologies are used, both of invasive and non-invasive nature, including percussion test [1], X-ray evaluation [2], cutting resistance during implant insertion (e.g., electronic insertion torque determination) [3], turn-out or reverse torque test [4], Periotest® [5, 6], and resonance frequency analysis (“RFA”), e.g., the Osstell method [7, ...

Abstract : ISQ calculation evaluation of in vitro ...

Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be investigated in vi...

Fig. 5. a Postoperative orthopantomogram. b Follow...

Fig. 5. Fig. 5. a Postoperative orthopantomogram. b Follow-up orthopantomogram. c Follow-up standard periapical radiogram (implants i42 and i44). d Follow-up standard periapical radiogram (implants i32 and i34)

Fig. 4. a–h Prosthetic restauration—follow-up ...

mandible.) Fig. 4. a–h Prosthetic restauration—follow-up examination. Intraoral and perioral views of a rehabilitated female patient. (She asked explicitly only for implantological treatment in the mandible.)

Fig. 3. a Primary implant stability. The histogram...

Fig. 3. ution of the implant stability quotients (ISQ) for both jaws measured by resonance frequency analysis (Osstell AB, Göteborg, Sweden). b Secondary implant stability. The histogram shows the distribution of the implant stability quotients (ISQ) of osseointegrated implants. According to the measurement implant stability was classified as low with ISQ values  70 [34] Fig. 3. a Primary ...

Fig. 2. Cumulative implant survival over the follo...

Fig. 2. Cumulative implant survival over the follow-up period. The Kaplan-Meyer diagram visualises the analysis of implant survival in the maxilla and in the mandible (log rank test, p = 0.173) over the follow-up period up to 37 months (Table 4) Fig. 2. Cumulative implant survival over the follow-up period. The Kaplan-Meyer diagram visualises the analysis of implant survival in the maxi...

Fig. 1. a Closed short expandable dental implant (...

Fig. 1. he implant-abutment connection is characterised by an internal hexagon for rotation stability, combining the advantages of conical and parallel surfaces to reduce microgaps and micromovement [68]. The microthread concept and platform switching concept are implemented in the implant shoulder to reduce periimplant bone strain [53]. b Manual fixation of the expansion tool. Take note of the...

Table 4 Clinical characteristics of the study coho...

Patient Sex Age (years) Implant position (FDI) Indication categorya Bone quality Prosthetic treatment ...

Table 3 Prosthetic treatment protocol : Novel expa...

Type of prosthetic treatment Session Procedure Fixed denture (bridge) 1 Open impression ...

Table 2 Surgical treatment protocol : Novel expand...

Surgical protocol Bone quality   D1 D2 D3 D4 1. Drilli...

Table 1 Patient recruitment : Novel expandable sho...

Inclusion criteria Exclusion criteria 1. Adult patients, male and female 1. Comorbidity ASA category ≥ III 2. Partially/totally edentulous patients ...

About this article : Novel expandable short dental...

Reich, W., Schweyen, R., Heinzelmann, C. et al. Novel expandable short dental implants in situations with reduced vertical bone height—technical note and first results. Int J Implant Dent 3, 46 (2017). https://doi.org/10.1186/s40729-017-0107-1 Download citation Received: 18 August 2017 Accepted: 12 October 2017 Published: 30 October 2017 DOI: https://doi.org/10.1186/s40...

Rights and permissions : Novel expandable short de...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were...

Additional files : Novel expandable short dental i...

Dataset presenting relevant raw data. (SAV 3 kb)

Ethics declarations : Novel expandable short denta...

WR is a senior physician at the University Hospital Halle, Martin Luther University Halle-Wittenberg, Department of Oral and Plastic Maxillofacial Surgery, Halle/Saale, Germany.RS is a clinical research associate at the University School of Dental Medicine, Department of Prosthetic Dentistry, Martin Luther University Halle-Wittenberg, Halle/Saale, Germany.CH is a consultant at the University Hospi...

Ethics declarations : Novel expandable short denta...

WR is a senior physician at the University Hospital Halle, Martin Luther University Halle-Wittenberg, Department of Oral and Plastic Maxillofacial Surgery, Halle/Saale, Germany. RS is a clinical research associate at the University School of Dental Medicine, Department of Prosthetic Dentistry, Martin Luther University Halle-Wittenberg, Halle/Saale, Germany. CH is a consultant at the University H...

Author information : Novel expandable short dental...

Correspondence to Waldemar Reich.

Author information : Novel expandable short dental...

Department of Oral and Plastic Maxillofacial Surgery, Martin Luther University Halle-Wittenberg, Ernst-Grube Str. 40, 06120, Halle (Saale), Germany Waldemar Reich, Christian Heinzelmann, Bilal Al-Nawas & Alexander Walter Eckert University School of Dental Medicine, Department of Prosthetic Dentistry, Martin Luther University Halle-Wittenberg, Magdeburger Straße 16, 06112, Halle (Saale), Ger...

Acknowledgements : Novel expandable short dental i...

The authors are grateful to the DenTack Company for providing some of the implants and components used in this study. The courtesy of Oz Vachtenberg is acknowledged for providing Fig. 1a–f and the movie clip. There are no financial supports or conflicts of interest associated with this publication that could have influenced its outcome. We thank the Osstell Company, which supplied the RFA devic...

References : Novel expandable short dental implant...

Mishra SK, Chowdhary R, Kumari S. Microleakage at different implant abutment interface: a systematic review. J Clin Diagn Res. 2017;11(6):ZE10–5. Feichtinger M, Gaggl A, SChultes G, Kärcher H. Evaluation of distraction implants for prosthetic treatment after vertical alveolar ridge distraction: a clinical investigation. Int J Prosthodont. 2003;16(1):19–24. Pradeep PR, Kasti KJ, Ananthakrish...

References : Novel expandable short dental implant...

Gehrke SA, Pérez-Albacete Martinez C, Piattelli A, Shibli JA, Markovic A, Calvo Guirado JL. The influence of three different apical implant designs at stability and osseointegration process: experimental study in rabbits. Clin Oral Implants Res. 2017;28(3):355–61. Herrero-Climent M, Santos-Garcia R, Jaramillo-Santos R, Romero-Ruiz MM, Fernandez-Palacin Lazaro-Calvo P, Bullon P, Rios-Santos JV....

References : Novel expandable short dental implant...

Malmstrom H, Gupta B, Ghanem A, Cacciato R, Ren Y, Romanos GE. Success rate of short dental implants supporting single crowns and fixed bridges. Clin Oral Implants Res. 2016;27(9):1093–8. Garfield RE. An expandable implant fixture. Dent Implantol Updat. 1998;9(5):37–40. Nowzari H, Chee W, Tuan A, Abou-Rass M, Landesman HM. Clinical and microbiological aspects of the Sargon immediate load imp...

References : Novel expandable short dental implant...

Brenner M, Brandt J, Lauer HC. Prothetische Versorgung auf kurzen Implantaten. Zahnmedizin up2date. 2014;2:123–42. (German) Eitner S, Wichmann M, Schlegel KA, Kollmannberger JE, Nickenig HJ. Oral health-related quality of life and implant therapy: an evaluation of preoperative, intermediate, and post-treatment assessments of patients and physicians. J Craniomaxillofac Surg. 2012;40(1):20–3. ...

References : Novel expandable short dental implant...

De Moraes SL, Verri FR, Santiago JF Jr, Almeida DA, de Mello CC, Pellizzer EP. A 3-D finite element study of the influence of crown-implant ratio on stress distribution. Braz Dent J. 2013;24(6):635–41. Moraes SL, Pellizzer EP, Verri FR, Santiago JF Jr, Silva JV. Three-dimensional finite element analysis on stress distribution in retention screws of different crown-implant ratios. Comput Methods...

References : Novel expandable short dental implant...

Thoma DS, Haas R, Tutak M, Garcia A, Schincaglia GP, Hämmerle CH. Randomised controlled multicenter study comparing short dental implants (6 mm) versus longer dental implants (11-15 mm) in combination with sinus floor elevation procedures. Part 1: demographic and patient-reported outcomes at 1 year of loading. J Clin Periodontol. 2015;42(1):72–80. Hentschel A, Herrmann J, Glauche I, Vollmer A,...

References : Novel expandable short dental implant...

Schwarz F, Terheyden H. Significance of dental implants for health care. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2011;54(9):1097–101. (German) Gates WD, Cooper LF, Sanders AE, Reside GJ, De Kok IJ. The effect of implant-supported removable partial dentures on oral health quality of life. Clin Oral Impl Res. 2014;25:207–13. Fretwurst T, Nack C, Al-Ghrairi M, Raguse JD, ...

Abbreviations : Novel expandable short dental impl...

Bone quality (density) World Dental Federation Implant stability quotient Resonance frequency analysis

Conclusion : Novel expandable short dental implant...

Initial results of the ongoing study confirm the feasibility and safety of the employed system. The implant type seems to be useful for all bone qualities and shows high initial and secondary biomechanical stability in the maxilla and mandible. Long-term follow-up will be needed in validating these initial results in a larger 3-year clinical trial. Crestal bone changes should be evaluated in a la...

Discussion : Novel expandable short dental implant...

Comparable studies displayed at 24 months a crestal bone loss of 0.5–0.6 mm [15]. Other authors reported at 2, 3 and 5 years a mean loss of 0.57, 0.55 and 0.53 mm, respectively, in the mandible (without significant change after 1 year) [10]. On the other hand, randomised controlled trials demonstrated 1 year after loading periimplant marginal bone loss of 0.7 mm [70] and 1.1 mm [7] in th...

Discussion : Novel expandable short dental implant...

Contrary to conventional hollow-screw implants (only marginal gap), a problem of the expandable implant is the presence of gaps down to the apical region. Former microbial assessment of different implant-abutment interfaces displayed that none of the marginal connections had the capacity to prevent microbial leakage [63,64,65]. Therefore, an apical microleakage (comparable to distractable implants...

Discussion : Novel expandable short dental implant...

Regarding resonance frequency analysis, the values are related to bone quality and quantity as well as the exposed implant height above the alveolar crest, which depends on the type of implant and insertion technique [55,56,57]. Our results (primary stability in the maxilla 66.9 ± 8.9 ISQ units and in the mandible 72.5 ± 11.1 ISQ units; secondary stability in the maxilla 66.4 ± 10.0...

Discussion : Novel expandable short dental implant...

Several investigators analysed the preferred indications of short dental implants in the posterior mandible or maxilla and outlined the cost efficiency compared to additional vertical augmentations. In the present trial, we used a new short implant in both jaws and nearly all possible indication categories were represented, which proves the broad versatility (Table 4). In our study, two implant ...

Discussion : Novel expandable short dental implant...

Recent literature has shown that short implants have achieved growing acceptance in the field of oral implantology [9, 10, 39, 40]. Since the last years, concern has decreased about the length of endosseous implants; it should be noted that all extraoral screw implants are short implants [41, 42]. Nevertheless, there are local physiological and biomechanical differences regarding long-term stabili...

Results : Novel expandable short dental implants i...

Over the follow-up period, the mean crestal bone changes after loading were as follows (each compared to the baseline): in the first year, 1.0 ± 0.9 mm 95% CI (0.5; 1.5) in the maxilla and 0.7 ± 0.4 mm 95% CI (0.5; 1.0) in the mandible (p = 0.011; independent t test), and in the second year, 1.3 ± 0.8 mm 95% CI (0.8; 1.7) in the maxilla and 1.0 ± 0.7 mm 95% CI (0.6; 1.4...

Results : Novel expandable short dental implants i...

The first results of this longitudinal study include data from 9 patients with an average age of 57 years (range from 44 to 80) in whom 30 implants were inserted (maxilla n = 15, mandible n = 15). All 30 implants in the 9 patients could be inserted without intraoperative problems. Based on intraoperative and radiological findings, the bone quality was assessed as follows: D1 in n = 2,...

Material and methods : Novel expandable short dent...

All patients were pseudonymised, parameters were attached to a databank and analysed statistically (Additional file 2). Statistical analyses were performed using statistics software (IBM SPSS statistics, version 20, Chicago, IL, USA). The descriptive statistics presented the frequency and distribution of several occurrences as well as combinations of certain features. Analytical statistics were p...

Material and methods : Novel expandable short dent...

Simulation of the expansion process. At the end of the expansion process, a minimal snap back is realised. (MP4 9407 kb) Planning of the implantological treatment followed usual clinical and radiological examination and, concerning the position and number of implants, the recommended categories from the German consensus conference [35]. The drilling sequence, condensing preparation (where necess...

Material and methods : Novel expandable short dent...

The study was designed as a prospective monocentric longitudinal cohort study according to the STROBE criteria. The participants of this study were recruited at the university hospital of Martin Luther University Halle-Wittenberg, Department of Oral and Plastic Maxillofacial Surgery, implantological consultation from 2014 (June) until 2015 (June). Inclusion and exclusion criteria of adult patients...

Introduction : Novel expandable short dental impla...

It is known that achievement of primary stability is one precondition for osseointegration and treatment success. There are few reports of immediate [14] and early (6 weeks) functional loading of short implants [28]. This is related to good bone quality, implant design or implant site preparation (e.g. under-drilling). However, under-drilling of the crestal aspect may lead to decreased bone-to-im...

Introduction : Novel expandable short dental impla...

Endosseous implants have been established over several decades. The evaluation of treatment results under biomechanical, physiological, psychological, social and economic aspects has been well documented [1]. Furthermore, patient-based outcomes reveal a predictable gain in oral health-related quality of life [2]. Especially in patients with limited vertical bone height, process of treatment is ex...

Abstract : Novel expandable short dental implants ...

Short implants often have the disadvantage of reduced primary stability. The present study was conducted to evaluate the feasibility and safety of a new expandable short dental implant system intended to increase primary stability. As a “proof of concept”, a prospective clinical cohort study was designed to investigate intraoperative handling, primary and secondary implant stability (resonanc...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7-mm-length dental implant at the time of its placement at the mandibular left second premolar in a 63-year-old Caucasian female. b Radiographic image of a three-unit fixed partial denture upon its initial placement. The dental implant is the anterior abutment with the prosthesis screw retained to it. The distal abutment is the mandibular left sec...

Fig. 1. a Initial radiograph exposed at abutment i...

Fig. 1. a Initial radiograph exposed at abutment installation on a 5-mm-wide by 7-mm-length dental implant used to help support a removable partial denture for a 71-year-old Caucasian male. b Radiograph of the area taken at 82 months demonstrates good bone stability. c Clinical image of the area 82 months later. Soft tissue remains healthy. The two teeth anterior are in the process of receivin...

Table 5 Resonance frequency analysis : A 1–7 ye...

Time ISQ n Implant insertion 73.6 ± 8.1 86 1–4 weeks ...

Table 4 Implant survival, life table analysis : A ...

Interval Implants Failed Not followed CSR (%) Insertion to 1 year ...

Table 3 Specification of failed implants (three im...

Sex Age Smoker Risk factors Position Implant diameter ...

Table 2 Implant and site-related specifications : ...

  Number Percent Jaw Maxilla 60 69.8 Mandible ...

Table 1 Patient demographics : A 1–7 year retro...

  Number Percent Age (years) 20–29 1 1.3 30–39 ...

About this article : A 1–7 year retrospective f...

Rosen, P.S., Sahlin, H., Seemann, R. et al. A 1–7 year retrospective follow-up on consecutively placed 7-mm-long dental implants with an electrowetted surface. Int J Implant Dent 4, 24 (2018). https://doi.org/10.1186/s40729-018-0136-4 Download citation Received: 08 January 2018 Accepted: 21 May 2018 Published: 23 August 2018 DOI: https://doi.org/10.1186/s40729-018-0136...

Rights and permissions : A 1–7 year retrospecti...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : A 1–7 year retrospective ...

The study was performed in compliance with the Declaration of Helsinki. Data collection was performed in such a manner that subjects could not be identified, and therefore, it was exempt from IRB review according to Federal Regulation 45 CFR 46.101(b). All participants consented to publish their information details through the clinic’s standard patient consent procedure. Also, all images appear...

Author information : A 1–7 year retrospective f...

Clinical Professor of Periodontics, Baltimore College of Dental Surgery, University of Maryland Dental School, Baltimore, MD, USA Paul S. Rosen Private Practice limited to Periodontics and Dental Implants, 907 Floral Vale Boulevard, Yardley, PA, 19067, USA Paul S. Rosen Neoss Ltd, Gothenburg, Sweden Herman Sahlin University Clinic of Craniofacial, Maxillofacial and Oral Surgery, Vienna, Aust...

Availability of data and materials : A 1–7 year...

Due to the ethical and legal responsibility to respect participants’ rights to privacy and to protect their identity, the clinical dataset is not made publicly available.

References : A 1–7 year retrospective follow-up...

Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Survival rates of short (6 mm) micro-rough surface implants: a review of literature and meta-analysis. Clin Oral Implants Res. 2014;25(5):539–45. Chrcanovic BR, Albrektsson T, Wennerberg A. Diabetes and oral implant failure: a systematic review. J Dent Res. 2014;93(9):859–67. Giro G, Chambrone L, Goldstein A, Rodrigues JA,...

References : A 1–7 year retrospective follow-up...

Jemt T, Olsson M, Franke SV. Incidence of first implant failure: a retroprospective study of 27 years of implant operations at one specialist clinic. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e501–10. Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G. Impact of dental implant length on early failure rates: a meta-analysis of observational studies. J Clin Periodontol. 2011;38(9):856...

Abbreviations : A 1–7 year retrospective follow...

Cumulative survival rate Implant stability quotient Insertion torque Odds ratio Resonance frequency analysis Relative risk

Conclusion : A 1–7 year retrospective follow-up...

The current retrospective consecutive case series study provides preliminary data that treatment with 7-mm-length short implants with a hydrophilic electrowetted surface is a reasonable approach in sites with limited vertical bone dimension. It adds to the body of evidence supporting short implant use for compromised sites. The success seen might be attributed to the larger implant diameters that ...

Discussion : A 1–7 year retrospective follow-up...

Thirty-six percent of the implants in the study were placed in extraction sockets. Provided that sufficient initial implant stability is achieved, there should be no additional risk factors compared to implants in healed sites. Studies have shown no difference in marginal bone remodeling between immediately placed and delayed implants [15]. The biggest limitation of the current study is its very ...

Discussion : A 1–7 year retrospective follow-up...

A wide distribution in implant insertion torque (10–50 Ncm) was seen in the study. This reflects the variety of clinical situations in which the implants were placed. Assessments were made by using both the RFA value and the insertion torque as to first whether an implant should have been left to heal in the first place and if so, how this would be best accomplished, i.e., through its submergen...

Discussion : A 1–7 year retrospective follow-up...

This retrospective study is the first to look at short dental implants with a hydrophilic electrowetted surface. The survival data suggest that this treatment is a viable option to care. In a systematic review that identified 13 studies on implants shorter than 10 mm, the CSR from the individual studies ranged from 80 to 100% with a combined CSR of 98.3% after 5 years, 94.8% after 6 years, and ...

Results : A 1–7 year retrospective follow-up on...

The chart review identified 86 placed implants in 75 patients. Table 1 summarizes the patient demographics of the 75 patients. Patients ranged in age from 29 to 88 years with a mean of 61.0 ± 12.5 years. Twenty-seven of the patients were males and 48 were females. Table 2 summarizes the implant and site-related information of the 86 placed implants. Mean insertion torque was 30.1 ± 7...

Methods : A 1–7 year retrospective follow-up on...

Baseline parameters, both patient- and implant-related, as well as follow-up parameters (implant survival, follow-up time, and resonance frequency analysis) were collected from a review of the patient records. The main study parameters (principal outcome parameters) were defined to be implant loss and follow-up time. The cumulative survival rate was estimated. The influence of several factors on ...

Methods : A 1–7 year retrospective follow-up on...

A retrospective study on short 7 mm hydrophilic implants from a single center was conducted in a private practice limited to periodontics and surgical dental implant placements from one of the authors, PSR (Yardley, Pennsylvania, USA). An exhaustive chart review identified 75 patients for analysis that were treated with 86 short (7 mm) implants during a 5-year period (September 1, 2009, to Novem...

Background : A 1–7 year retrospective follow-up...

The aim of this retrospective consecutive case series study was to investigate implant survival rate and analyze possible factors affecting the survival of short implants placed in one surgical practice focused on implantology and periodontology in a temporal cohort.

Background : A 1–7 year retrospective follow-up...

In the past decades, the osseointegration rate of dental implants has dramatically increased, particularly in sites of softer dental bone, which may be attributed to the introduction of moderately roughened surfaces [1, 2]. Moreover, because of this increase in success, clinicians have attempted to push the envelope and place implants into sites that may provide a greater challenge as they wish to...

Abstract : A 1–7 year retrospective follow-up o...

This retrospective consecutive case series study was performed to determinate the survival rate and implant stability of short (7 mm length) dental implants with an electrowetted hydrophilic surface that were in function from 1 to 7 years. A retrospective chart review identified and evaluated 86 consecutively placed 7-mm-long dental implants (ProActive, Neoss Ltd., Harrogate, England) in 75 pat...

Fig. 3. One possible missing category (depicted as...

Fig. 3. One possible missing category (depicted as “X”) would be a bone type with thick cortical layer and sparse trabecular bone, which would have intermediate characteristics and behavior between the types with thick (2) or thin (3) cortical bones Fig. 3. One possible missing category (depicted as “X”) would be a bone type with thick cortical layer and sparse trabecular bone, which ...

Fig. 2. Preoperative CT image showing the site for...

Fig. 2. Preoperative CT image showing the site for the definition of the ROI (simulated area delimited by a yellow dashed line for illustration purpose) in the axial (a), coronal (b), and sagittal (6 × 6 mm) (c) sections Fig. 2. Preoperative CT image showing the site for the definition of the ROI (simulated area delimited by a yellow dashed line for illustration purpose) in the axial (...

Fig. 1. Clinical case of a short implant (4.1 ×...

Fig. 1. Clinical case of a short implant (4.1 × 6 mm) placed in the region of the left maxillary first molar. a Implant installed. b Insertion torque measurement using the manual torque wrench. c Implant with healing cap and flap suture. d Immediate periapical radiograph after surgery Fig. 1. Clinical case of a short implant (4.1 × 6 mm) placed in the region of the left maxillar...

Table 3 Comparison of CT mean gray values (average...

Variable Meana Std error 95% confidence interval P value (F; DF) Arch    

Table 2 Matrix of Spearman correlation coefficient...

Variables Torque Tactile CT visual MGV_avg MGV_axial M...

Table 1 Descriptive statistics of the sample : Rel...

Variable Frequency Mean SD 95% confidence interval Patient ...

About this article : Relation between insertion to...

Triches, D.F., Alonso, F.R., Mezzomo, L.A. et al. Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants. Int J Implant Dent 5, 9 (2019). https://doi.org/10.1186/s40729-019-0158-6 Download citation Received: 07 October 2018 Accepted: 06 January 2019 Published: 11 February...

Rights and permissions : Relation between insertio...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : Relation between insertion t...

This study was conducted in accordance with the tenets of the Declaration of Helsinki, and all procedures involving human subjects were approved by the ethics committee of the Pontifical Catholic University of Rio Grande do Sul/UBEA (ethical approval letter OF.CEP-772/10; research protocol CEP 10/05074). Written informed consent was obtained from all study participants. Diego Fernandes Triches, ...

Author information : Relation between insertion to...

All authors (1) made substantial contributions to the conception and/or design of the work or the acquisition, analysis, or interpretation of data for the work; (2) drafted the paper or revised it critically; (3) approved the final version of this manuscript; and (4) agreed to be accountable for all aspects of the work. Categories of authors’ contribution are as follows: concept/design (RSS, DFT...

Author information : Relation between insertion to...

Postgraduate Program in Dentistry, Pontifical Catholic University of Rio Grande do Sul (PUCRS), Dental School, Avenida Ipiranga, 6681 – Prédio 6, Porto Alegre, RS, 90619-900, Brazil Diego Fernandes Triches, Fernando Rizzo Alonso, Danilo Renato Schneider, Eduardo Aydos Villarinho, Maria Ivete Rockenbach, Eduardo Rolim Teixeira & Rosemary Sadami Shinkai Postgraduate Program in Dentistry,...

Acknowledgements : Relation between insertion torq...

The authors would like to thank Professor Helena de Oliveira and Dr. Geisa Medeiros for their early assistance with CT software. The work was supported by a research grant from Coordination for the Improvement of Higher Education Personnel (CAPES, Brazil; PNPD grant), the National Counsel of Technological and Scientific Development (CNPq, Brazil; Universal grant), and the International Team for I...

References : Relation between insertion torque and...

Kaya S, Yavuz I, Uysal I, Akkus Z. Measuring bone density in healing periapical lesions by using cone beam computed tomography: a clinical investigation. J Endod. 2012;38:28–31. Brosh T, Yekaterina BE, Pilo R, Shpack N, Geron S. Can cone beam CT predict the hardness of interradicular cortical bone? Head Face Med. 2014;10:12. Tatli U, Salimov F, Kürkcü M, Akoğlan M, Kurtoğlu C. Does cone be...

References : Relation between insertion torque and...

Nomura Y, Watanabe H, Honda E, Kurabayashi T. Reliability of voxel values from cone-beam computed tomography for dental use in evaluating bone mineral density. Clin Oral Implants Res. 2010;21:558–62. Reeves TE, Mah P, McDavid WD. Deriving Hounsfield units using gray levels in cone beam CT: a clinical application. Dentomaxillofac Radiol. 2012;41:500–8. Cassetta M, Stefanelli LV, Pacifici A, P...

References : Relation between insertion torque and...

Degidi M, Daprile G, Piattelli A. Determination of primary stability: a comparison of the surgeon’s perception and objective measurements. Int J Oral Maxillofac Implants. 2010;25:558–61. Alonso FR, Triches DF, Mezzomo LAM, Teixeira ER, Shinkai RSA. Primary and secondary stability of single short implants. J Craniofac Surg. 2018. https://doi.org/10.1097/SCS.0000000000004567. Ribeiro-Rotta RF,...

Abbreviations : Relation between insertion torque ...

Cone beam computed tomography Computed tomographic Digital Imaging and Communications in Medicine Field of view Mean gray values Region of interest

Conclusions : Relation between insertion torque an...

In summary, within the conditions and limitations of this study, the results suggest that bone quality has a significant effect on the primary stability of short implants as measured by insertion torque. Insertion torque had significant correlation with all assessment methods of bone quality. For preoperative CT evaluation of bone quality, mean gray values (optical density) had stronger associatio...

Discussion : Relation between insertion torque and...

The present study also used the same preoperative CT images for visual evaluation of bone quality at the exact implant site, using the axial, coronal, and sagittal sections in a standardized procedure. There was a fairly moderate correlation between CT visual assessment and mean gray values, but no statistical difference was found in average mean gray values between the visual classification of bo...

Discussion : Relation between insertion torque and...

In this study, low- and medium-density values (air and a central FOV soft tissue) were used as reference calibration points for image normalization. The use of a reference object in the FOV containing at least two materials of known density could allow for a calibration similar to the use of reference phantoms in quantitative CT, rather than the “standard” automatic normalization function avai...

Discussion : Relation between insertion torque and...

This study showed that low bone quality, as assessed by clinical and image methods, is related with low primary stability of 6-mm short implants placed at the posterior region of the maxilla and mandible. Higher insertion torque values were associated with better bone types and higher mean gray values in CT images. Insertion torque had a negative moderate association with bone type categorization ...

Results : Relation between insertion torque and ta...

Descriptive statistics of the sample are shown in Table 1. For statistical analysis, some data were missing: one implant had mobility after surgery and was lost and four CT scans, containing 11 ROIs, were not used for bone quality analysis due to technical problems. As only one case was categorized as bone type 1 by CT visual or by tactile evaluation, the corresponding mean gray values were exclu...

Methods : Relation between insertion torque and ta...

The mean gray value of each rescaled ROI was measured on the three orthogonal planes: axial, coronal, and sagittal, totaling three ROIs per implant site. The average of the rescaled gray values for the three ROIs was computed for each implant site. Data were analyzed by descriptive and inferential statistics using the software XLSTAT version 2018 (Addinsoft SARL, New York, USA), and a two-tailed ...

Methods : Relation between insertion torque and ta...

Axial ROI: Using the reference implant location line, the ROI was defined as the alveolar bone area with a 6-mm width corresponding to 3 mm on each side of the future implant center, including the buccal and lingual cortical layers. Coronal ROI: Area defined by the outer border of the cortical bone with a 6-mm height and a line joining the buccal and lingual cortical layers. Sagittal ROI: A 6â...

Methods : Relation between insertion torque and ta...

The insertion torque was measured using the manual torque wrench (Straumann Dental Implant System®, Waldenburg, Switzerland) (Fig. 1b), according to three categories:  35 N cm. A healing cap was installed, and the suture was made with nylon 5-0 (Fig. 1c). The patients were prescribed with antibiotics (amoxicillin 500 mg, 8/8 h for 7 days), anti-inflammatory drugs (nimesulide 100 mg,...

Methods : Relation between insertion torque and ta...

This study reports cross-sectional, correlational data of a prospective clinical research project [2] approved by the university Institutional Review Board (10/05074). The research protocol followed the precepts of the Declaration of Helsinki and its amendments. All patients signed an informed consent form. A consecutive, non-probabilistic sample consisted of 45 implants placed in 20 patients tre...

Background : Relation between insertion torque and...

Both multislice CT and cone beam CT are used for presurgical assessment of bone density and quality [4,5,6,7,8,9,10,11]. There is a strong correlation between gray values in cone beam CT and Hounsfield units in multislice CT [4, 12,13,14]. The visual inspection of CT sections avoids the superimposition of anatomical structures seen in radiographs; thus, the region of interest in trabecular bone ca...

Background : Relation between insertion torque and...

The early clinical success of short implants can be affected by poor bone quality and low primary stability because implant micromovement can promote the formation of a fibrous capsule during the osseointegration process. It has been reported that the greater the insertion torque, the greater the resistance of the bone-implant interface to the shear forces that tend to rotate the implant [1]. Clin...

Abstract : Relation between insertion torque and t...

This study assessed the relationship between insertion torque and bone quality evaluated during surgery and in preoperative computed tomographic (CT) images analyzed either visually or by rescaled mean gray values (MGVs). The study also tested the correlation between the clinical and radiographic measures of bone quality. The consecutive sample was composed of 45 short implants (4.1 × 6 mm...

Fig. 9. The comparison of two groups at average vo...

Fig. 9. The comparison of two groups at average voxel values for each part. The comparison of voxel values by insertion torque. All specimens were classified into two groups by insertion torque

Fig. 8. The relationship between average voxel val...

Fig. 8. The relationship between average voxel value and insertion torque (averaged over the entire treatment area). The comparison of average voxel value among IT groups. Average voxel value was 384.0 ± 154.6 in the low IT group, 387.7 ± 147.7 in the medium IT group, and 619.2 ± 200.4 in the high IT group Fig. 8. The relationship between average voxel value and insertion torqu...

Fig. 7. The average voxel value between the maxill...

Fig. 7. The average voxel value between the maxilla and mandible. There was no difference between the maxilla (430.9 ± 211.6) and the mandible (475.6 ± 211.5) in the average voxel value. Also, no difference was found in each part Fig. 7. The average voxel value between the maxilla and mandible. There was no difference between the maxilla (430.9 ± 211.6) and the mandible (475.6â...

Fig. 6. The relationship between ISQ and insertion...

Fig. 6. The relationship between ISQ and insertion torque. Percentage of specimens showing ISQ ≥ 73 compared with groups by week. In all groups, a period of rapidly increasing percentages was observed (8–12 weeks in the low IT group, 4–6 weeks in the medium and high IT groups). In the medium and high IT Group, a statistically significant difference was observed between ISQ ≥ 73 a...

Fig. 5. The comparison of ISQ values by the insert...

Fig. 5. The comparison of ISQ values by the insertion torque. Time-lapse migration of ISQ values was compared with IT groups. Each IT group displayed similar migration. A significant difference in The ISQ was found in the low IT group after 8 weeks Fig. 5. The comparison of ISQ values by the insertion torque. Time-lapse migration of ISQ values was compared with IT groups. Each IT group displ...

Fig. 4. The classification of the insertion torque...

Fig. 4. The classification of the insertion torque. All specimens classified into three groups according to insertion torque. Criteria for the classification are shown in the figure and in the “Methods” section Fig. 4. The classification of the insertion torque. All specimens classified into three groups according to insertion torque. Criteria for the classification are shown in the figur...

Fig. 3. The evaluation of the average ISQ. Time-la...

Fig. 3. The evaluation of the average ISQ. Time-lapse migration of average ISQ. Average ISQ of all specimens increased in a time-dependent manner (results indicated by a line). A significant difference was observed by 6 weeks after surgery Fig. 3. The evaluation of the average ISQ. Time-lapse migration of average ISQ. Average ISQ of all specimens increased in a time-dependent manner (results...

Fig. 2. The measurement of the voxel values. A cas...

Fig. 2. The measurement of the voxel values. A case of bone quality diagnosis before treatment. Width and height of the bone were measured to select the proper size of the implant body. The selected implant body was simulated on the bone images as a symbol, and then the voxel value was calculated as described in the “Methods” section Fig. 2. The measurement of the voxel values. A case of ...

Fig. 1. Genesio® Plus implant with Aanchor surfac...

Fig. 1. Genesio® Plus implant with Aanchor surface. Scheme of the dental implant body for the Genesio® Plus implants with Aanchor surface used. a Overview picture of Genesio® Plus implants with Aanchor surface. b Image from scanning electron microscopy. Both pictures were provided by GC Corporation. To obtain osseointegration from an early stage, the dental implant body was treated with sandb...

Table 2 Result of IT and ISQ : Prospective multice...

Number of implants Insertion torque value (N cm) Implant stability quotient value 0 week 2 weeks ...

Table 1 Treatment area and size of implant body : ...

Number of implants Treatment area (FDI) Size of implant (mm) Length Diameter 1 ...

About this article : Prospective multicenter non-r...

Homma, S., Makabe, Y., Sakai, T. et al. Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region. Int J Implant Dent 4, 10 (2018). https://doi.org/10.1186/s40729-018-0122-x Download citation Received: 05 September 2017 Accepted: 25 January 2018 Published: 29 March 2018 DOI: https://doi...

Rights and permissions : Prospective multicenter n...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : Prospective multicenter non-...

This research was conducted in accordance with the Helsinki Declaration of 1964 and subsequent ethical standards, with the approval of Tokyo Dental University and Fukuoka Dental College Ethics Committee (World Medical 2013). The surgeon explained the contents of the research to each patient, who then consented to participate in the present study. All participants consented to publish their inform...

Author information : Prospective multicenter non-r...

Correspondence to Shinya Homma.

Author information : Prospective multicenter non-r...

Department of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Misaki-cho, Chiyoda-ku, Tokyo, 101-0061, Japan Shinya Homma, Yasushi Makabe & Yasutomo Yajima Section of Oral Implantology, Department of Oral Rehabilitation, Fukuoka Dental College, 2-15-1 Tamura, Sawara-ku, Fukuoka-City, Fukuoka, 814-0175, Japan Takuya Sakai, Kenzou Morinaga & Hirofumi Kido Center for Oral ...

References : Prospective multicenter non-randomize...

Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res. 2004;15(5):520–8. Ito Y, Sato D, Yoneda S, Ito D, Kondo H, Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments. Clin Oral Implants Res. 2008;19(1):9–...

References : Prospective multicenter non-randomize...

Boronat López A, Balaguer Martínez J, Lamas Pelayo J, Carrillo García C, Peñarrocha DM. Resonance frequency analysis of dental implant stability during the healing period. Med Oral Patol Oral Cir Bucal. 2008;13(4):E244–7. Gapski R, Wang HL, Mascarenhas P, Lang NP. Critical review of immediate implant loading. Clin Oral Implants Res. 2003;14(5):515–27. Esposito M, Hirsch JM, Lekholm U, Th...

References : Prospective multicenter non-randomize...

Schulte W, Lukas D. The Periotest method. Int Dent J. 1992;42(6):433–40. Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8(3):226–33. Meredith N. Assessment of i...

References : Prospective multicenter non-randomize...

Aparicio C, Rangert B, Sennerby L. Immediate/early loading of dental implants. A report from the Sociedad Española de Implantes World Congress consensus meeting in Barcelona, Spain 2002. Implant Dent Relat Res. 2003;5:57–60. Cochran DL, Moeton D, Weber HP. Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants. Int J Oral Maxillofac ...

Abbreviations : Prospective multicenter non-random...

Cone beam CT Computed tomography Digital Imaging and Communications in Medicine Implant stability quotient Insertion torque Multi-slice CT

Conclusions : Prospective multicenter non-randomiz...

The purpose of this study was to evaluate the relationship between the insertion torque value and the ISQ value at the implant treatment using the current rough-surfaced implant. As a result, no significant relationship was found between the insertion torque value and the ISQ value. Also, it was suggested that the ISQ value was considered to be an important indicator for observing the treatment st...

Discussion : Prospective multicenter non-randomize...

As accurate CT attenuation was not measured due to the lower spatial resolution of CBCT compared with MSCT, a CBCT was recognized as unsuitable for evaluating bone quality. However, several groups have recently reported the potential use of CBCT systems as an apparatus for estimating bone quality. Isoda et al. described a high correlation between voxel values obtained by CBCT and IT of the implant...

Discussion : Prospective multicenter non-randomize...

In this study, we could not find a significant relationship between insertion torque value and ISQ value. However, insertion torque value is an important indicator for predicting the progress of implant treatment, and ISQ value is considered to be an important indicator for observing the treatment state of the implant. Currently, the insertion torque value is used as the major decision index for t...

Discussion : Prospective multicenter non-randomize...

Increases or decreases of ISQ values are explained as follows: The inserted dental implant body is supported by mechanical interdigitating force after surgery, but this interdigitating force will be reduced time-dependently by the effects of osteoclasts activation at the initial stage of the bone remodeling process, then osseointegration will be completed by an increasing contact area between the ...

Discussion : Prospective multicenter non-randomize...

The insertion torque value in this study showed broader (10 to 50 N cm) than the previous publication (Table 2) [22, 32], and the cause of reasons for the difference are as follows: Primary stability may be affected by the bone quantity and bone quality in the treatment area, the micro- and macro-level design of the implant body, and the accuracy of the surgical technique [18, 25]. In this stud...

Discussion : Prospective multicenter non-randomize...

According to the previous literature, the obtaining osseointegration is integral to the intraosseous stability of the implant body during the healing period [24]; moreover, the importance of postoperative assessment of the intraosseous stability of the implant has also been reported [10]. Intraosseous stability of the implant body is evaluated immediately after the implant insertion and during the...

Results : Prospective multicenter non-randomized c...

Average ISQ tended to increase during the healing period in all IT groups (Fig. 5). Average ISQ of the low IT group was 59.81 at 0 week, increasing significantly after ≥ 8 weeks (P 

Results : Prospective multicenter non-randomized c...

A total of 33 implant bodies (8 in the maxilla, 25 in the mandible) were inserted into the 27 participants (11 men, 16 women), with the average age of 54.6 ± 12.2 years (range, 32–78 years). The average IT value was 32.7 ± 9.2 N cm (32.5 ± 11.6 N cm in the maxilla, 32.8 ± 8.5 N cm in the mandible). The diameter of the implant body was 4.4 mm in 20 (60.6%) and 3.8 mm...

Methods : Prospective multicenter non-randomized c...

The CBCT was performed using a 3DX Multi-Image Micro CT FPD 8 system (J. MORITA MFG., Kyoto, Japan) (tube voltage, 80 kV; imaging area, 80 × 80 mm), and voxel values were measured with coDiagnostix™ 9.7 (dental wings, Montreal, Canada). The voxel values were calculated based on CT images for bone quality diagnosis. Voxel values were measured three times at 12 locations covering the mesial...

Methods : Prospective multicenter non-randomized c...

Implant treatment was performed in accordance with the procedure recommended by the manufacturer, without bone augmentation. A healing abutment was connected to the implant bodies after insertion (implant insertion in one stage method). A total of 17 dentists (treatment experience, 5–35 years; average, 11.5 years) performed all implant treatments in this study. All dentists who performed the i...

Methods : Prospective multicenter non-randomized c...

This prospective study was conducted jointly by Tokyo Dental College (Tokyo, Japan) and Fukuoka Dental College (Fukuoka, Japan) from January to December 2015. All study protocols were conducted in accordance with the Declaration of Helsinki [21] and were approved by the ethics committees of Tokyo Dental College (approval #416) and Fukuoka Dental College (approval #213). Participants comprised pat...

Background : Prospective multicenter non-randomize...

The purpose of this study is to evaluate the relationship between IT and ISQ at implant treatment using the current rough surfaced implant. We evaluated the implant treatment sites with implant stability quotient (ISQ) values, IT values, and voxel values. We assumed that there is relevance between the insertion torque value and the ISQ value.

Background : Prospective multicenter non-randomize...

Dental implant treatments have improved in both convenience and predictability with refinements in implant bodies and treatment procedures as compared to about 50 years ago when clinical applications were started. Currently, an implant body surface is treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseointegration and shortening tr...

Abstract : Prospective multicenter non-randomized ...

A current implant body surface was treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseointegration and shortening the treatment period. Various reports have examined the healing period with the use of these implant bodies, but a consensus opinion has not yet been obtained. The purpose of this study is to evaluate the relationship be...

Abstract : Prospective multicenter non-randomized ...

A current implant body surface was treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseointegration and shortening the treatment period. Various reports have examined the healing period with the use of these implant bodies, but a consensus opinion has not yet been obtained. The purpose of this study is to evaluate the relationship be...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7...

Fig. 2. a Radiographic image of a 3.5-mm-wide by 7-mm-length dental implant at the time of its placement at the mandibular left second premolar in a 63-year-old Caucasian female. b Radiographic image of a three-unit fixed partial denture upon its initial placement. The dental implant is the anterior abutment with the prosthesis screw retained to it. The distal abutment is the mandibular left sec...

Fig. 1. a Initial radiograph exposed at abutment i...

Fig. 1. a Initial radiograph exposed at abutment installation on a 5-mm-wide by 7-mm-length dental implant used to help support a removable partial denture for a 71-year-old Caucasian male. b Radiograph of the area taken at 82 months demonstrates good bone stability. c Clinical image of the area 82 months later. Soft tissue remains healthy. The two teeth anterior are in the process of receivin...

Table 5 Resonance frequency analysis : A 1–7 ye...

Time ISQ n Implant insertion 73.6 ± 8.1 86 1–4 weeks ...

Table 4 Implant survival, life table analysis : A ...

Interval Implants Failed Not followed CSR (%) Insertion to 1 year ...

Table 3 Specification of failed implants (three im...

Sex Age Smoker Risk factors Position Implant diameter ...

Table 2 Implant and site-related specifications : ...

  Number Percent Jaw Maxilla 60 69.8 Mandible ...

Table 1 Patient demographics : A 1–7 year retro...

  Number Percent Age (years) 20–29 1 1.3 30–39 ...

About this article : A 1–7 year retrospective f...

Rosen, P.S., Sahlin, H., Seemann, R. et al. A 1–7 year retrospective follow-up on consecutively placed 7-mm-long dental implants with an electrowetted surface. Int J Implant Dent 4, 24 (2018). https://doi.org/10.1186/s40729-018-0136-4 Download citation Received: 08 January 2018 Accepted: 21 May 2018 Published: 23 August 2018 DOI: https://doi.org/10.1186/s40729-018-0136...

Rights and permissions : A 1–7 year retrospecti...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : A 1–7 year retrospective ...

The study was performed in compliance with the Declaration of Helsinki. Data collection was performed in such a manner that subjects could not be identified, and therefore, it was exempt from IRB review according to Federal Regulation 45 CFR 46.101(b). All participants consented to publish their information details through the clinic’s standard patient consent procedure. Also, all images appear...

Author information : A 1–7 year retrospective f...

Clinical Professor of Periodontics, Baltimore College of Dental Surgery, University of Maryland Dental School, Baltimore, MD, USA Paul S. Rosen Private Practice limited to Periodontics and Dental Implants, 907 Floral Vale Boulevard, Yardley, PA, 19067, USA Paul S. Rosen Neoss Ltd, Gothenburg, Sweden Herman Sahlin University Clinic of Craniofacial, Maxillofacial and Oral Surgery, Vienna, Aust...

Availability of data and materials : A 1–7 year...

Due to the ethical and legal responsibility to respect participants’ rights to privacy and to protect their identity, the clinical dataset is not made publicly available.

References : A 1–7 year retrospective follow-up...

Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Survival rates of short (6 mm) micro-rough surface implants: a review of literature and meta-analysis. Clin Oral Implants Res. 2014;25(5):539–45. Chrcanovic BR, Albrektsson T, Wennerberg A. Diabetes and oral implant failure: a systematic review. J Dent Res. 2014;93(9):859–67. Giro G, Chambrone L, Goldstein A, Rodrigues JA,...

References : A 1–7 year retrospective follow-up...

Jemt T, Olsson M, Franke SV. Incidence of first implant failure: a retroprospective study of 27 years of implant operations at one specialist clinic. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e501–10. Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G. Impact of dental implant length on early failure rates: a meta-analysis of observational studies. J Clin Periodontol. 2011;38(9):856...

Abbreviations : A 1–7 year retrospective follow...

Cumulative survival rate Implant stability quotient Insertion torque Odds ratio Resonance frequency analysis Relative risk

Conclusion : A 1–7 year retrospective follow-up...

The current retrospective consecutive case series study provides preliminary data that treatment with 7-mm-length short implants with a hydrophilic electrowetted surface is a reasonable approach in sites with limited vertical bone dimension. It adds to the body of evidence supporting short implant use for compromised sites. The success seen might be attributed to the larger implant diameters that ...

Discussion : A 1–7 year retrospective follow-up...

Thirty-six percent of the implants in the study were placed in extraction sockets. Provided that sufficient initial implant stability is achieved, there should be no additional risk factors compared to implants in healed sites. Studies have shown no difference in marginal bone remodeling between immediately placed and delayed implants [15]. The biggest limitation of the current study is its very ...

Discussion : A 1–7 year retrospective follow-up...

A wide distribution in implant insertion torque (10–50 Ncm) was seen in the study. This reflects the variety of clinical situations in which the implants were placed. Assessments were made by using both the RFA value and the insertion torque as to first whether an implant should have been left to heal in the first place and if so, how this would be best accomplished, i.e., through its submergen...

Discussion : A 1–7 year retrospective follow-up...

This retrospective study is the first to look at short dental implants with a hydrophilic electrowetted surface. The survival data suggest that this treatment is a viable option to care. In a systematic review that identified 13 studies on implants shorter than 10 mm, the CSR from the individual studies ranged from 80 to 100% with a combined CSR of 98.3% after 5 years, 94.8% after 6 years, and ...

Results : A 1–7 year retrospective follow-up on...

The chart review identified 86 placed implants in 75 patients. Table 1 summarizes the patient demographics of the 75 patients. Patients ranged in age from 29 to 88 years with a mean of 61.0 ± 12.5 years. Twenty-seven of the patients were males and 48 were females. Table 2 summarizes the implant and site-related information of the 86 placed implants. Mean insertion torque was 30.1 ± 7...

Methods : A 1–7 year retrospective follow-up on...

Baseline parameters, both patient- and implant-related, as well as follow-up parameters (implant survival, follow-up time, and resonance frequency analysis) were collected from a review of the patient records. The main study parameters (principal outcome parameters) were defined to be implant loss and follow-up time. The cumulative survival rate was estimated. The influence of several factors on ...

Methods : A 1–7 year retrospective follow-up on...

A retrospective study on short 7 mm hydrophilic implants from a single center was conducted in a private practice limited to periodontics and surgical dental implant placements from one of the authors, PSR (Yardley, Pennsylvania, USA). An exhaustive chart review identified 75 patients for analysis that were treated with 86 short (7 mm) implants during a 5-year period (September 1, 2009, to Novem...

Background : A 1–7 year retrospective follow-up...

The aim of this retrospective consecutive case series study was to investigate implant survival rate and analyze possible factors affecting the survival of short implants placed in one surgical practice focused on implantology and periodontology in a temporal cohort.

Background : A 1–7 year retrospective follow-up...

In the past decades, the osseointegration rate of dental implants has dramatically increased, particularly in sites of softer dental bone, which may be attributed to the introduction of moderately roughened surfaces [1, 2]. Moreover, because of this increase in success, clinicians have attempted to push the envelope and place implants into sites that may provide a greater challenge as they wish to...

Abstract : A 1–7 year retrospective follow-up o...

This retrospective consecutive case series study was performed to determinate the survival rate and implant stability of short (7 mm length) dental implants with an electrowetted hydrophilic surface that were in function from 1 to 7 years. A retrospective chart review identified and evaluated 86 consecutively placed 7-mm-long dental implants (ProActive, Neoss Ltd., Harrogate, England) in 75 pat...

Fig. 2. The cumulative survival rates for the diff...

RFs (log rank, p = 0.006) Fig. 2. The cumulative survival rates for the different RF groups revealing a significant difference for patients without any and patients with local and systemic RFs (log rank, p = 0.006)

Fig. 1. On Kaplan-Meier survival estimates, the cu...

Fig. 1. On Kaplan-Meier survival estimates, the cumulative survival rate was 91.5% Fig. 1. On Kaplan-Meier survival estimates, the cumulative survival rate was 91.5%

Table 2 Clinical parameters and reason for implant...

Region Systemic RF Local RF Immediate procedure Bone grafting Time of failure (months...

Table 1 Distribution of patients with local and sy...

Systemic RF No. of implants (n = 31) No. of patients (n = 14) Local RF No. of implants (n = 100) ...

About this article : Retrospective cohort study of...

Saridakis, S.K., Wagner, W. & Noelken, R. Retrospective cohort study of a tapered implant with high primary stability in patients with local and systemic risk factors—7-year data. Int J Implant Dent 4, 41 (2018). https://doi.org/10.1186/s40729-018-0151-5 Download citation Received: 20 May 2018 Accepted: 24 October 2018 Published: 17 December 2018 DOI: https://doi.org/10...

Rights and permissions : Retrospective cohort stud...

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were m...

Ethics declarations : Retrospective cohort study o...

This article contains data obtained during follow-up in a cohort of patients treated with a CE-certified implant in a University Medical Center. Since the product is already approved in accordance with the German Medical Devices Act, no additional ethics approval was not required for treatment. All procedures performed in studies involving human participants were in accordance with the ethical sta...

Author information : Retrospective cohort study of...

Department of Oral and Maxillofacial Surgery – Plastic Surgery, University Medical Center, Johannes Gutenberg University of Mainz, Augustusplatz 2, 55131, Mainz, Germany Sotirios Konstantinos Saridakis, Wilfried Wagner & Robert Noelken Private Practice for Oral Surgery, Lindau/Lake Constance, Germany Robert Noelken You can also search for this author in PubMed Go...

Acknowledgements : Retrospective cohort study of a...

Not applicable The work was supported by the Clinic of Oral and Maxillofacial Surgery, University Medical Center, Mainz. The dataset supporting the conclusions of this article is partially included within the article. The SPSS data can be given on demand of the editor.

References : Retrospective cohort study of a taper...

Schropp L, Isidor F, Kostopoulos L, Wenzel A. Patient experience of, and satisfaction with, delayed-immediate vs delayed single-tooth implant placement. Clin Oral Implants Res. 2004;15:498–503. Download references

References : Retrospective cohort study of a taper...

August M, Chung K, Chang Y, Glowacki J. Influence of estrogen status on endosseous implant osseointegration. J Oral Maxillofac Surg. 2001;59:1285–9. Hultin M, Gustafsson A, Hallstrom H, Johansson LA, Ekfeldt A, Klinge B. Microbiological findings and host response in patients with periimplantitis. Clin Oral Implants Res. 2002;13:349–58. Heitz-Mayfield LJA. Peri-implant diseases: diagnosis and...

References : Retrospective cohort study of a taper...

Chrcanovic BR, Albrektsson T, Wennerberg A. Diabetes and oral implant failure: a systematic review. J Dent Res. 2014;93(9):859–67. Balshi TJ, Wolfinger GJ. Dental implants in the diabetic patient: a retrospective study. Implant Dent. 1999;8:355–9. Fiorellini JP, Chen PK, Nevins M, Nevins ML. A retrospective study of dental implants in diabetic patients. Int J Periodontics Restorative Dent. 2...

References : Retrospective cohort study of a taper...

Kramer FJ, Baethge C, Swennen G, Bremer B, Schwestka-Polly R, Dempf R. Dental implants in patients with orofacial clefts: a long-term follow-up study. Int JOral Maxillofac Surg. 2005;34:715–21. Ortega-Martinez J, Perez-Pascual T, Mareque-Bueno S, Hernandez-Alfaro F, Ferres-Padro E. Immediate implants following tooth extraction. A systemic review. Med Oral Patol Oral Cir Bucal. 2012;17(2):e251â€...

References : Retrospective cohort study of a taper...

U.S. Census Bureau, 2012 Population Estimates and 2014 National Projections. [Zitiert:18.12.2014]. https://www.census.gov/data/tables/2014/demo/popproj/2014-summary-tables.html. Ikebe K, Wada M, Kagawa R, Maeda Y. Is old age a risk factor for dental implants? Jpn Dent Sci Rev. 2009;45:59–64. Hu SC, Lan CE. High-glucose environment disturbs the physiologic functions of keratinocytes: focusing o...

Conclusions : Retrospective cohort study of a tape...

This study was based on the recruitment of a quite heterogeneous group of patients treated with NobelActive implants, for the purpose of investigating the influence of local and systemic risk factors on implant survival and marginal bone levels. It can be considered that the presence of local or systemic risk factors does not influence implant survival whereas the combination of local and systemic...

Discussion : Retrospective cohort study of a taper...

A major weakness of the study is the relative small size of the group with systemic RFs (14 implants by 6 patients) as well as of the group with systematic and local RFs (17 implants by 6 patients). Because of the relative small size of the sample, this study can provide the basis for further investigations based on larger patient samples.

Discussion : Retrospective cohort study of a taper...

The survival rate for 93 implants in 45 patients with no RFs was 94.8%. Moraschini et al. [44] have exhibited in their systematic review, based on 7711 implants, similar SRs with cumulative mean values of 94.6%. Moreover, in the subcohort of our study, by 44 of the above 93, implants were performed immediate procedures (25 immediate implantations, 35 immediate restorations, 16 both of them) so the...

Discussion : Retrospective cohort study of a taper...

In one patient with three implants and long intake of corticosteroids against rheumatoid arthritis (7.5 mg prednisolone per day for at least 2 years), no complication was detected in our study. Long-term use of corticosteroids can also lead to implant failures, according to Wood and Vermilyea [34] by modifying the patient’s response to bacterial infection [35], but at the present time, there i...

Discussion : Retrospective cohort study of a taper...

Most implant studies deal only with local risk factors, although the existence of systemic risk factors plays a significant role to the implant survival. We use the NobelActive dental implant in this study in order to investigate if this promising implant with the special design could achieve better survival rates in difficult situations with several risk factors. The present study revealed no sta...

Results : Retrospective cohort study of a tapered ...

Regarding the implant shoulder level, the average interproximal marginal bone level was − 0.49 ± 0.83 mm (range, 0 to − 3.3 mm) at the mesial aspect and − 0.51 ± 0.82 mm (range, 0 to − 3.9 mm) at the distal aspect of the implants. When the marginal bone level was considered as a function of time, there was no strict correlation between the marginal bone status and th...

Results : Retrospective cohort study of a tapered ...

Ninety-eight patients with 207 implants complied with the treatment protocol attended the follow-up. During the follow-up period, 15 implants failed in 12 patients. Age and gender were not correlated with a lower implant survival. The implant losses occurred in a time range between 0.5 and 39 months following implant placement (mean 7.3 ± 11.1 months). The reasons for implant failure were ...

Material and methods : Retrospective cohort study ...

Subpopulations within the study group (immediate vs. delayed placement) were compared using the Wilcoxon-Mann-Whitney non-parametric U test. The reported p values were two sided. All calculations were carried out using SPSS for Mac, Version 22 (SPSS Inc., Chicago, IL, USA).

Material and methods : Retrospective cohort study ...

Preservation of all alveolar socket walls via longitudinal extraction after periotomy avoiding oro-vestibular luxation. Meticulous cleaning of the extraction site. Placement of rather long implants that allow for a high level of primary stability. Implant dimensions were as follows: implant length 8.5 mm, 24 implants; 10 mm, 6 implants; 11.5 mm, 64 implants; 13 mm, 80 implants; 15 mm, 31 i...

Material and methods : Retrospective cohort study ...

These patients received a total of 207 NobelActive implants (Nobel Biocare, Zurich, Switzerland) placed by two experienced surgeons. Between November 2011 and February 2015, 188 implants were placed in the maxilla, and 19 implants in the mandible. All implant placement procedures were conducted at the Department of Oral and Maxillofacial Surgery of the University Medical Center, Mainz, Germany. Fi...

Material and methods : Retrospective cohort study ...

One hundred and ten patients were invited for follow-up evaluation. All patients were treated in the period from 10/2008 to 02/2015 in the Clinic of Oral and Maxillofacial Surgery, University Medical Center Mainz. Inclusion criteria were as follows: implant placement of a NobelActive implant, study subjects over 18 years old, residual bone dimension in the edentulous region of at least 5 mm in h...

Introduction : Retrospective cohort study of a tap...

Primary stability is a prerequisite for successful osseointegration and remains the most significant factor for the survival of dental implants [16]. Therefore, current research focuses on amelioration of existing augmentation techniques and materials or on the development of new implants with self-tapping properties for improving bone contact as well for increasing primary stability. The aim of ...

Introduction : Retrospective cohort study of a tap...

Based on published demographic data, the median age of the world population constantly increases [1]. This has led to an increase in the number of dental implants inserted in senior individuals with local and systemic risk factors [2]. Nevertheless, despite numerous studies having been conducted on this topic, the results remain controversial, almost 50 years after the first dental implant placem...

Abstract : Retrospective cohort study of a tapered...

This retrospective study examined the mid- to long-term clinical and radiographic performance of a tapered implant in various treatment protocols in patients with local and systemic risk factors (RFs). Two hundred seven NobelActive implants were inserted in 98 patients in the period from 10/2008 to 02/2015. The subdivision of the cohort was defined by local (n = 40), systemic (n = 6), loc...

Table 2 Insertion torque (IT), removal torque (RT)...

Code IT(N•cm) RT(N•cm) ISQ 12S 13.67 (1.88) 11.68 (1.06) 51.40 (2.95) 06D 20.19 (1.61) 17.45 (1.28) 53.77 (2.73) 06S 22.30 (1.78) 20.25 (2.47) 55.66(1.62)

Table 1 Dimensions of implants

Implant code Thread type Pitch (mm) Lead (mm) Lead angle (degree) Total thread length (mm) 12S Single-threaded 1.2 1.2 8.1 64 06D Double-threaded 0.6 1.2 8.1 129 06S Single-threaded 0.6 0.6 4.65 129

Figure 6. Bone debris at the contact interfaces

  Figure 6. Bone debris at the contact interfaces. a Numbers of debris particles. b Number and size of debris particles. Each dot indicates a debris particle, and dashes indicate median particle sizes. Particle sizes: small, < 1000 μm2; medium, 1000–10000 μm2, and large, ≥ 10,000 μm2. c Particle size distribution

Figure 5. Microscopic analysis of contact interfac...

  Figure 5. Microscopic analysis of contact interfaces. Microscopic observations of the artificial bone-implant and number of debris particles. The small arrows in the panel indicate voids in the implant-bone interface

Figure 4. Torque kinetics. Immediately after inser...

  Figure 4. Torque kinetics. Immediately after insertion terminated, the implant was removed using the same load and rotation speed. Torque kinetics were measured during implant insertion (top) and removal (bottom)

Figure 3. Comparison between IT and RT

  Figure 3. Comparison between IT and RT. Maximum IT value was measured when insertion was terminated. Immediately after insertion, the implant was removed, and the RT value was measured when removal commenced

Figure 2. Insertion torque (IT), removal torque (R...

  Figure 2. Insertion torque (IT), removal torque (RT), and implant stability quotient (ISQ)  

Figure 1. Implant code 12S

Figure 1. Implants. Implant code 12S is similar to a commercially available standard single-threaded implant with equal thread pitch and a 1.2-mm lead. The thread length of implant code 06D is doubled by adding the second thread (light blue). The thread length of implant code 06S is doubled by a 50% reduction in pitch and lead angles. Characteristics of each implant are summarized in Table 1 Fi...

References : Effects of implant thread design on p...

References Javed F, Ahmed HB, Crespi R, Romanos GE. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation. Interv Med Appl Sci. 2013;5:162–7. Falco A, Berardini M, Trisi P. Correlation between implant geometry, implant surface, insertion torque, and primary stability: in vitro biomechanical analysis. Int J Oral Maxillofac Implan...

Discussion : Effects of implant thread design on p...

Although bone models composed of a combination of cortical and cancellous bone are also available, this study used a single bone model with a homogeneous density to eliminate any effect of cortical bone and evaluate only the effect of design features on torque and ISQ values. Experimental implant placement using artificial bone models is generally conducted to si...

Discussion : Effects of implant thread design on p...

Clinicians are advised to recognize the risk associated with using a multithreaded implant with a high lead angle, which may compromise primary stability because of greater bone tissue damage despite faster insertion. The question of placement speed warrants further consideration. Indeed, another advantage of double-threaded implants is placement speed. The implantation speed...

Discussion : Effects of implant thread design on p...

Moreover, the IT and RT values of 12S were consistent with those of the standard implant (Straumann) measured in our previous study. Here, the RT value of each implant was lower compared with their respective IT values, consistent with other reports. The IT and RT values of 06S were highest, followed by 06D and 12S. In contrast, the differences between RT and IT values were highest for...

Discussion : Effects of implant thread design on p...

In the artificial bone adjacent to 06D, there were more voids compared with those associated with 06S or 12S, which accounts for the increase in torque. The highest numbers and larger sizes of debris particles were associated with 06D, followed by 0S and 12S, indicating the potential for greater tissue damage. These results likely explain the lower (50%) torque value of 06S compared with tho...

Discussion : Effects of implant thread design on p...

Discussion We show here that increasing thread length and reducing pitch can increase primary implant stability without changing the size of an implant. Compared with the standard single-threaded implant with a 1.2-mm pitch/lead (12S), torque values and ISQ were significantly increased by doubling the thread length by adding the second thread (06D) or by reducing pitch/lead and lead angle o...

Results : Effects of implant thread design on prim...

Results The IT, RT, and ISQ values revealed significant differences among the implants (Table 2). The IT and RT values of 12S were not significantly different compared with published data (IT, 13.13 ± 1.763 N cm; RT, 12.37 ± 1.746 N cm) (Student t test, df = 9, t = 2.91, p < .017). Compared with 12S, the IT and RT values of 06D and 06S were significantly different (147% and 150%, a...

Methods : Effects of implant thread design on prim...

Methods Implants Three types of grade-4 titanium cylindrical nonself-tapping implants (codes 12S, 06D, and 06S) were specially designed and manufactured (Suwa Co., Ltd., Fujiyoshida, Yamanashi, Japan) (Fig. 1 and Table 1). The code 12S single-threaded implant served as a reference. Codes 06D and 06S were designed to double the thread length compared to 12S. Code 06D was a double-threated impla...

Introduction : Effects of implant thread design on...

Introduction Secure primary stability is positively associated with successful long-term implant integration to ensure a successful clinical outcome. Initial implant stability is defined as biomechanical stability upon insertion, which is influenced by factors such as bone quantity and quality, geometry of the implant, surgical technique, and insertion torque (IT). New bone develops around the ...

Effects of implant thread design on primary stabil...

Effects of implant thread design on primary stability—a comparison between single- and double-threaded implants in an artificial bone model   Abstract Background Primary implant stability is essential for osseointegration. To increase stability without changing the implant size, the thread length must be extended by reducing pitch, using a double-threaded implant, or reducing pitch/lead a...

Figure 8. There were moderately significant and po...

    Figure 8. There were moderately significant and positive correlations between the ALP levels and OC levels at all measurements from week 1 to week 12. The OC levels in pg/μg protein were associated with the ALP levels in nM/μg protein at the implant site (a), control site (b), and pooled samples of the control and implant sites (c)

Figure 7. Comparison between biomarker levels & IS...

  Figure 7. Comparison between the trend of the biomarker levels and the trend of the ISQ values over time

Figure 6. There were weakly significant and positi...

  Figure 6. There were weakly significant and positive correlations between the ALP or OC levels and ISQ values at all measurements from week 1 to week 12. At the implant site, the ALP levels in nM/μg protein (a) or the OC levels in pg/μg protein (b) were associated with ISQ values

Figure 5. Change in the median values of the OC le...

  Figure 5. Change in the median values of the OC level over time. In the test group, the OC level continuously increased with time. There was a statistically significant increase in the OC level at 6, 8, 10, and 12 weeks when compared with 1 week (P 

Figure 4. Change in the median values of the ALP l...

  Figure 4. Change in the median values of the ALP level over time. In the test group, the ALP level decreased at 1–4 weeks and then increased at 6, 8, 10, and 12 weeks. There was no statistically significant difference in the ALP level in either the control or the test groups at any measurement

Figure 3. Change in the median values

    Figure 3. Change in the median values of the GCF (control group) and PICF (test group) volume over time. In the test group, the PICF volume continuously decreased with time (a). There were no significant differences in the median values of the crevicular fluid volume in either the control group or the test groups at any measurement (b)

Figure 2. Change in the mean ISQ values over time

  Figure 2. Change in the mean ISQ values over time. There was a statistically significant decrease in the mean ISQ values between 1 and 3 weeks (P 

Figure 1. Timeline of the clinical study

  Figure 1. Timeline of the clinical study. I—implant site, T—contralateral posterior mandibular nonsurgical tooth

Table 5 Crevicular fluid ALP and OC levels

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Median (interquartile range) ALP level  (nM/μg protein)   Tooth (control) 175 (215) 203 (308) 148 (269) 143 (112) 266 (427) 145 (96) 181 (148) 191 (263) 107 (128)   Implant (test) 230 (238) 139 (139) 157 (293) 108 (134) 166 (434) 179 (251) 147 (...

Table 4 Crevicular fluid volume

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Median (interquartile range) CF volume (μl)  Tooth (control) 0.20 (0.23) 0.26 (0.25) 0.19 (0.20) 0.19 (0.50) 0.17 (0.33) 0.18 (0.08) 0.13 (0.24) 0.23 (0.42) 0.20 (0.17)  Implant (test) 0.26 (0.30) 0.25 (0.41) 0.16 (0.21) 0.17 (0.19) 0.18 (0.33) 0.13 (0.14) ...

Table 3 ISQ values according to gender and bone qu...

Time Day 0 1 week 2 weeks 3 weeks 4 weeks 6 weeks 8 weeks 10 weeks 12 weeks Mean ISQ values 77.0 ± 1.32 65.6 ± 2.70a 70.5 ± 2.03a 72.1 ± 1.64a 74.2 ± 1.65 76.1 ± 1.33 78.1 ± 1.38 78.2 ± 1.32 79.6 ± 1.06 Gender  Male (n = 3) 77.0 ± 0.58 59.7 ± 4.62 71.7 ± 3.24 75.0 ± 1.89 7...

Table 2 Profile of patients

Patient no. Age Sex Positiona Bone qualityb 1 34 Female 46 3 2 38 Female 36 3 3 43 Female 37 3 4 64 Male 46 2 5 30 Female 47 3 6 48 Female 36 2 7 57 Male 36 3 8 28 Female 46 3 9 33 Male 46 2 10 49 Female 46 3

Table 1 Inclusion and exclusion criteria

Inclusion criteria Exclusion criteria Patients aged 25–65 years Presence of periodontal disease or periapical lesions Ability to participate in this study History of bone augmentation at the implant site in the past 6 months No systemic diseases (e.g., diabetes, osteoporosis, hypertension, etc.) History of tooth extraction at the implant site in the past 6 months ...

Reference : Relation between the stability of dent...

References Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155–70. Khongkhunthian P. Implant features. In: Khongkhunthian P, editor. PW Plus Thai Dental Implant. Bangkok: STZ Mospace design; 2015. p. 12. Lacey DL, Timms E, Tan HL, Kelle...

Discussion : Relation between the stability of den...

Regarding the relationship between the ISQ values and ALP or OC levels, although the ISQ values were weakly correlated with the bone markers (r = 0.226 for ALP level and r = 0.245 for OC level, P = 0.05), there were significant and positive correlations between the ISQ values and ALP or OC levels at all measurements from week 1 to week 12. These results are in harmony with the ...

Discussion : Relation between the stability of den...

That study showed that PICF volume decreased significantly from week 1 to week 3. Alteration of the gingival fluid volume and contents occur according to the condition of the tissues surrounding the teeth. The presence of inflammation increases the gingival fluid volume. Also, changes in peri-implant crevicular fluid contents and volume result from the condition of the peri-implant tis...

Discussion : Relation between the stability of den...

Discussion The results of this study show that, at the time of implantation, the ISQ values ranged between 67.5 and 83. The mean initial ISQ value was 77.0 ± 1.32. These findings are in harmony with those of previous studies. Tallarico et al. (2011) reported that the macro-design of dental implant affects the primary anchorage. They suggested that the high initial ISQ value is a factor...

Results : Relation between the stability of dental...

Results Ten patients, seven females, and three males, aged 42.4 ± 11.99 years (range, 28 to 64 years), with either a first mandibular or second mandibular molar edentulous area, who required a single nonsubmerged implant participated in this study, as shown in Table 2. The implants used for all patients were 10 mm long and 5 mm in diameter. All patients completed the follow-up. None of t...

Methods : Relation between the stability of dental...

The color in the wells changed from blue to yellow. After that, the color solution in each well was measured at 450/540 nm within 30 min. The OC level in each sample was calculated from a standard curve and normalized by total protein. The level of the ALP activity was measured by colorimetric analysis. Briefly, 80 μl of sample solution were added into each well of a 96-well microplate, and t...

Methods : Relation between the stability of dental...

  Sample preparation and analysis GCF/PICF in the Periopaper strip was eluted by adding 320 μl quantity of phosphate-buffered saline (PBS) into the sample tube and incubated at 4 °C, overnight. The eluted protein solution from each gingival fluid sample was used for the biochemical analysis. Total protein in the gingival fluid sample was measured by the Bradford analysis. Briefly, a 10 μl...

Methods : Relation between the stability of dental...

  RFA assessments At implant placement and after 1, 2, 3, 4, 6, 8, 10, and 12 weeks, RFA assessments were performed using the Osstell® ISQ (Integration Diagnostics AB, Goteborg, Sweden) according to the manufacturer’s instructions. A Smartpeg™ (type 47) (Integration Diagnostics AB) was screwed to the implant using a Smartpeg mount. After Smartpeg mount removal, the RFA assessment was perf...

Methods : Relation between the stability of dental...

Methods The study is a prospective clinical study during the 3-month healing period of implant. The study was approved by the Human Experimentation Committee, Faculty of Dentistry, Chiang Mai University. The study outline is shown in Fig. 1. Patients Ten patients, who were partially edentulous in the mandibular posterior region for whom a single nonsubmerged implant was planned, participated ...

Background : Relation between the stability of den...

The second phenomenon is contact osteogenesis, in which bone formation takes place from the implant surface toward the local bone. This osteogenesis consists of the early phase of osteogenic cell migration, osteoconduction, and de novo bone formation. The de novo bone formation at a solid surface has four stages. The first stage is secretion of the two noncollagenous proteins, osteopontin, and bon...

Background : Relation between the stability of den...

Background Dental implants have shown a high success rate for rehabilitation of edentulous patients if certain conditions are met during treatment. Nevertheless, the risk of failure remains difficult to predict. The achievement of osseointegration depends on many factors, such as a suitable host, biocompatible materials, careful surgery, and an appropriate healing time. The primary stability c...

Relation between the stability of dental implants ...

Relation between the stability of dental implants and two biological markers during the healing period: a prospective clinical study Abstract Objectives The purposes of this study were to examine the correlation between the stability of dental implants and bone formation markers during the healing period and to monitor the stability of dental implants using the resonance frequency analysis (R...

Table 2 Outcome success criteria

Implant success Clinically immobile when tested manually and/or with RFA (minimum ISQ = 65) Absence of peri-implant radiolucency present on an undistorted radiograph Absence of unresolved pain, discomfort, infection or neuropathy, or peri-implant soft tissue complications attributable to the implant Implant placement that does not preclude delivery of a prosthetic crown w...

Figure 3. Mean bone loss at 6 months and 1 year

Figure 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 months was 0.2981 and at 1 year 0.6613 Figure 3. Mean bone loss at 6 months and 1 year. Mean bone loss distribution charts at 6 months and 1 year present no statistically significant difference. p value at 6 month...

Figure 2. ISQ values at placement, 6 weeks, 6 mont...

  Figure 2. ISQ values at placement, 6 weeks, 6 months, and 1 year. Mean and standard deviation of ISQ values taken at placement, 6 weeks, 6 months, and 1 year is presented. No statistical significant difference was determined between ISQ values at all time points. (p 

Table 1 Patient selection criteria

Inclusion Male or female At least 18 years old Healthy enough to undergo routine implant surgery and subsequent dental treatment Partially edentulous requiring single dental implants in the maxilla Adequate volume of native or grafted bone to accommodate dental implants at least 8 mm long No active infections Physically, emotionally, and financially able to u...

Figure 1. Implant design

  Figure 1. Implant design. The OSPTX and OSP implants are manufactured from high-grade commercially pure titanium with surface roughness produced via a fluoride treatment process. The OSP implant is a screw-shaped self-tapping implant. The diameter used in this study was 4.0 mm. The implant length used in this study was 8 mm. The OSPTX implant has the same features as the OSP except the apex ...

Discussion : Comparative evaluation of the stabili...

Discussion Augmentation of the maxillary sinus prior to dental implant placement is routinely performed in order to help patients restore their maxillary posterior dentition. Unfortunately, not all patients are candidates for this procedure due to either health, personal, or financial concerns. An alternative treatment without the need for a sinus elevation procedure is the use of a shorter...

Results : Comparative evaluation of the stability ...

Results Overall implant survival rate was 93.3%. Two implants failed, one implant in group A (OSPTXSoft) and one in group B (OSPTXStd). Both implant failures occurred at the time of uncovery (at 6 weeks) and prior to loading of the implants and were attributed to lack of integration. With the exception of these two failed implants, there was 100% success for all remaining implants using the par...

Methods : Comparative evaluation of the stability ...

Methods Following proper approval by the LSUHSC Institution Review Board (LSUNO IRB#7438), 27 (30 implant sites) systemically healthy patients at least 18 years old were enrolled in the study and randomly divided into three groups as follows (inclusion and exclusion criteria are described in detail in Table 1): Group A received 10 OSPTX implants using the soft bone surgical protocol (OSPT...

Background : Comparative evaluation of the stabili...

To avoid invasive sinus augmentation procedures, implants have been designed in shorter lengths such as 8 mm. To further enhance short implant primary stability, a tapered design has been developed which has been proven to provide greater initial stability. Implant stability can be evaluated by different measures such as torque at the time of implant placement, resistance to reverse torque, and re...

Background : Comparative evaluation of the stabili...

Background Dental implants are now a widely accepted treatment option for the replacement of missing teeth. The therapeutic goal of dental implants is to support restorations that replace single or multiple missing teeth so as to provide patient comfort, function, and esthetics as well as assist in the ongoing maintenance of remaining intraoral and perioral structures. However, anatomic limitat...

Comparative evaluation of the stability of two dif...

Abstract Background The purpose of this study was to compare a parallel wall design implant to a tapered apex design implant when placed in the posterior maxilla using two different surgical protocols. Methods Twenty-seven patients (30 implants) were divided into three groups. All implants were 4 mm wide in diameter and 8 mm long. Group A received 10 tapered implants (OSPTX) (Astra Tech O...

Figure 5. Torque-time curves of the MK3 and MK4

  Figure 5. Torque-time curves of the MK3 and MK4. a Insertion torque. b Removal torque

Figure 4. Torque-time curves of the TE. a Insertio...

Figure 4. Torque-time curves of the TE. a Insertion torque. b Removal torque

Figure 3. Torque-time curves of the BL. a Inserti...

  Figure 3. Torque-time curves of the BL. a Insertion torque. b Removal torque  

Figure 2. Torque-time curves of the ST. a Insert...

  Figure 2. Torque-time curves of the ST. a Insertion torque. b Removal torque

Figure 1. Compressed longitudinally to one third f...

Figure 1. Compressed longitudinally to one third for characteristics of implant design. ST Straumann standard implant, MK3 Nobel Biocare MKIII, BL Straumann bone level implant, TE Straumann tapered effect implant, MK4 Nobel Biocare MKIV. Outer surface of implant (solid line). Inner surface of implant (dotted line) Figure 1. Compressed longitudinally to one third for characteristics of implant d...

Table 3 Torque rise rate of the each area (N ·â...

  Initial area Parallel area Tapered area Platform area ST6 1.42 ± 0.43 0.31 ± 0.14 – – ST8 3.57 ± 1.62 0.35 ± 0.09 – – ST10 2.49 ± 0.81 0.45 ± 0.05 – – BL8 2.16 ± 0.21 0.50 ± 0.08 2.32 ± 0.52 – BL10 1.96 ± 0.49 0.35+0.04 2.45+0.23 – BL12 1.82 ± 0.27 0.33 ±â€...

Table 2 Insertion torque value and removal torque ...

Code Insertion torque Removal torque Effective thread length (ETL) (N · cm) (N · cm) (×π mm) ST6 6.19 ± 0.716 5.95 ± 0.718 11.53 ST8 8.06 ± 1.038 9.09 ± 1.093 15.11 ST10 13.13 ± 1.763 12.37 ± 1.746 21.48 BL8 17.67 ± 1.290 16.67 ± 2.140 20.88 BL10 23.56 ± 1.628 21.99 ± 1.530 31....

Table 1 The type of the implant used for experimen...

System Length Pitch Lead Code Manufacturer (mm) (mm) (mm) Standard RN 6, 8, 10 1.2 1.2 ST Straumann Bone Level RC 8, 10, 12 0.8 0.8 BL Straumann Tapered Effect RN 10 0.8 0.8 TE Straumann Brånemark MKIII 10 0.6 1.2 MK3 Nobel Biocare Brånemark MKIV 10 0.6 1.2 MK4 Nobel Biocare

Reference : Effect of implant design on primary (...

Abbreviations BL: Bone Level RC IT: insertion torque value MK3: Brånemark MKIII MK4: Brånemark MKIV RT: removal torque value ST: Standard RN TE: Tapered Effect RN References Friberg B, Sennerby L, Roos J, Johansson P, Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography. An...

Discussion : Effect of implant design on primary ...

Influence of cortical bone The reason why a simulation test for only cancellous bone without cortical bone was performed in the present study has already been described. It was reported that bone density and the ratio of cortical bone and cancellous bone have influence on the primary stability of an implant and that higher primary stability is achieved with thread, even at the slightest lev...

Discussion : Effect of implant design on primary ...

Although the removal torque curves measured in the present study had similar shapes to one another, they were divided into two groups upon detailed observation, comprising a group of ST with parallel only, and a group of BL, TE, MK3, and MK4 having tapers and platforms. Since the thread contacts the artificial bone sequentially at the time of insertion, the torque curves showed the character...

Discussion : Effect of implant design on primary ...

This indicates that the friction at the time of rotating and pressing is greater than that at the time of rotating and cutting the bones with a tap and is a reasonable result. In the parallel area, the torque curve was a line with a moderate gradient, and the torque rise rate obtained from the gradient of the line was 0.36 N · cm/s. From this, it is estimated that the torque increase w...

Discussion : Effect of implant design on primary ...

Discussion Insertion torque curve In 2000, O’Sullivan reported torque curves for a prosthetic implant for the first time, and evaluated the characteristics of the tapered type by torque curves obtained by inserting five kinds of implants into the maxillary bone of unembalmed human cadavers. In a subsequent review, Meredith cited six kinds of torque curves when the final osteotomy diamete...

Results : Effect of implant design on primary (2)

For the TE, the lower part of the implant was parallel and the lateral surface and axial surface had the same taper in the cervical region. TE10 in Fig. 4a showed a torque curve with a similar form to BL10 in Fig. 3 and had three kinds of areas. The torque curves for MK3 and MK4 in Fig. 4a had an area in which the torque finally rose suddenly after reaching its critical point and became moderate...

Results : Effect of implant design on primary (1)

Results Insertion torque The insertion torque curve was divided into four regions. The first was the region where the torque rose suddenly immediately after insertion, which was seen in all implant bodies (shown as ① in the figure, and hereinafter called the initial area). The second was the region where the torque rose linearly with a moderate gradient, which was seen in all implant bodie...

Methods : Effect of implant design on primary stab...

Methods Implants The type of implant used for the experiments and the characteristics of its design are shown in Table 1 and Fig. 1, respectively. Figure 1 shows that the implant is compressed longitudinally to one third. The outer surface of the implant is indicated with a solid line, and the inner surface of the implant is indicated with a dotted line. Preparation of an implant socket in ...

Background : Effect of implant design on primary s...

Background Primary stability following implant placement is an essential condition for osseointegration. The primary stability is affected by the implant design, including surface-modifying or implant cavity-forming techniques, as well as by the bone quantity and bone density of the patient. In recent years, the interest of implant manufacturers and clinicians has shifted to the acquisition of ...

Effect of implant design on primary stability usin...

Abstract Background Primary stability following implant placement is essential for osseointegration and is affected by both implant design and bone density. The aim of this study was to compare the relationships between torque-time curves and implant designs in a poor bone quality model. Methods Nine implant designs, with five implants in each category, were compared. A total of 90 implants ...

Figure 5 Postoperative orthopantomogram

  Figure 5 a Postoperative orthopantomogram. b Follow-up orthopantomogram. c Follow-up standard periapical radiogram (implants i42 and i44). d Follow-up standard periapical radiogram (implants i32 and i34)

Figure 4 a–h Prosthetic restauration—follow-u...

  Figure 4 a–h Prosthetic restauration—follow-up examination. Intraoral and perioral views of a rehabilitated female patient. (She asked explicitly only for implantological treatment in the mandible.)  

Figure 3. a Primary implant stability

  Figure 3. a Primary implant stability. The histogram visualises the distribution of the implant stability quotients (ISQ) for both jaws measured by resonance frequency analysis (Osstell AB, Göteborg, Sweden). b Secondary implant stability. The histogram shows the distribution of the implant stability quotients (ISQ) of osseointegrated implants. According to the measurement implant stabil...

Figure 2. Cumulative implant survival over the fol...

  Figure 2. Cumulative implant survival over the follow-up period. The Kaplan-Meyer diagram visualises the analysis of implant survival in the maxilla and in the mandible (log rank test, p = 0.173) over the follow-up period up to 37 months (Table 4)  

Figure 1. a Closed short expandable dental implan...

  Figure 1. a Closed short expandable dental implant (4.1 × 7 mm). The implant-abutment connection is characterised by an internal hexagon for rotation stability, combining the advantages of conical and parallel surfaces to reduce microgaps and micromovement. The microthread concept and platform switching concept are implemented in the implant shoulder to reduce periimplant bone strain. bÂ...

Table 4 Clinical characteristics of the study coho...

Patient Sex Age (years) Implant position (FDI) Indication categorya Bone quality Prosthetic treatment Follow-up (months) Implant failure 1. T. I. F 80 Maxilla 15, 13, 11, 21, 25 (Σ = 5) IIa D4 Telescope 37 n = 1c 2. G. S. F 65 Mandible 34, 32, 42, 44 (Σ = 4) IIIb D1 Ball attachment 34 None 3. S. Sa. F 64 Maxilla 14, 12, 22, 24 (Σ = 4) ...

Table 3 Prosthetic treatment protocol

Type of prosthetic treatment Session Procedure Fixed denture (bridge) 1 Open impression 2 Abutment check, set-up • Titanium abutments • Non-precious metal framework, completely lined • Neighbouring crowns interlocked 3 Check and insertion of the suprastructure • Cementation (ImProv™, Dentegris, Duisburg, Germany) Combined fixed-removable dentur...

Table 2 Surgical treatment protocol

Surgical protocol Bone quality   D1 D2 D3 D4 1. Drilling sequence (splint) Last drill Last drill Second to last drill Second to last drill 2. Condensing preparation – – (Analogue to last drill) Analogue to last drill 3. Implant insertion (maximum torque ≤ 40 N cm) 4. Expansion (maximum torque ≤ 40 N cm) 5. Evaluation of primary ...

Table 1 Patient recruitment

Inclusion criteria Exclusion criteria 1. Adult patients, male and female 1. Comorbidity ASA category ≥ III 2. Partially/totally edentulous patients 2. Pregnancy, bruxism 3. Alveolar process atrophy Cawood et Howell category ≥ IV 3. Smoking ≥ 10 cigarettes/day 4. Minimum vertical bone height of 7–9 mm for placement of short implants (5–7-mm length)...

Discussion : Novel expandable short dental implant...

Based on an earlier animal histologic study, as well as a clinical up-to-40-month study, which referred to comparable apically expandable implants, authors did not report any periapical inflammatory complications. To eliminate the potential risk of deep intrabony microleakage, it is questionable whether equal biomechanical stability values can be achieved only by the macroth...

Discussion : Novel expandable short dental implant...

In relation to the results by McCullough and Klokkevold, who found that the macrothread design appears to play a positive role in implant stability in the early healing period, this can also be assumed for the employed implant system. Additionally, with regard to the results by Marković and co-authors, a critical stability drop down due to bone remodeling after bone condensing (impla...

Discussion : Novel expandable short dental implant...

The expansion procedure presents an additional bicortical anchorage in the oro-vestibular direction. In hard bone, this might be a disadvantage and lead to asymmetrical expansion. Manufacturers’ recommendations for hard bone should be strongly considered. Regarding resonance frequency analysis, the values are related to bone quality and quantity as well as the exposed impl...

Discussion : Novel expandable short dental implant...

Several investigators analysed the preferred indications of short dental implants in the posterior mandible or maxilla and outlined the cost efficiency compared to additional vertical augmentations. In the present trial, we used a new short implant in both jaws and nearly all possible indication categories were represented, which proves the broad versatility (Table 4). In our study, two imp...

Discussion : Novel expandable short dental implant...

Discussion Recent literature has shown that short implants have achieved growing acceptance in the field of oral implantology. Since the last years, concern has decreased about the length of endosseous implants; it should be noted that all extraoral screw implants are short implants. Nevertheless, there are local physiological and biomechanical differences regarding long-term stability. Th...

Results : Novel expandable short dental implants (...

Results The first results of this longitudinal study include data from 9 patients with an average age of 57 years (range from 44 to 80) in whom 30 implants were inserted (maxilla n = 15, mandible n = 15). All 30 implants in the 9 patients could be inserted without intraoperative problems. Based on intraoperative and radiological findings, the bone quality was assessed...

Material & methods : Novel expandable short dental...

Surgical and prosthetic protocol Planning of the implantological treatment followed usual clinical and radiological examination and, concerning the position and number of implants, the recommended categories from the German consensus conference. The drilling sequence, condensing preparation (where necessary) and manual implant insertion as well as expansion are described in detail...

Material & methods : Novel expandable short dental...

Material and methods Study population and measures The study was designed as a prospective monocentric longitudinal cohort study according to the STROBE criteria. The participants of this study were recruited at the university hospital of Martin Luther University Halle-Wittenberg, Department of Oral and Plastic Maxillofacial Surgery, implantological consultation from 2014 (June...

Introduction : Novel expandable short dental impla...

... the diameter of an implant has greater influence on primary stability than implant length. Based on in vitro analysis, they concluded additionally that especially in patients with poor bone quality, a variation of implant dimensions is expected to lead to a significant increase of primary stability. Furthermore, stress distribution on short implants is affected by the bone-to-...

Introduction : Novel expandable short dental impla...

Introduction Endosseous implants have been established over several decades. The evaluation of treatment results under biomechanical, physiological, psychological, social and economic aspects has been well documented. Furthermore, patient-based outcomes reveal a predictable gain in oral health-related quality of life. Especially in patients with limited vertical bone height, process of treatme...

Novel expandable short dental implants with reduce...

Novel expandable short dental implants in situations with reduced vertical bone height—technical note and first results   Abstract Purpose Short implants often have the disadvantage of reduced primary stability. The present study was conducted to evaluate the feasibility and safety of a new expandable short dental implant system intended to increase primary stability. Methods As a “pr...

Table 2 Result of IT and ISQ

Number of implants Insertion torque value (N cm) Implant stability quotient value 0 week 2 weeks 4 weeks 6 weeks 8 weeks 12 weeks 1 25 33.0 75.0 77.0 78.3 79.7 77.0 2 40 68.0 70.3 70.0 72.0 75.7 75.3 3 40 78.3 77.0 78.0 78.7 80.0 80.0 4 35 74.0 43.0 61.0 73.0 75.7 80.0 5 45 85.3 85.7 84.0 83.3 84.0 83.0 6...

Table 1 Treatment area and size of implant body

Number of implants Treatment area (FDI) Size of implant (mm) Length Diameter 1 14 10 3.8 2 14 10 3.8 3 14 10 3.8 4 16 8 3.8 5 16 10 4.4 6 16 8 4.4 7 16 8 4.4 8 17 10 4.4 9 36 10 3.8 10 36 10 4.4 11 36 8 3.8 12 36 10 3.8 13 36 12 4.4 14 36 10 4.4 15 36 10 4.4 ...

Figure 9. The comparison of two groups at average ...

Figure 9. The comparison of two groups at average voxel values for each part. The comparison of voxel values by insertion torque. All specimens were classified into two groups by insertion torque

Figure 8. The relationship between average voxel v...

  Figure 8. The relationship between average voxel value and insertion torque (averaged over the entire treatment area). The comparison of average voxel value among IT groups. Average voxel value was 384.0 ± 154.6 in the low IT group, 387.7 ± 147.7 in the medium IT group, and 619.2 ± 200.4 in the high IT group

Figure 7. The average voxel value between the maxi...

  Figure 7. The average voxel value between the maxilla and mandible. There was no difference between the maxilla (430.9 ± 211.6) and the mandible (475.6 ± 211.5) in the average voxel value. Also, no difference was found in each part

Figure 6. The relationship between ISQ and inserti...

    Figure 6. The relationship between ISQ and insertion torque. Percentage of specimens showing ISQ ≥ 73 compared with groups by week. In all groups, a period of rapidly increasing percentages was observed (8–12 weeks in the low IT group, 4–6 weeks in the medium and high IT groups). In the medium and high IT Group, a statistically significant difference was observed between ISQ â‰...

Figure 5. The comparison of ISQ values by the inse...

  Figure 5. The comparison of ISQ values by the insertion torque. Time-lapse migration of ISQ values was compared with IT groups. Each IT group displayed similar migration. A significant difference in The ISQ was found in the low IT group after 8 weeks  

Figure 4. The classification of the insertion torq...

  Figure 4. The classification of the insertion torque. All specimens classified into three groups according to insertion torque. Criteria for the classification are shown in the figure and in the “Methods” section

Figure 3. The evaluation of the average ISQ. Time-...

    Figure 3. The evaluation of the average ISQ. Time-lapse migration of average ISQ. Average ISQ of all specimens increased in a time-dependent manner (results indicated by a line). A significant difference was observed by 6 weeks after surgery

Figure 2. The measurement of the voxel values

  Figure 2. The measurement of the voxel values. A case of bone quality diagnosis before treatment. Width and height of the bone were measured to select the proper size of the implant body. The selected implant body was simulated on the bone images as a symbol, and then the voxel value was calculated as described in the "Method" section

Figure 1. Genesio® Plus implant with Aanchor surf...

  Figure 1. Genesio® Plus implant with Aanchor surface. Scheme of the dental implant body for the Genesio® Plus implants with Aanchor surface used. a Overview picture of Genesio® Plus implants with Aanchor surface. b Image from scanning electron microscopy. Both pictures were provided by GC Corporation. To obtain osseointegration from an early stage, the dental implant body was treated...

Discussion : intraosseous stability and healing pe...

According to the measurement of the average voxel values in this study, a significant difference was seen between the high IT group and the low/medium IT group, but no significant difference was found between the low and medium IT groups (Fig. 7). Specimens showing IT ≥ 40 N cm were thought to have a good bone quality, and voxel values at each part of the implant (neck, middle apex) were...

Discussion : intraosseous stability and healing pe...

A bone quality of the treated area may affect primary stability as described above, preoperative analysis of bone quality is important for clarifying the primary stability of dental implants. This study analyzed bone quality using voxel values obtained using Digital Imaging and Communications in Medicine (DICOM) data from CBCT. According to the result of that analysis, it was...

Discussion : intraosseous stability and healing pe...

A significant difference was observed between 0 and ≥ 8 weeks (Fig. 5). The ISQ did not change significantly during the experimental period in the medium or high IT groups, but the percentage of high ISQ (≥ 73) specimens was significantly higher at 4 to 6 weeks compared to other time periods in both groups (Figs. 5 and 6). The results in this study suggest that if the...

Discussion : intraosseous stability and healing pe...

Other studies have suggested that ISQ immediately after implant insertion should be about 60, with ISQ subsequently decreasing over weeks 0–4 and increasing over weeks 4–8 after surgery. ISQ values 57–70 may indicate that intraosseous stability of the implant body is constant. Increases or decreases of ISQ values are explained as follows: The inserted dental implant bo...

Discussion : intraosseous stability and healing pe...

The insertion torque value in this study showed broader (10 to 50 N cm) than the previous publication (Table 2), and the cause of reasons for the difference are as follows: Primary stability may be affected by the bone quantity and bone quality in the treatment area, the micro- and macro-level design of the implant body, and the accuracy of the surgical technique. In this ...

Discussion : intraosseous stability and healing pe...

Discussion According to the previous literature, the obtaining osseointegration is integral to the intraosseous stability of the implant body during the healing period; moreover, the importance of postoperative assessment of the intraosseous stability of the implant has also been reported. Intraosseous stability of the implant body is evaluated immediately after the implant ...

Results : intraosseous stability and healing perio...

Average ISQ tended to increase during the healing period in all IT groups (Fig. 5). Average ISQ of the low IT group was 59.81 at 0 week, increasing significantly after ≥ 8 weeks (P 

Methods : Prospective multicenter non-randomized c...

Methods Research design and study participants This prospective study was conducted jointly by Tokyo Dental College (Tokyo, Japan) and Fukuoka Dental College (Fukuoka, Japan) from January to December 2015. All study protocols were conducted in accordance with the Declaration of Helsinki and were approved by the ethics committees of Tokyo Dental College (approval #416) and Fukuoka Dental Colle...

Results : intraosseous stability and healing perio...

Results Study overview A total of 33 implant bodies (8 in the maxilla, 25 in the mandible) were inserted into the 27 participants (11 men, 16 women), with the average age of 54.6 ± 12.2 years (range, 32–78 years). The average IT value was 32.7 ± 9.2 N cm (32.5 ± 11.6 N cm in the maxilla, 32.8 ± 8.5 N cm in the mandible). The diameter of the implant body wa...

Methods : Prospective multicenter non-randomized c...

Methods Research design and study participants This prospective study was conducted jointly by Tokyo Dental College (Tokyo, Japan) and Fukuoka Dental College (Fukuoka, Japan) from January to December 2015. All study protocols were conducted in accordance with the Declaration of Helsinki and were approved by the ethics committees of Tokyo Dental College (approval #416) and Fuku...

Background : Prospective multicenter non-randomize...

Background Dental implant treatments have improved in both convenience and predictability with refinements in implant bodies and treatment procedures as compared to about 50 years ago when clinical applications were started. Currently, an implant body surface is treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseo...

Prospective multicenter non-randomized controlled ...

Abstract Background A current implant body surface was treated with “rough processing” by sandblasting and acid etching for the purposes of obtaining more reliable osseointegration and shortening the treatment period. Various reports have examined the healing period with the use of these implant bodies, but a consensus opinion has not yet been obtained. The purpose of this study is to eval...

Figure 6. Bone debris at the contact interfaces.

    Figure 6. Bone debris at the contact interfaces. a Numbers of debris particles. b Number and size of debris particles. Each dot indicates a debris particle, and dashes indicate median particle sizes. Particle sizes: small, < 1000 μm2; medium, 1000–10000 μm2, and large, ≥ 10,000 μm2. c Particle size distribution

Figure 5. Microscopic analysis of contact interfac...

  Figure 5. Microscopic analysis of contact interfaces. Microscopic observations of the artificial bone-implant and number of debris particles. The small arrows in the panel indicate voids in the implant-bone interface

Figure 4. Torque kinetics

  Figure 4. Torque kinetics. Immediately after insertion terminated, the implant was removed using the same load and rotation speed. Torque kinetics were measured during implant insertion (top) and removal (bottom)

Figure 2. Insertion torque (IT), removal torque (R...

  Figure 2. Insertion torque (IT), removal torque (RT), and implant stability quotient (ISQ)  

Figure 1. Implant code 12S is similar to a commerc...

  Table 2. Implants. Implant code 12S is similar to a commercially available standard single-threaded implant with equal thread pitch and a 1.2-mm lead. The thread length of implant code 06D is doubled by adding the second thread (light blue). The thread length of implant code 06S is doubled by a 50% reduction in pitch and lead angles. Characteristics of each implant are summarized in Table 1....

Table 2 Insertion torque (IT), removal torque (RT)...

Code IT(N•cm) RT(N•cm) ISQ 12S 13.67 (1.88) 11.68 (1.06) 51.40 (2.95) 06D 20.19 (1.61) 17.45 (1.28) 53.77 (2.73) 06S 22.30 (1.78) 20.25 (2.47) 55.66(1.62)

Table 1 Dimensions of implants

Implant code Thread type Pitch (mm) Lead (mm) Lead angle (degree) Total thread length (mm) 12S Single-threaded 1.2 1.2 8.1 64 06D Double-threaded 0.6 1.2 8.1 129 06S Single-threaded 0.6 0.6 4.65 129

Discussion : Effects of implant thread design on p...

The question of placement speed warrants further consideration. Indeed, another advantage of double-threaded implants is placement speed. The implantation speed of 06D was twice that of 06S, and implantation was completed twice as fast. Nevertheless, while plastic bottles and emergency valves have double-threaded screws for faster opening and closing, the effect...

Discussion : Effects of implant thread design on p...

Here, the RT value of each implant was lower compared with their respective IT values, consistent with other reports. The IT and RT values of 06S were highest, followed by 06D and 12S. In contrast, the differences between RT and IT values were highest for 12S, followed by 06D, and in 06S. We reported that the RT decreased more than IT. Thus, 06S had the lowest rate of decline (IT...

Discussion : Effects of implant thread design on p...

In the artificial bone adjacent to 06D, there were more voids compared with those associated with 06S or 12S, which accounts for the increase in torque. The highest numbers and larger sizes of debris particles were associated with 06D, followed by 0S and 12S, indicating the potential for greater tissue damage. These results likely explain the lower (50%) torque value of 06S compared wi...

Discussion : Effects of implant thread design on p...

In the artificial bone adjacent to 06D, there were more voids compared with those associated with 06S or 12S, which accounts for the increase in torque. The highest numbers and larger sizes of debris particles were associated with 06D, followed by 0S and 12S, indicating the potential for greater tissue damage. These results likely explain the lower (50%) torque value of 06S compared wi...

Discussion : Effects of implant thread design on p...

Discussion We show here that increasing thread length and reducing pitch can increase primary implant stability without changing the size of an implant. Compared with the standard single-threaded implant with a 1.2-mm pitch/lead (12S), torque values and ISQ were significantly increased by doubling the thread length by adding the second thread (06D) or by reducing pitch/lead and lead angle o...

Results : Effects of implant thread design on prim...

Results The IT, RT, and ISQ values revealed significant differences among the implants (Table 2). The IT and RT values of 12S were not significantly different compared with published data (IT, 13.13 ± 1.763 N cm; RT, 12.37 ± 1.746 N cm) (Student t test, df = 9, t = 2.91, p < .017). Compared with 12S, the IT and RT values of 06D and 06S were significantly different (147% and 150%, a...

Methods : Effects of implant thread design on prim...

Implants Three types of grade-4 titanium cylindrical nonself-tapping implants (codes 12S, 06D, and 06S) were specially designed and manufactured (Suwa Co., Ltd., Fujiyoshida, Yamanashi, Japan) (Fig. 1 and Table 1). The code 12S single-threaded implant served as a reference. Codes 06D and 06S were designed to double the thread length compared to 12S. Code 06D was a double-threated implant with t...

Effects of implant thread design on primary stabil...

Unfortunately, the effects of double- or triple-threaded implants on primary stability are known for only a few procedures, such as finite element analysis. An excessive lead angle for these implants may jeopardize their ability to sustain axial load despite faster insertion. Further, when micromotion is compared among implants with different lead angles with the same thread pitch, single-threaded...

Effects of implant thread design on primary stabil...

Introduction Secure primary stability is positively associated with successful long-term implant integration to ensure a successful clinical outcome. Initial implant stability is defined as biomechanical stability upon insertion, which is influenced by factors such as bone quantity and quality, geometry of the implant, surgical technique, and insertion torque (IT). New bone develops around the ...

Effects of implant thread design on primary stabil...

Abstract Background Primary implant stability is essential for osseointegration. To increase stability without changing the implant size, the thread length must be extended by reducing pitch, using a double-threaded implant, or reducing pitch/lead and lead angle to half that of a single-threaded implant. Materials and methods We tested the stabilities of these configurations using artificial...

Figure 3. Comparison of standard and over-dimensio...

  Figure 3. Comparison of standard and over-dimensioned protocol. The figure displayed shows the comparison between standard and over-dimensioned protocol. a Displays the measurements obtained by RFA. The unit is ISQ with a range of 0 to 100 (minimum to maximum stability). b Displays the results obtained by the torque in and c by the torque out test. Although, there was no statistically s...

Figure 2. Over-dimensioned protocol

  Figure 2. Over-dimensioned protocol. The over-dimensioned protocol was conducted by a final drill of 1 mm narrower than the implant diameter. The final drill for implants of 3.3. mm was 3.2 mm and of implants measuring 3.75 mm, it was 3.65 mm. Within this study, an over-dimensioned protocol was defined as a final drill larger than recommended by the company, which is in this case 4 o...

Figure 1. Implant types and drilling protocol

  Figure 1. Standard protocol. This figure shows the implant types and drilling protocol used within this study. Standard protocol was conducted by a final drill of 2.80 mm for 3.3 mm implants, 3.20 mm for 3.75 mm implants, and 3.65 mm for 4.2 mm implants. Permissions for reproducing the figures were received from HI-TEC IMPLANTS LTD. Source: Product Catalogue 12th Edition [40]

Table 3 Comparison of implant diameter

  3.3 mm 3.75 mm 4.2 mm Mean (SD) CI Mean (SD) CI Mean (SD) CI ISQ 66.33 (4.59) 63.79–68.88 69.00 (5.98) 64.72–73.28 69.87 (8.88) 64.94–74.78 IT (Ncm) 102.65 (28.42) 86.91–118.39 90.97 (27.54) 71.27–110.67 78.19 (33.28) 59.76–96.62 TO (Ncm) 94.54 (29.09) 78.43–110.65 81.28 (28.89) 60.67–101.88 100.86 (36....

Table 4 Comparison of implant length

  8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm Mean (SD) CI Mean (SD) CI Mean (SD) CI Mean (SD) CI Mean (SD) CI ISQ 65.5 (8.40) 58.48–72.52 73.17 (3.60) 69.39–76.95 67.11 (6.09) 62.43–71.79 66.15 (8.15) 59.43–73.07 70.67 (4.97) 66.84–74.49 IT (Ncm) 98.23 (18.56) 82.71–113.74 99.49 (43.73) 53.60–145.48 101.02 (36.80) 72.74–...

Table 2 Comparison of manual and machine-driven in...

  Insertion mode — manual insertion Insertion mode — machine-driven insertion   n Mean (SD) CI n Mean (SD) CI ISQ 45 68.33 (6.83) 66.14–70.51 45 70.25 (5.52) 68.38–72.12 IT (Ncm) 45 90.56 (31.27) 80.56–100.56 45 83.94 (31.81) 73.17–94.7 TO (Ncm) 45 93.59 (32.3) 83.27–103.92 45 89.80 (37.32) 77.18–102.43 ISQ impla...

Table 1 Comparison of standard and over-dimensione...

Drilling sequence — standard protocol Drilling sequence — over-dimensioned protocol   n Mean (SD) CI n Mean (SD) CI ISQ 45 68.33 (6.83) 66.14–70.51 30 68.5 (8.82) 65.08–71.92 IT (Ncm) 45 90.56 (31.27) 80.56–100.56 30 63.74 (48.61) 44.89–82.59 TO (Ncm) 45 93.59 (32.3) 83.27–103.92 30 58.35 (40.43) 42.67–74.02 ISQ im...

Discussion : Implant primary stability depending o...

Contrary to the research hypothesis, there was no difference in primary stability between manually and machine-driven inserted implants. To date, little is known about the influence of the insertion mode on the dental implant primary stability. Novsak et al. assumed a better primary stability in implants inserted manually and suspected that this behavior was related to a higher tac...

Discussion : Implant primary stability depending o...

However, caution is recommended when using under-dimensioned drilling protocols: although high insertion torques ensure a greater initial implant stability and prevent adverse micromotions under loading, the induced over-compression could jeopardize the healing process. In addition, high stress is known to alter angiogenesis and impair new vessel formations, to induce local hypoxia and n...

Discussion : Implant primary stability depending o...

Discussion This study was performed in order to investigate changes in primary stability within an experimental setup of different insertion protocols and insertion modes. In order to obtain a high level of diagnostic certainty, three different methods for measurement of primary stability were recorded. As a secondary outcome parameter, potential differences between implants of different le...

Results : Implant primary stability depending on p...

Results Drilling protocol: standard versus over-dimensioned No statistically significant difference in RFA could be measured (Cohen’s d = − 0.022, effect size r = 0.011, p = 0.260), whereas IT values were significantly higher in implants inserted via SP (90.56 ± 31.27 Ncm) in comparison with the ODP (63.74 ± 48.61 Ncm, p = 0.002; Cohen’s d = 0.656, effect size r = 0.312). T...

Methods : Implant primary stability depending on p...

Preparation protocol for oversized osteotomies (ODP) This protocol repeated the steps of the standard protocol but then added a larger final drill. For the 3.3-mm implants, the final drill size was 3.2 mm; for the 3.75-mm implants, the final drill size was 3.65 mm (Fig. 2). RFA To analyze the data, an Osstell® SmartPeg threaded transducer (implant diameter 3.3 and 3.75 mm: SmartPeg Type ...

Methods : Implant primary stability depending on p...

Methods Bone specimens Twenty mandibles from fresh porcine cadavers were obtained from a local slaughterhouse. The animals did not show any macroscopic signs of any pathologic bone conditions. After removal of the surrounding soft tissue, the surfaces of the bone samples were thoroughly cleaned. Each sample was checked macroscopically for irregularities and a minimum thickness of 20 mm at th...

Background : Implant primary stability depending o...

Analyzing those, a decrease in primary and an increase in secondary stability with a shorter healing period for implants became apparent. Kim et al. compared the effect of oversized drilling sockets regarding bone-to-implant contact and bone density after 4 and 8 weeks in an in vivo dog model. They used a final drill of 4.00 mm for implants with a diameter of 4 mm in the oversized group and a ...

Background : Implant primary stability depending o...

With increasing stiffness of the bone-implant interface, the vibration frequency of the sensor increases. While RFA is expressed in hertz, implant stability quotient (ISQ) is the scale used to quantify RFA values (range 1–100). Even though RFA has been reported to be a reliable, reproducible, and objective method to measure the stiffness of bone-implant-complex, it has also been reported that R...

Background : Implant primary stability depending o...

Background A reliable option for replacing teeth is the insertion of osseointegrated implants. Dental implant primary stability (DIS) has also been reported to be a fundamental prerequisite for long-term success of dental implants, even though osseointegration has also been achieved without a certain amount of primary stability. Primary stability has been defined as the ability to withstand axi...

Implant primary stability depending on protocol an...

Abstract Background Dental implant primary stability is thought to be a fundamental prerequisite for the long-term survival and success. The aim of this study was to analyze the influence of protocol and insertion mode on dental implant stability ex vivo. One hundred and twenty implants were inserted either manually or machine-driven into porcine mandibles by a standard or over-dimensioned pro...